1. Question : What type of construction material should be
avoided regarding fire protection purposes? K-f (SOLAS II-
2/2.2.3)
ELECTRO TECHNICAL
OFFICER
FACEBOOK
pf3
pf4
pf5
pf8
pf9
pfa
pfd
pfe
pff
pf12
pf13
pf14

Partial preview of the text

Download STCW QUESTIONS AND ANSWERS -2-ETO Electro Technical Officer and more Exams Electrical and Electronics Engineering in PDF only on Docsity!

STCW QUESTIONS AND

ANSWERS - 2 - ETO

MMD QUESTIONS STCW

  1. Question : What type of construction material should be avoided regarding fire protection purposes? K-f (SOLAS II- 2/2.2.3)

ELECTRO TECHNICAL

OFFICER

FACEBOOK

N

Answer: All combustible materials

  1. Question: In case of diesel driven fire pumps, for how long period shall the fuel tank capacity allow the pump to be run at full capacity? (SOLAS II-2/4.3.3.2.3)

Answer: Three hours

  1. Question: What is the maximum allowed suction head for fire pumps? (SOLAS II-2/4.3.3.2.5) Answer: 4.5 meters
  2. Question : In case each hydrant is not fitted with hose and nozzles, what is the requirement? (SOLAS II-2/4.6.1) Answer: Complete interchange ability of hose couplings and nozzles
  3. Question: What number of fire hoses is required for cargo ships of 1000 tons gross and upwards? (SOLAS II-2/4.7.4.1) Answer: One hose for each 30 meter length of ship plus one spare. Hoses for engine and boiler room in addition
  4. Question : What type of nozzles for fire hoses shall be used aboard ships? (SOLAS II-2/4.8.4) Answer: Dual purpose (jet/spray) type incorporating shutoff
  5. Question : What types of gases are not allowed as fire- extinguishing medium for fixed gas fire-extinguishing system aboard ships? (SOLAS II-2/5.1.1)

RECOM DATIO CATEGORIES

FREQUENTLY ASKED

QTIONS AND

ANSWERS-ETO

FREQUENTLY...

ELECTRICAL QUESTIONS

FOR ORAL-ETO

ELECTRICAL...

OBJECTIVE TYPE

QUESTIONS AND

ANSWERS-ETO

OBJECTIVE TYPE...

ELECTRICAL QUESTIONS

AND ANSWERS-MCQ-ETO

QUESTIONS...

ELECTRO TECHNICAL

OFFICER

H aving...

SUBSCRIBE TO

  1. Question : How many power supply emergency sources are required for fire-detection and fire-alarm systems? (SOLAS II- 2/13.1.3) Answer: One
  2. Question : How is the activation of any detector or manually operated call point of fixed fire- detection and fire-alarm systems to be indicated? (SOLAS II-2/13.1.4) Answer: By visual and audible signal at the control panel and indicating units
  3. Question : What other purposes may a fixed fire-detection and alarm system be used for, in addition to fire indication? (SOLAS II-2/13.1.14) Answer: Controlled closing of fire doors
  4. Question : Where shall manually operate call points in fixed fire-detection and alarm systems be located in accommodation spaces? (SOLAS II-2/13.2.1) Answer: At exits and in corridors
  5. Question : Where in accommodation spaces shall smoke detectors be located? (SOLAS II-2/13.2.2) Answer: In stairways, corridors and escape routes
  1. Question : What is the general requirement for closing mechanisms for in- and outlets of all ventilation systems (ships other than passenger ships carrying more than 36 passengers)? (SOLAS II-2/16.9) Answer: Closing must be possible from outside the spaces being ventilated
  2. Question : What is the requirement for stopping arrangements for power-ventilated accommodation spaces, cargo compartments, machinery spaces, service spaces and control stations? Answer: Must be capable of being stopped from an easily accessible position outside the space being served
  3. Question : At what time shall automatic sprinkler, fire- detection and alarm systems be capable of immediate operation? (SOLAS II-2/12.1.1) Answer: At all times
  4. Question : In accommodation the automatic sprinklers shall come into operation within the temperature range: (SOLAS II- 2/12.2.4) Answer: 68 - 79°C
  5. Question : Which of the equipment listed is not included in the fireman's personal equipment? (SOLAS II-2/17.1.1) Answer: Leather safety boots and gloves
  1. Question : "C" class (fire) divisions shall meet one of the listed requirements: (SOLAS II-2/3.5) Answer: Constructed of non-combustible material
  2. Question : Where will the ship's officers find necessary information regarding the ship's fire protection arrangement, fire-detection equipment and fire extinguishing appliances? (SOLAS II-2/20.1) Answer: In permanently exhibited fire control plans
  3. Question : In what language/languages shall the fire control plans/folders (or copies of plans and folders) be? (SOLAS II- 2/20.1) Answer: The Flag State language with copies in English or French
  4. Question : Where shall shore side fire-fighting personnel find necessary information on the ship's fire control in an emergency situation? (SOLAS II-2/20.2) Answer: Copy of the fire control plans/folders to be stored in a watertight prominently marked container outside
  5. Question : Three methods of fire protection regarding internal divisional bulkheading may be adopted in accommodation and service spaces in cargo ships. Which of the given methods do not correspond to Answer: Construction of all internal bulkheads of class "A"

