StateofOhioFire AlarmTest-StudyGuideExam Questions and Answers. spacing for smoke detectors or manufactured specs - Correct Answer rule of thumb - 30ft manual pull station height - Correct Answer 3-1/2 to 4-1/2 ft secondary power must turn of within ? seconds on loss of primary supply - Correct Answer 10 seconds manual pull stations must be mounted within ? feet of exits on each floor and spaced up to ? - Correct Answer 5 ft, 200 f
Typology: Exams
1 / 3
This page cannot be seen from the preview
Don't miss anything!
spacing for smoke detectors or manufactured specs - Correct Answer rule of thumb - 30ft manual pull station height - Correct Answer 3 - 1/2 to 4 - 1/2 ft secondary power must turn of within? seconds on loss of primary supply - Correct Answer 10 seconds manual pull stations must be mounted within? feet of exits on each floor and spaced up to ? - Correct Answer 5 ft, 200 ft residential, secondary power supply time - Correct Answer 24 hours in normal, 4 minutes of full alarm commercial, secondary power supply time - Correct Answer 24 hours in normal, 5 minutes of full alarm live voice, secondary power supply time - Correct Answer 24 hours in normal, 15 minutes of full power audible device decibels, public - Correct Answer 75 db minimum or 15 above ambient audible device decibels, private - Correct Answer 45 db or 15 db above ambient smoke detector test frequency, functionality - Correct Answer annually smoke detector test frequency, visual - Correct Answer semi-annually smoke detector test frequency, sensitivity - Correct Answer at installation and every alternate year thereafter smoke detectors, CAN or CANNOT, be supported by their circuit conductors - Correct Answer cannot acceptable to the AHJ (authority having jurisdiction) - Correct Answer Approved alert tone,? ,a live voice instruction - Correct Answer precedes protective covers for manual pull stations must be? and cannot be made on site - Correct Answer listed mirrors or reflectors can be used on what type of smoke detectors - Correct Answer projected beam detectors
maximum sound pressure level in any location is? - Correct Answer 110 decibels trouble signals must be restored in? seconds - Correct Answer 200 seconds door header wall space of? inches or more requires a one detector on either side of the door - Correct Answer 24 inches what can be used to activate (test) smoke detectors - Correct Answer approved aerosols, canned smoke coded alarm systems must repeat the code signal at least? times - Correct Answer 3 smoke detectors can be mounted,? ,in relation to a duct - Correct Answer In a duct, on a duct, or project through a duct smoke detectors, CAN or CANNOT, be recessed in wall - Correct Answer cannot UNLESS listed for such mounting visual appliances are mounted not less than? inches or no greater than? inches - Correct Answer 80 inches, 96 inches (for ceilings less than 86 inches, visual lens mounting height shall be WITHIN 6 inches of the ceiling) audible devices are mounted above the floor no less than? inches and below the ceiling? inches - Correct Answer 90 inches, 6 inches do not mount smoke detectors near? - Correct Answer supply diffusers (rule used to be 3 ft from diffuser) supplementary circuits only need to be? according to the AHJ (authority having jurisdiction) - Correct Answer supervised on sloped ceilings smoke and heat detectors shall be mounted? feet below the peak, measured horizontally - Correct Answer 3 feet provisional fire alarm licenses must be accompanied by an? license at all times - Correct Answer annual license fire alarm systems that cover more than one building must be indicated? - Correct Answer indicated separately partitions within? % of the ceiling height will impede smoke travel across the ceiling - Correct Answer 15 percent alarm and trouble signals, CAN or CANNOT, have the same tone or color - Correct Answer cannot