168 Engine Specification Manual, TPD1522 Issue 2, April 2008
1100 Series, 4 cylinder engines
Electrical
Fuel lift pump
relay
Start aid relay
Fuel lift pump
Standard electric fuel lift
pump with supply from Aux (2)
terminal on ignition switch
Glowplugs
Fuel injection pump
Cold start
advance Cold start
temperature switch
Electric shut-off switch
energise to run
30
50
Starter motor
GStarter relay
B+
D+
W
Resistors optional
100
:
(12v)
12v 2.2W Ignition
warning light
Alternator
G+
+-
-
W
Warning light Warning light
Water temperature
switch
(make on increase of water temperature)
Oil pressure
switch
(break on increase of oil pressure)
Water temperature
sender
Tachometer Water temperature
gauge
Ignition
switch
C
Fuse
Fuse
Fuse
Battery
A
B
Terminal Off Aux Heat Heat / start
Supply
Aux
Start
W/Light
Heat
1
2
3
4
5
A
B
Typical Lucas 128SA ignition switch
Glowplug busbar connector
Deutsch DTHD series
-
+
Instrument light
switch
current rating depends on
auxiliary load
12v system - 50A slow burn fuse
Glow plug fuse rating
Circuit diagram
Starter motors
Note: Resistance of battery cables A, B, and C not to exceed 0.0017 ohm.
Alternators
Model Voltage Solenoid current Max Volt drop in
solenoid circuit
Max pull-in amps Max hold-in amps
P95 12 60 15 0.5
Model Rating Min. cable size for
rating Max circuit Volt drop
A115i
14V 65A 8,50 mm²
0.5V
14V 75A 16,00 mm²
14V 85A 16,00 mm²
A127iR 14V 100A 25,00 mm²
14V 120A 25,00 mm²
pf2
Discount

Em oferta

Pré-visualização parcial do texto

Baixe DIAGRAMA ELÉTRICO MOTOR PERKINS DIESEL e outras Esquemas em PDF para Engenharia Mecânica, somente na Docsity!

168 Engine Specification Manual, TPD1522 Issue 2, April 2008

1100 Series, 4 cylinder engines

Electrical

Fuel lift pumprelay

Start aid relay

Fuel lift pump Standard electric fuel lift pump with supply from Aux (2) terminal on ignition switch

Glowplugs

Fuel injection pump

Cold startadvance Cold start temperature switch Electric shut-off switchenergise to run

30 50 Starter motor G (^) Starter relay

B+ D+ W

Resistors optional 100 : (12v)

12v 2.2W (^) Ignitionwarning light

Alternator

W-+^ G (^) +-

Warning light Warning light

Water temperatureswitch (make on increase of water temperature)

Oil pressureswitch (break on increase of oil pressure)

Water temperaturesender

Tachometer Water temperature gauge

Ignitionswitch

C

Fuse

Fuse Fuse

Battery A

B

Supply^ Terminal^ Off^ Aux Heat Heat / start StartAux W/LightHeat

(^12) (^34) 5

A

B

Typical Lucas 128SA ignition switch

Glowplug busbar connector Deutsch DTHD series

Instrument lightswitch

current rating depends onauxiliary load

12v system - 50A slow burn fuse

Glow plug fuse rating

Circuit diagram

Starter motors

Note: Resistance of battery cables A, B, and C not to exceed 0.0017 ohm.

Alternators

Model Voltage Solenoid current (^) Max Volt drop in Max pull-in amps Max hold-in amps solenoid circuit P95 12 60 15 0.

Model Rating Min. cable size forrating Max circuit Volt drop

A115i

14V 65A 8,50 mm²

0.5V

14V 75A 16,00 mm² 14V 85A 16,00 mm² A127iR 14V 100A 25,00 mm² 14V 120A 25,00 mm²

Engine Specification Manual, TPD1522 Issue 2, April 2008 169

1100 Series, 4 cylinder engines

Suggested cable sizes

Notes:

z Ratings quoted for +30 °C (86 °F) above ambient in free air. For wires bundled in harness, derate values

by 50% assuming all cables are carrying rated current at the same time

z Minimum cable size 1 mm² for mechanical strength rather than current capacity

z All cable runs to be kept as short as possible to minimise Volt drop within a general limit of 0.5 Volt (12V),

unless specified otherwise.

Fuel injection pump data

Cold start aids

Electric fuel lift pump

Cross-section area mm²

Max current amps

Resistance m ohm / m 1,00 16.5 18, 1,25 18.5 14, 1,50 21.0 12, 2,00 25.0 8, 2,50 29.0 7, 3,00 33.0 6, 4,00 39.0 4, 6,00 50.0 3, 8,50 63.0 2, 10,00 70.0 1, 16,00 94.0 1, 25,00 125.0 0,

Pump 12 Volt Delphi DPA Electric shut-off 0.75 amp continuous Cold start device 0.75 amp continuous

Glow-plugs (4 off) Volts

Initial current amps

After 8 seconds amps

After 20 seconds amps

After 60 seconds amps 11.5 84 48 36 34

Nominal system

Max. allowable current draw Peak start-up not to exceed (^) current not to exceedSustained operating Fuse rating 12 Volt 19.0 amp 4.5 amp @ 14.2 Volt 7.5 amp