divisions

  1. Question : Fire protection for tankers of 20.000 dwt and upwards consist of different fixed systems and arrangements. Which of the following systems and arrangements do not correspond to the present Should Answer: A fixed sprinkler system at the cargo manifold
  2. Question : Which of the following requirements to fixed foam systems for cargo deck area on tankers do not correspond to present regulations? (SOLAS II-2/61) Answer: Sufficient foam concentrate shall be supplied to ensure at least one hour of foam generation
  3. Questions : Which of the following requirements to inert gas system for oil cargo tanks do not correspond to present regulations? (SOLAS II-2/62.2) Answer: Keep a low pressure in the tanks at all times at sea and in port (periods of gas-freeing excepted)
  4. Question : In an inert gas system audible and visible alarms shall be provided to indicate faulty conditions in the installation. Which of the following conditions do not activate the alarms? (SOLAS II-2/62.19.1) Answer: High air pressure in water seal
  1. Question : Which one of the listed tasks do not necessarily have to be included in onboard training and instruction of crew members? (SOLAS III/18.4 -18.5) Answer: Onboard training and instruction shall be given in addition to regular abandon ship drills
  2. Question : What is a contingency plan for ships?

Answer: Plan for safety preparedness

  1. Question : What does the abbreviation SOLAS mean? Answer: International Convention for the Safety of Lives at Sea
  2. Question : Which international organization is preparing conventions and rules for seafaring nations? Answer: International Maritime Organization (IMO)
  3. Question : Which radio frequency/channels are reserved for emergency communication? Answer: 2182 kHz/VHF channel 16
  4. Question : What is the radio telephone distress signal?

Answer: MAYDAY

  1. Question : What is a "passenger" according to SOLAS

regulations? Answer: Every person other than the Captain and the members of the crew or other persons employed

  1. Question : What is a passenger ship according to SOLAS regulations? Answer: A ship which carries more than 12 passengers
  2. Question : Which of the named ships are not subject to SOLAS regulations?

Answer: Cargo ships of less than 500 tons gross

  1. Question : SOLAS regulations require surveys of ships to be carried out at certain times and at certain intervals. Which of the following surveys apply to passenger ships only? Answer: Periodical survey every 12 months
  2. Question : Which organization or administration is responsible for surveys and inspections of ships, and the issue of Safety Certificates? Answer: Government Authorities of the Flag State
  3. Question : For how long period shall a Passenger Ship Safety Certificate be issued? Answer: A period not exceeding 12 months
  4. Question : A Cargo Ship Construction Certificate will be issued for :
  1. Questions : When cross-flooding arrangements to correct unsymmetrical flooding and excessive heel angels in damaged condition are installed in passenger ships, what is the maximum time allowed for Answer:15 minutes
  2. Question : Automatic shutdown of the inert gas blowers and gas regulating valve shall be arranged in case of faulty condition in the inert gas system. Which of the following conditions has not correct value Answer: High water level in the water seal
  3. Question : Which one of the listed requirements regarding abandon ship and fire drills do not correspond to present regulations? Answer: On all short international voyages, muster of passengers shall take place as soon as possible
  4. Question : Which one of the listed requirements regarding life-saving appliances do not correspond to present regulations? Answer: All prescribed life-saving appliances shall be made of non-combustible or fire retardant material
  5. Question : Which one of the listed requirements regarding buoyant smoke signals do not correspond to present regulations? The buoyant smoke signal shall:

