SPN FMI Description
28 3 % ACCEL POS3 VOLT ABOVE NORM OR SHORT HIGH
28 4 % ACCEL POS3 VOLT BELOW NORM OR SHORT LOW
29 3 % ACCEL POS2 VOLT ABOVE NORM OR SHORT HIGH
29 4 % ACCEL POS2 VOLT BELOW NORM OR SHORT LOW
84 8 TACHOMETER SIGNAL FAILED, VELOCITY SIGNAL DEFECTIVE
91 2 SPEED SET POINT1 (ACCELERATOR PEDAL DEFECTIVE)
91 3 ACCEL PEDAL POS VOLT ABOVE NORM OR SHORT HIGH
91 4 ACCEL PEDAL POS VOLT BELOW NORMAL OR SHORT LOW
91 9 ACCEL PEDAL POS A VALID THROTTLE MSG NOT RCVD
91 11 ERROR HARD SET POINT 1
91 14 ACCEL PEDAL POS THROTTLE SIG VOLT OUT OF RANGE
94 1 FUEL DELIVERY PRESSURE VERY LOW
94 3 FUEL RAIL PRESSURE VOLTAGE OUT OF RANGE HIGH
94 4 FUEL RAIL PRESSURE VOLTAGE OUT OF RANGE LOW
94 10 FUEL DELIVERY PRESSURE DROPPING TOO FAST
94 13 FUEL DELIVERY PRESSURE OUT OF CALIBRATION
94 16 FUEL DELIVERY PRESSURE HIGH
94 17 NO RAIL FUEL PRESSURE
94 18 FUEL DELIVERY PRESSURE LOW
97 0 WATER IN FUEL DETECTED
97 3 WATER IN FUEL INDICATOR VOLTAGE OUT OF RANGE HIGH
97 4 WATER IN FUEL INDICATOR VOLTAGE OUT OF RANGE LOW
97 16 WATER IN FUEL DETECTED
97 31 WATER IN FUEL DETECTED
98 1 OIL LEVEL SWITCH OFF
100 1 ENGINE OIL PRESSURE LOW
100 2 OIL PRESSURE SENSOR DEFECTIVE
100 3 ENGINE OIL PRESS VOLT ABOVE NORM OR SHORT HIGH SOURCE
100 4 ENGINE OIL PRESS VOLT BELOW NORM OR SHORT LOW SOURCE
100 16 ENGINE OIL PRESSURE READING INCORRECT
100 18 ENGINE OIL PRESS LOW
102 2 CHARGE AIR PRESSURE SENSOR DEFECTIVE
105 0 INTAKE MAN1 AIR TEMP HIGH
105 2 CHARGE AIR TEMPERATURE SENSOR DEFECTIVE
105 3 INTAKE MAN1 TEMP VOLT ABOVE NORM OR SHORT HIGH SOURCE
105 4 INTAKE MAN1 TEMP VOLT BELOW NORM OR SHORT LOW SOURCE
105 16 INTAKE MAN1 AIR TEMP HIGH
107 0 AIR FILT DIFF PRESS PLUGGED AIR FILTER DETECTED
107 31 AIR FILT DIFF PRESS PLUGGED AIR FILTER DETECTED
108 12 ATMOSPHERIC PRESSURE
110 0 ENG COOL TEMP HIGH
110 2 COOLANT TEMPERATURE SENSOR DEFECTIVE
110 3 ENG COOL TEMP VOLT ABOVE NORM OR SHORT HIGH SOURCE
110 4 ENG COOL TEMP VOLT BELOW NORM OR SHORT LOW SOURCE
110 15 ENG COOL TEMP HIGH
Page 1 of 4.
PowerView Error Messages
Diagnostic Trouble Codes Text Translations provided by:
PowerView Model PV101 software version Murphy 1.00.06
PowerView Model PV100 software version Murphy 2.09
0710170
12-13-07
Section 78
Note: This list represents text descriptions for faults supported by the PowerView and does not necessarily comply with
SAE J1939. For a specific engine manufacturer’s explanation for codes, please consult the engine’s technical manual.
pf3
pf4

Partial preview of the text

Download SPN FMI Description PowerView Error Messages and more Schemes and Mind Maps Basic Electronics in PDF only on Docsity!

SPN FMI Description

28 3 % ACCEL POS3 VOLT ABOVE NORM OR SHORT HIGH

28 4 % ACCEL POS3 VOLT BELOW NORM OR SHORT LOW

29 3 % ACCEL POS2 VOLT ABOVE NORM OR SHORT HIGH

29 4 % ACCEL POS2 VOLT BELOW NORM OR SHORT LOW

84 8 TACHOMETER SIGNAL FAILED, VELOCITY SIGNAL DEFECTIVE

91 2 SPEED SET POINT1 (ACCELERATOR PEDAL DEFECTIVE)

