Instructions on how to set up Koehler Illumination on a microscope, identify and locate different components in the bright field light path, and safely clean objective lenses. It also discusses the concept of conjugate planes and contrast generation in phase contrast microscopy.
What you will learn
Typology: Lecture notes
1 / 8
This page cannot be seen from the preview
Don't miss anything!
RM Parton revised 2014 - (adapted from a worksheet by Ken Sawin) Questions/Comments: richard.parton@bioch.ox.ac.uk; ian.dobbie@bioch.ox.ac.uk
1) Familiarize yourself with the basic parts of the microscope. 2) Be aware of correct alignment and use of different components in the bright field light path and how they are adjusted to increase contrast 3) How to clean objective lenses safely.
Make a cheek cell prep: stick your finger in your mouth, scrape the side of your cheek and smear it on a slide. You may need to add a drop of PBS (phosphate buffered saline). Put a coverslip on top. You may also look at fission yeast and bacteria to see how thicker (yeast) and smaller (bacteria) can be best observed.
This practical is intended for standard wide field microscopes with a bright field condenser and ideally with different contrast enhancing components. Familiarise yourself with the parts of a basic compound microscope using the diagram (Figures 1 and 2) as a guide. Before you can set up a microscope correctly you need to find the components that need to be adjusted. Find the following components on your microscope: The stage and specimen holder – There are two main forms of microscope: the Upright and the Inverted. With an upright you look down upon the specimen, with an invert you look up at the specimen from below. In both cases the bright field path is “transmitted”, the illumination light from the lamp is collected by the condenser and passes through the specimen (transmitted) to the objective lens on the other the other side. The objective lens and eyepiece - The object is viewed by two lenses, known as the objective lens and eyepiece. This arrangement gives two stages of magnification (hence “compound” microscope). In the first stage the objective lens forms an image of the specimen at the intermediate image plane. In the second this image is viewed by the eyepiece (and the eye). Identify the different objective lenses on the microscope. The bright field condenser lens – Located either under (Upright microscope) or above (Inverted microscope) the microscope stage. When correctly set up, light from the source is focused onto the specimen by the condenser lens, to provide high intensity, even illumination so that the highest powers of the microscope can to be used to optimum effect. Identify the condenser and locate the adjustable components associated with it and what they do.
The condenser or aperture iris - This limits the angle of the light passing from the illumination source through the microscope. The result is reduction in illumination brightness at the specimen and increasing contrast at the expense of resolution due to the fact that resolution is dependent upon the angle of light passing through the microscope). The field iris - This iris restricts the field of illumination at the specimen plane. This increases contrast in the view and reduces photo-damage outside the viewed region of the specimen. Figure 1A – simple compound microscope (bright field path) Figure 2 – Research Microscope (bright field path) http://www.olympusmicro.com/primer/
6. Return to the properly adjusted Koehler illumination. Now remove one of the eyepieces and replace it with a phase telescope or insert a Bertrand lens below the objective if your microscope has one. Either of these will give you a clear view of the back focal plane of the objective, which is conjugate to the condenser aperture plane (This can also be done by simply removing the eyepiece but with a phase telescope/Bertrand lens the back focal plane is magnified and therefore easier to see). Note that the phase telescope itself can be adjusted for the best focus. 7. Looking down the telescope, adjust the aperture diaphragm—open and close it, and see that the edges of the iris open and close, and they should be in sharp focus. Do the same thing with the field diaphragm. Notice that if you change the diameter of the field diaphragm while looking down the phase telescope, you will not see the edges of the field diaphragm. Now repeat the same adjustments of the aperture diaphragm, but look down the eyepiece rather than the phase telescope and observe the same changes in contrast that you observed before. Hopefully by now you will have seen and appreciated the notion of conjugate planes and inverse relationship between the field planes and the aperture planes. Figure 3 A – Koehler Illumination Adapted from “Fundamentals of light Microsocpy” Murphy and Davidson
Figure 3B – Koehler Illumination conjugate planes http://www.microscopyu.com/articles/formulas/formulasconjugate.html
condenser components and phase objectives (identified by Ph and a number e.g. Ph3). The second purpose of Koehler illumination is that phase-contrast and DIC, the two major methods generating contrast from "transparent" specimens with transmitted light, require that the condenser aperture plane is conjugate to a specific plane in the objective—the "back focal plane" (which is what you were looking at with the phase telescope/Bertrand lens).
