Docsity
Docsity

Prepare for your exams
Prepare for your exams

Study with the several resources on Docsity


Earn points to download
Earn points to download

Earn points by helping other students or get them with a premium plan


Guidelines and tips
Guidelines and tips

SDI Manual of Construction with Steel Deck: Exercises and Questions, Exams of Environmental Science

A series of multiple-choice questions and answers related to the construction of steel decks. It covers various aspects of steel deck installation, including types of decks, attachment methods, safety procedures, and weight limitations. Useful for students and professionals seeking to understand the practical aspects of steel deck construction.

Typology: Exams

2024/2025

Available from 11/16/2024

Shantelle
Shantelle ๐Ÿ‡บ๐Ÿ‡ธ

5

(2)

3K documents

1 / 18

Toggle sidebar

This page cannot be seen from the preview

Don't miss anything!

bg1
SDI Manual of Construction with
Steel Deck, 3rd Edition
_____ must be tightly connected to prevent opening during concrete
pouring.
A. Soft spots
B. Floor deck
C. Concrete
D. Side laps - โœ” โœ” D. Side laps
41
_____ steel deck would have a designation of 3" x 8" (DR)?
A. Roof
B. Composite
C. Form
pf3
pf4
pf5
pf8
pf9
pfa
pfd
pfe
pff
pf12

Partial preview of the text

Download SDI Manual of Construction with Steel Deck: Exercises and Questions and more Exams Environmental Science in PDF only on Docsity!

SDI Manual of Construction with

Steel Deck, 3rd Edition

_____ must be tightly connected to prevent opening during concrete pouring.

A. Soft spots B. Floor deck C. Concrete D. Side laps - โœ” โœ” D. Side laps

_____ steel deck would have a designation of 3" x 8" (DR)?

A. Roof B. Composite C. Form

D. Cellular - โœ” โœ” A. Roof

______ is responsible to provide fall protection during deck erecting operations.

A. The employer B. The customer C. The foreman D. The inspector - โœ” โœ” A. The employer

_____ deck can be used to provide a chase for electrical distribution.

A. Composite B. Roof C. Form D. Cellular - โœ” โœ” D. Cellular

Which of the following types of deck would have a designation 1-1/2 x 6 (WR)?

B. Roof C. Form D. Cellular - โœ” โœ” D. Cellular

Which of the following types of deck would have a designation 1-1/2 x 6 (WR)?

A. Roof B. High profile C. Low profile D. Form - โœ” โœ” A. Roof

Which one of the following is not a proper method to attach steel decking?

A. Air/Power driven fasteners B. Self drilling screws C. Welding

D. Adhesive - โœ” โœ” D. Adhesive

1-1/2" x 6" composite floor deck has a weight range of _____.

A. 2 psf - 4 psf B. 2 psf - 5 psf C. 2 psf - 7 psf D. None of the above - โœ” โœ” B. 2 psf - 5 psf

A ____ should be used at reasonable intervals to assure proper alignment of deck panels.

A. Story pole B. Snap chalk line C. Ley line D. Guideline - โœ” โœ” B. Snap chalk line

A working area at least _____ feet wide should be established around or along each bundle so that the bundle can safely be accessed.

A. 20 B. 15 C. 12 D. 10 - โœ” โœ” C. 12

Bundles should always be hoisted by the strapping and should always be placed tag side up.

A. True B. False - โœ” โœ” B. False

Cellular deck is always furnished galvanized or phosphatized.

A. True B. False - โœ” โœ” B. False

Deck bundle weight is limited to a maximum of _____ pounds for deck to be applied to joists.

A. 5, B. 4, C. 4, D. 3,000 - โœ” โœ” C. 4,

Deck is typically attached to the building frame with all of the following except:

A. 30

B. 40

C. 50

D. 60 - โœ” โœ” C. 50

Form deck finishes are typically furnished _____.

A. Uncoated B. Prime painted C. Galvanized D. All of the above - โœ” โœ” D. All of the above

Roof deck can be butted (or lapped more than 2") to solve field fit problems.

A. True B. False - โœ” โœ” A. True

Roof deck is typically installed to end lap approximately _____ inches over supports.

A. 6 B. 4 C. 2 D. 2-1/2 - โœ” โœ” C. 2

Roof deck is typically installed to end lap approximately _____ over supports.

A. 1" B. 1.5"

C.

D. #16 - โœ” โœ” B.

The standard maximum bundle weight for steel decking is _____ pounds.

A. 1000 B. 2000 C. 3000 D. 4000 - โœ” โœ” D. 4000

Weld washers are not recommended for deck thicknesses of _____ inches thick and greater.

A. 0. B. 0.

C. 0.

D. 0.025 - โœ” โœ” C. 0.

The maximum size penetration that can be made in roof deck without the need of reinforcing is _____.

A. 4" B. 6" C. 8" D. 10" - โœ” โœ” B. 6"

Weld washers are recommended for metal thickness less than _____ gage.

A. 20 B. 22

Welding side laps is not recommended for deck type _____ gage or lighter.

A. 24 B. 22 C. 20 D. 18 - โœ” โœ” B. 22

When attaching steel deck with a side lap connection, a good weld will have _____ or more of its perimeter working.

A. 7/ B. 1/ C. 1-1/ D. 9/8 - โœ” โœ” A. 7/

When placing deck, workers should maintain a safe distance of about _____ feet from the end of the deck unit.

A. 20 B. 16 C. 12 D. 6 - โœ” โœ” D. 6

When placing steel deck. Workers should maintain a safe distance of _____ feet from the end of the deck unit.

A. 2 B. 4 C. 6 D. 8 - โœ” โœ” C. 6