91 3 ACCEL PEDAL POS VOLT ABOVE NORM OR SHORT HIGH

91 4 ACCEL PEDAL POS VOLT BELOW NORMAL OR SHORT LOW

91 9 ACCEL PEDAL POS A VALID THROTTLE MSG NOT RCVD

91 11 ERROR HARD SET POINT 1

91 14 ACCEL PEDAL POS THROTTLE SIG VOLT OUT OF RANGE

94 1 FUEL DELIVERY PRESSURE VERY LOW

94 3 FUEL RAIL PRESSURE VOLTAGE OUT OF RANGE HIGH

94 4 FUEL RAIL PRESSURE VOLTAGE OUT OF RANGE LOW

94 10 FUEL DELIVERY PRESSURE DROPPING TOO FAST

94 13 FUEL DELIVERY PRESSURE OUT OF CALIBRATION

94 16 FUEL DELIVERY PRESSURE HIGH

94 17 NO RAIL FUEL PRESSURE

94 18 FUEL DELIVERY PRESSURE LOW

97 0 WATER IN FUEL DETECTED

97 3 WATER IN FUEL INDICATOR VOLTAGE OUT OF RANGE HIGH

97 4 WATER IN FUEL INDICATOR VOLTAGE OUT OF RANGE LOW

97 16 WATER IN FUEL DETECTED

97 31 WATER IN FUEL DETECTED

98 1 OIL LEVEL SWITCH OFF

100 1 ENGINE OIL PRESSURE LOW

100 2 OIL PRESSURE SENSOR DEFECTIVE

100 3 ENGINE OIL PRESS VOLT ABOVE NORM OR SHORT HIGH SOURCE

100 4 ENGINE OIL PRESS VOLT BELOW NORM OR SHORT LOW SOURCE

100 16 ENGINE OIL PRESSURE READING INCORRECT

100 18 ENGINE OIL PRESS LOW

102 2 CHARGE AIR PRESSURE SENSOR DEFECTIVE

105 0 INTAKE MAN1 AIR TEMP HIGH

105 2 CHARGE AIR TEMPERATURE SENSOR DEFECTIVE

105 3 INTAKE MAN1 TEMP VOLT ABOVE NORM OR SHORT HIGH SOURCE

105 4 INTAKE MAN1 TEMP VOLT BELOW NORM OR SHORT LOW SOURCE

105 16 INTAKE MAN1 AIR TEMP HIGH

107 0 AIR FILT DIFF PRESS PLUGGED AIR FILTER DETECTED

107 31 AIR FILT DIFF PRESS PLUGGED AIR FILTER DETECTED

108 12 ATMOSPHERIC PRESSURE

110 0 ENG COOL TEMP HIGH

110 2 COOLANT TEMPERATURE SENSOR DEFECTIVE

110 3 ENG COOL TEMP VOLT ABOVE NORM OR SHORT HIGH SOURCE

110 4 ENG COOL TEMP VOLT BELOW NORM OR SHORT LOW SOURCE

110 15 ENG COOL TEMP HIGH

Diagnostic Trouble Codes Text Translations provided by: PowerView Model PV101 software version Murphy 1.00. PowerView Model PV100 software version Murphy 2.

Section 78

Note : This list represents text descriptions for faults supported by the PowerView and does not necessarily comply with SAE J1939. For a specific engine manufacturer’s explanation for codes, please consult the engine’s technical manual.

SPN FMI Description

110 16 ENG COOL TEMP HIGH

111 1 LOW COOLANT LEVEL

120 15 RETARDER OIL TEMPERATURE ABOVE NORMAL

158 2 KEYSWITCH INTERMITTENT

158 17 KEYSWITCH CIRCUIT PROBLEM

171 12 INTERNAL TEMPERATURE

174 0 FUEL TEMP HIGH

174 2 FUEL TEMPERATURE SENSOR DEFECTIVE

174 3 FUEL TEMP VOLT ABOVE NORM OR SHORT HIGH SOURCE

174 4 FUEL TEMP VOLT BELOW NORM OR SHORT LOW SOURCE

174 15 FUEL TEMP HIGH

174 16 FUEL TEMP HIGH

174 31 FUEL TEMP VOLT OUT OF RANGE

177 15 TRANSMISSION OIL TEMPERATURE ABOVE NORMAL

189 31 ENG SPEED DERATE CONDITION EXISTS DUE TO FAULT

190 0 ENGINE OVERSPEED

190 2 ENG SPD DATA ERRATIC, INTERMITTENT OR INCORRECT

190 3 ENG SPD VOLT ABOVE NORMAL OR SHORT HIGH

190 4 ENG SPD VOLT BELOW NORMAL OR SHORT LOW

190 5 ENG SPD CIRCUIT IS OPEN

190 8 ENGINE SPEED SENSOR DEFECTIVE

190 16 ENGINE OVERSPEED

201 2 SPEED SET POINT 2 (HAND THROTTLE DEFECTIVE)

441 0 AUXILIARY TEMPERATURE #1 HIGH (MOST SEVERE)