1. Switch the condenser to a phase setting that matches the objective being used, marked on the objective as Ph-1 or similar. Note that (usually) there is no condenser aperture diaphragm to open or close, as the aperture diameter is now fixed by the fixed-size phase-annulus inside the condenser (Otherwise select the appropriate aperture diaphragm - too far closed and everything will be dark). If
If the microscope has a darkfield position in the condenser it can be interesting to see how this works. If the microscope does not, you can sometimes approximate darkfield by using the condenser phase annulus for a high-power objective (e.g., Ph 3) in combination with a low-power low NA objective (e.g. 10X or 20X Ph 1).
The requirements for DIC are: polarizer, analyzer (the pair of polarising filters before and after the objective , respectively), Wollaston (in the condenser) and Wollaston (at the back of the objective). DIC is the most complicated of all transmitted light methods and the components are the most expensive. Although the principles of DIC are nearly the same on all microscopes, different manufacturers have engineered the components differently. Therefore we won't do a lot of playing around with DIC but rather will just observe the effects of bias retardation, etc. If possible, take out both Wollaston prisms (rotate the turret of the condenser to bright field and remove the prism at the objective) so that you have only the polarisers present (i.e., polariser and analyser). For good DIC the two polarisers should be “crossed” i.e they should be rotated 90 degrees with respect to each other so very little light gets through. If you have a de Sénarmont-type DIC (rotatable polarizer), rotate this and observe the effects on the brightness of the image. Otherwise, or in addition, slide the analyser in and out of position to observe the effects on the brightness of the image.
Always keep fresh lens tissue by the microscope. ALWAYS. This will encourage people to use it regularly; this is a lot cheaper than replacing objectives. Lens tissue is very cheap, and good value for money. Kimwipes, paper towels, toilet paper, must NOT be used EVER.
Know the difference between the oil and non-oil objectives on your microscope. If you are aware of this, and also of the fact that working distances for high NA "dry" objectives (e.g., 40X/0.9 NA) can be quite short, you are very unlikely to get oil onto a dry objective. Wiping the objective: This is especially important on inverted microscopes, since excess oil can leak down (by gravity) into the objective itself, through the gap used for the spring- loading. I usually take a piece of fresh lens tissue and fold it over twice, so that it has 4 layers. Then I wipe the region around the glass very gently, to soak up oil. The idea of the four layers is that it prevents any oils from your fingers from getting through. Then I use a fresh piece (folding again) and gently touch the front lens to remove any oil from there. The main goal is to avoid contacting the lens with the same region of tissue twice, since the tissue could contain small bits of dust that could scratch the lens. Cleaning the objective front lens: The idea is to use a fairly powerful solvent, but to minimize the time that the lens is exposed to solvent by wicking it away even as it is applied. The reason is that many solvents can react with the cement that holds the lenses together, and eventually ruin the objective, so there is a compromise between using a strong solvent and minimizing its exposure to the lens. If the solvent is highly volatile, this can help to minimize exposure time. I use chloroform, but you can also use acetone or isopropanol. Isopropanol is less harsh but might not remove all contaminants and is less volatile, so will stay on the lens longer. Take the objective off of the microscope and put it upright on the bench. Examine it using an inverted eyepiece as a magnifying glass. Alternatively, some people use a dissection scope. If the objective front lens is covered in media, cells or agar then it should first be cleaned with water, since the use of solvents will fix the crud onto the objective, after which you may never get it off. Assuming that you want to get rid of just oil and dust, have a bottle of acetone nearby. Take a piece of lens tissue and hold it over the objective from lens. Using a rubber bulb and a glass pasteur-pipette, drop one or two drops of ether onto the lens tissue above the front lens. As you are doing this, wick it away by drawing the lens tissue across the front lens. Look to see if all of the oil is gone. If not, repeat the procedure, with either fresh lens tissue or a region of tissue that hasn't yet been used. Cleaning the eyepieces: make a "fresh brush" by licking the ends of lens tissue and wrapping it around a stick, and licking and sealing the end, and then tearing it off to make virgin fibres that can be used to touch the glass. One the eyepieces, the major culprit is usually dust and also a bit of oil from your eyelashes. Quite often this can be cleaned with just a bit of water. You could squirt a little on the brush, and gently wipe it around. It is always better to wet the brush lightly rather than squirt a lot of liquid onto the glass and then try to wipe it all off, since it could seep into unwanted places. Mascara is very easy to get on and very hard to clean of eyepieces. If you are using a microscope try not to wear mascara. Do not do apply these cleaning methods to anything that is coated with something sensitive, such as a fluorescence interference filter! Antireflection coatings should tolerate water— but many interference filters will be ruined by water. If you do need to clean them then talk to the manufacture about how best to clean them. The best solution is not to get fingerprints on them in the first place.