Answer: give a bright red light during the entire emission time

  1. Question : Which one of the listed requirements regarding liferafts do not correspond to present regulations? Every liferaft shall be so constructed that: Answer: it's canopy has viewing ports in all directions
  2. Question : Which one of the listed requirements regarding liferaft equipment do not correspond to present regulations? The normal equipment of every liferaft shall consist of: Answer: thermal protective aids for the number of persons the liferaft is permitted to accommodate
  3. Question : Which one of the listed requirements regarding "week links" for float free arrangements for liferafts do not correspond to present regulations? Week links shall: Answer: release the liferaft at a depth of not more than 4 metros
  4. Question : Which one of the listed requirements regarding the stability of inflatable liferafts do not correspond to present regulations? The stability of inflatable liferafts shall be such that: Answer: in the event of capsizing it will automatically attain a position providing an above water escape
  1. Question : Which one of the listed requirements regarding partially enclosed lifeboats do not correspond to present regulations? The canopy between rigid covers shall be so arranged that: Answer: it has windows to admit sufficient daylight inside the lifeboat with the canopy closed
  2. Question : Which one of the listed requirements regarding self-righting partially enclosed lifeboats do not correspond to present regulations? Self-righting partially closed lifeboats shall have: Answer: sufficient number of pumps and bailers
  3. Question : Which one of the listed requirements regarding enclosures of totally enclosed lifeboats do not correspond to present regulations? The totally enclosed lifeboats shall: Answer: have self-bailing arrangements
  4. Question : Which one of the listed requirements regarding fire protected lifeboats do not correspond to present regulations? Water spray systems shall: Answer: have separate draining pumps of sufficient capacity
  5. Question : Which one of the listed requirements regarding rescue boats do not correspond to present regulations? Rescue boats shall: Answer: have self-bailing arrangements
  1. Question : Which one of the listed requirements regarding rescue boat equipment do not correspond to present regulations? The normal equipment of every rescue boat shall include: Answer: immersion suits for the number of persons the boat is permitted to accommodate
  2. Questions : The training manual shall contain instructions and information in easily understood terms and illustrated wherever possible. Which of the following objects do not have to be explained in detail in the Answer: Donning of fire protection clothing
  3. Question : The training manual shall contain instructions and information in easily understood terms and illustrated wherever possible. Which one of the following objects do not have to be explained in Answer: The use of onboard communication systems
  4. Question : The training manual shall contain instructions and information in easily understood terms and illustrated wherever possible. Which of the following objects do not have to be explained in detail in the Answer: Instruction for emergency repair of fire-fighting equipment
  5. Question : The muster list shall specify details of general alarm signal and also actions to be taken by crew and

Welcome

Thanks to all of readers and friends to love my blog. Hope you

continue your support to my blog as without you friends me

and my SHIPETO BLOG is incomplete. I really appreciate you

all for the efforts you pour to the growth of shipeto. If you have

any doubt about this topic, please comment here. Once again

EXAMINATION OF ELECTRO

TECHNICAL OFFICER- 2015 - ETO-

NO- 1

STCW QUESTIONS AND

ANSWERS

STCW QUESTIONS AND

ANSWERS - 2 - ETO

Manikandan B 9/07/2016 05:23:00 pm - Comments

POST A COMMENT

a heartily THANKS to ALL. Please connect with me:

Facebook | Twitter | Google+ | Linked IN

Subscribe via email

Like the article above? Add your email address to subscribe.

Enter Email address

Submit

This work is licensed under a Creative Commons Attribution 4.0 International License.

About ETO Sitemap

CO PY RIG HT © 2 0 1 6 EL ECTRO TEC HNIC A L O F FICER A L L RIG HT RES ERV ED A RL INA DES IG N