535 7 CONTROL TRAVEL DIFFERENCE

535 13 AUTO CALIBRATION BOSCH-EDC-PUMP UNSUCCESSFUL

536 12 FEEDBACK RACK POSITION

536 13 REFERENCE FEEDBACK RACK POSITION

563 2 DIGITAL OUTPUT 3 SUPERVISION (STOP SOLENOID)

563 6 EXCESS CURRENT DIGITAL OUTPUT 3 (STOP SOLENOID)

572 2 DIGITAL OUTPUT 6 SUPERVISION

611 3 INJ WIRING SHORTED TO BATTERY

611 4 INJ WIRING SHORTED TO GROUND

620 3 SENSOR VOLT1 (+5VDC)ABOVE NORMAL OR SHORT HIGH

620 4 SENSOR VOLT1 (+5VDC)BELOW NORMAL OR SHORT LOW

627 1 POWER SUPPLY LOW VOLT TO INJECTORS

627 4 POWER SUPPLY INTERRUPTION

629 13 REPROGRAM CONTROLLER ECU PROBLEM

629 19 ECU NOT RECEIVING MSG FROM PUMP

632 2 FUEL SHUTOFF VALVE ERR DETECTED

632 5 FUEL SHUTOFF VALVE NON-FUNCTIONAL

632 11 FUEL SHUTOFF VALVE SOLENOID CKT OPEN OR SHORTED

636 2 ENG POS SENSOR TIMING SIGNAL ERROR

636 8 ENG POS SENSOR TIMING SIGNAL ERROR

636 10 ENG POS SENSOR TIMING SIGNAL ERROR

637 2 TIMING (CRANK) SENSOR TIMING SIGNAL ERROR

Diagnostic Trouble Codes Text Translations provided by: PowerView Model PV101 software version Murphy 1.00. PowerView Model PV100 software version Murphy 2.

SPN FMI Description

970 31 EXT AUX ENG SHUTDOWN SWITCH ACTIVE

971 31 ENG DERATE SWITCH ACTIVATED

1041 2 START SIGNAL MISSING

1041 3 START SIGNAL ALWAYS ACTIVE

1076 0 FUEL INJ PUMP CONT VALVE ERROR

1076 1 FUEL INJ PUMP CONT VALVE ERROR

1076 2 FUEL INJ PUMP CONT VALVE ERROR

1076 3 FUEL INJ PUMP CONT VALVE ERROR

1076 5 FUEL INJ PUMP CONT VALVE ERROR

1076 6 FUEL INJ PUMP CONT VALVE ERROR

1076 7 FUEL INJ PUMP CONT VALVE ERROR

1076 10 FUEL INJ PUMP CONT VALVE ERROR

1076 13 FUEL INJ PUMP CONT VALVE ERROR

1077 7 FUEL INJ PUMP ERROR

1077 11 FUEL INJ PUMP CONT VP44 INPUT VOLT OUT OF RANGE

1077 12 FUEL INJ PUMP CONT VP44 SELF TEST ERROR

1077 19 FUEL INJ PUMP CONT VP44 DETECTED CAN BUS FAILURE

1077 31 FUEL INJ PUMP CONT POWER DERATED

1078 7 FUEL INJ PUMP SPD/POS SENSOR ERROR

1078 11 FUEL INJ PUMP SPD/POS SENSOR ERROR

1078 31 FUEL INJ PUMP SPD/POS VP44 UNABLE TO ACHIEVE TIMING

1079 3 SENSOR VOLT1 (+5VDC)ABOVE NORM OR SHORT HIGH

1079 4 SENSOR VOLT1 (+5VDC)BELOW NORM OR SHORT LOW

1080 3 SENSOR VOLT2 (+5VDC)ABOVE NORM OR SHORT HIGH

1080 4 SENSOR VOLT2 (+5VDC)BELOW NORM OR SHORT LOW

1109 31 ENG PROT SYSTEM APPROACHING SHUTDOWN

1110 31 ENG PROT SYSTEM SHUT ENG DOWN

1347 5 FUEL PUMP ASSY 1 CKT OPEN, SHORTED GROUND OR OVLOAD

1347 7 FUEL PUMP ASSY 1 RAIL PRESSURE CONT MISMATCH

1347 10 FUEL PUMP ASSY 1 LOW FUEL FLOW

1348 5 FUEL PUMP ASSY 2 CKT OPEN, SHORTED GROUND OR OVLOAD

1348 10 FUEL PUMP ASSY 2 LOW FUEL FLOW

1387 1 AUXILIARY PRESSURE #1 LOW (MOST SEVERE)

1485 2 ECU MAIN RELAY PUMP POWER RELAY FAULT

1569 31 ENG PROT TORQ FUEL DERATE LIMIT CONDITION EXIST

2000 6 FUEL INJECTION PUMP CONT VALVE ERROR

2000 13 SECURITY VIOLATION PROPER CONT NOT INSTALLED

2003 31 GENERAL TRANSMISSION FAULT UNKNOWN

Diagnostic Trouble Codes Text Translations provided by: PowerView Model PV101 software version Murphy 1.00. PowerView Model PV100 software version Murphy 2.