RETA CARO Exam Latest Version 2025 2026| Questions and Accurate Answers | Verified Soluti, Exams of Refrigeration and Air Conditioning

RETA CARO Exam Latest Version 2025 2026| Questions and Accurate Answers | Verified Solution 100% Which refrigerant has the highest mass flow requirement at the same evaporator and condensing temperature? CFC-12 which refrigerant is the first to be phased out by Montreal Protocol CFC-12 As the ratio between the evaporator and condensing pressure increases the theoretical discharge temperature increases

Typology: Exams

2024/2025

Available from 06/29/2025

high-flyer
high-flyer 🇺🇸

5

(3)

450 documents

1 / 4

Toggle sidebar

This page cannot be seen from the preview

Don't miss anything!

bg1
RETA CARO Exam Latest Version 2025-
2026| Questions and Accurate Answers |
Verified Solution 100%
Which refrigerant has the highest mass flow requirement at the same evaporator and condensing
temperature?
CFC-12
which refrigerant is the first to be phased out by Montreal Protocol
CFC-12
As the ratio between the evaporator and condensing pressure increases
the theoretical discharge temperature increases
Under the Montreal Protocol
as long as a technician does not perform work on the refrigerant containing portions of a system they do
not need to be certified
Refrigerant leaks are detected using
Either a sulfur stick on ammonia or electronic leak detector for CFCs or HCFCs
the primary reason for concern about CFC-12 concentration in an engine room is
pf3
pf4

Partial preview of the text

Download RETA CARO Exam Latest Version 2025 2026| Questions and Accurate Answers | Verified Soluti and more Exams Refrigeration and Air Conditioning in PDF only on Docsity!

RETA CARO Exam Latest Version 2025-

2026| Questions and Accurate Answers |

Verified Solution 100%

Which refrigerant has the highest mass flow requirement at the same evaporator and condensing temperature? CFC- 12 which refrigerant is the first to be phased out by Montreal Protocol CFC- 12 As the ratio between the evaporator and condensing pressure increases the theoretical discharge temperature increases Under the Montreal Protocol as long as a technician does not perform work on the refrigerant containing portions of a system they do not need to be certified Refrigerant leaks are detected using Either a sulfur stick on ammonia or electronic leak detector for CFCs or HCFCs the primary reason for concern about CFC-12 concentration in an engine room is

oxygen deprivation the published lower explosive limit for ammonia is 16% under normal conditions an ammonia vessel should only be filled to what percentage 80% which refrigerant can be detected by its odor even in low concentrations R- 717 Which refrigerant would have the lowest condensing pressure at 95 Degrees F CFC- 11 A cartridge type gas mask may legally be used for personal protection when the type of the hazard is known and the concentration is known a vapor can NOT be subcooled what kind of measure is a to of refrigeration a rate of heat transfer in BTUs per Unit of time

Superheated refrigerant can only be? Vapor Saturated refrigerant can be what? A liquid, vapor or a combination of the two What do you multiply the mass flow rate (lbs./min) by to determine the vapor flow rate through the compressor Specific volume (cubic ft./lbs) Three factors to consider when choosing a refrigerant are Cost, available, and safety One positive characteristic of halocarbon refrigerant is They are usually not flammable Which refrigerant requires the largest compressor displacement per ton R-134a