PSI NATIONAL HOME INSPECTOR PRACTICE EXAM 2024, Exams of Real Estate Management

PSI NATIONAL HOME INSPECTOR PRACTICE EXAM 2024 QUESTIONS AND ANSWERS WITH COMPLETE SOLUTION

Typology: Exams

2024/2025

Available from 01/21/2025

Andreas-best
Andreas-best 🇬🇧

726 documents

1 / 10

Toggle sidebar

This page cannot be seen from the preview

Don't miss anything!

bg1
PSI NATIONAL HOME INSPECTOR PRACTICE EXAM 2024
QUESTIONS AND ANSWERS WITH COMPLETE SOLUTION
"You complete your inspection and deliver the report to the client. The seller calls and asks what you
found on the inspection. What is your response?
A) Explain in detail what you found.
B) You are not allowed to discuss your findings with them.
C) Tell them that nothing serious was found and not to worry.
D) You may discuss your findings if they are willing to fix any problems. - CORRECT ANSWER B) You are
not allowed to discuss your findings with them."
"What type of foundation has a large amount of reinforced steel and is known as a floating foundation?
A) Pier-and-grade beam foundation system
B) "Inverted T" spread footing foundation
C) "Battered" foundation footing system
D) Mat foundation slab - CORRECT ANSWER D) Mat foundation slab"
"The purpose of anchor bolts in a sill plate is to:
A) Prevent movement.
B) Prevent wall racking.
C) Prevent wall collapse.
D) Prevent wall misalignment. - CORRECT ANSWER A) Prevent movement."
"Home inspectors report receptacles with reversed polarity as potentially hazardous because:
A) They contribute to the overheating of the receptacle.
B) They increase the shock likelihood at connected equipment.
C) Single phase appliance motors will run backwards.
D) They trip ground fault circuit interrupter outlets. - CORRECT ANSWER B) They increase the shock
likelihood at connected equipment."
"The term "wet vent" refers to a:
A) Vent that traps water and therefore stays wet.
B) Vent located above the roof line and exposed to rain.
C) Vent that runs outside an exterior wall.
D) Waste line that also functions as a vent. - CORRECT ANSWER D) Waste line that also functions as a
vent."
1 | P a g e
pf3
pf4
pf5
pf8
pf9
pfa

Partial preview of the text

Download PSI NATIONAL HOME INSPECTOR PRACTICE EXAM 2024 and more Exams Real Estate Management in PDF only on Docsity!

PSI NATIONAL HOME INSPECTOR PRACTICE EXAM 2024

QUESTIONS AND ANSWERS WITH COMPLETE SOLUTION

"You complete your inspection and deliver the report to the client. The seller calls and asks what you found on the inspection. What is your response? A) Explain in detail what you found. B) You are not allowed to discuss your findings with them. C) Tell them that nothing serious was found and not to worry.

D) You may discuss your findings if they are willing to fix any problems. - CORRECT ANSWER B) You are

not allowed to discuss your findings with them." "What type of foundation has a large amount of reinforced steel and is known as a floating foundation? A) Pier-and-grade beam foundation system B) "Inverted T" spread footing foundation C) "Battered" foundation footing system

D) Mat foundation slab - CORRECT ANSWER D) Mat foundation slab"

"The purpose of anchor bolts in a sill plate is to: A) Prevent movement. B) Prevent wall racking. C) Prevent wall collapse.

D) Prevent wall misalignment. - CORRECT ANSWER A) Prevent movement."

"Home inspectors report receptacles with reversed polarity as potentially hazardous because: A) They contribute to the overheating of the receptacle. B) They increase the shock likelihood at connected equipment. C) Single phase appliance motors will run backwards.

D) They trip ground fault circuit interrupter outlets. - CORRECT ANSWER B) They increase the shock

likelihood at connected equipment." "The term "wet vent" refers to a: A) Vent that traps water and therefore stays wet. B) Vent located above the roof line and exposed to rain. C) Vent that runs outside an exterior wall.

D) Waste line that also functions as a vent. - CORRECT ANSWER D) Waste line that also functions as a

vent."

"EIFS is a siding material that: A) Is used in commercial buildings only. B) Looks like stucco but lacks a wire mesh. C) Can be installed on top of a modified bitumen membrane.

D) Can be installed on top of a masonry surface. - CORRECT ANSWER B) Looks like stucco but lacks a

wire mesh." "The joints on the exterior of the brick chimney should be: A) Concaved. B) Raked. C) Open.

D) Closed. - CORRECT ANSWER A) Concaved"

"When a water heater thermostat is set at 140 ° F or higher, a ______ should be installed to temper the water. A) Temperature probe B) Mixing probe C) Mixing valve

D) Temper valve - CORRECT ANSWER C) Mixing valve"

"In a forced air furnace, the burners are used to generate heat in the: A) Heat exchanger. B) Draft diverter. C) Flue.

D) Plenum. - CORRECT ANSWER A) Heat exchanger."

"While inspecting a crawl space, you should probe for decay if the _________ is dark in appearance. A) King joist B) Floor joist C) Masonry wall

D) Bearing wall - CORRECT ANSWER B) Floor joist"

"Which statement BEST describes the action a home inspector should take when a safety issue is found in a home? A) Determine the degree of immediacy, and report to the appropriate parties. B) Explain verbally to the client, but do not include in a written report. C) Repair the problem when possible.

"Two roof trusses passing above an interior hallway have been cut to install a pull-down attic ladder. There is no cracking or indication of distress in the walls or ceilings. Which of the following is the MOST appropriate action? A) This is not a concern since this is no indication of distress. B) This is beyond the scope of an inspection and does not need to be reported. C) The inspector can evaluate the remaining pieces of the trusses as if they were site-built.

D) The inspector should recommend this situation be referred to a structural engineer. - CORRECT

ANSWER D) The inspector should recommend this situation be referred to a structural engineer."

"While inspecting a one-year-old house, slab on grade, you observe hairline cracks in the concrete floor with no vertical displacement. This indicates: A) Insufficient reinforcement. B) Unstable subsoil. C) Overhydrated concrete.

D) Normal plastic shrinkage. - CORRECT ANSWER D) Normal plastic shrinkage."

“Which of the following describes partial vapor pressure? A) Water vapor has a tendency to disperse itself equally in the available air. B) Water vapor causes new homes to require house wrap. C) Water vapor is common with forced induction natural gas furnaces.

D) Water vapor is an indication of sick house syndrome. - CORRECT ANSWER A) Water vapor has a

tendency to disperse itself equally in the available air." "In order for soffit vents to operate properly, there MUST be: A) A clear air channel between the roof boards and the insulation. B) An absence of insect, bee, and bird nests. C) Vents on both ends on the outside.

D) Continuous vent strips on the length of the soffit. - CORRECT ANSWER A) A clear air channel

between the roof boards and the insulation." "When inspecting a home, the seller of the property has made the statement that all the appliances are in working order. As an inspector, you should: A) Take the seller's information for granted, and do not test any appliances. B) Say nothing about the appliance in the report. C) If you inspect appliances, tell your client that you will check them out.

D) Assume the seller is hiding a problem, and report your suspicion to the client. - CORRECT ANSWER

C) If you inspect appliances, tell your client that you will check them out."

"You observe approximately 12 inches of loose fill fiberglass insulation in an attic space. You advise the client that the "R" value is approximately: A) R11. B) R13. C) R19.

D) R30. - CORRECT ANSWER D) R30."

"To measure carbon monoxide, you should use a(n): A) OC detector. B) OC2 detector. C) CO2 detector.

D) CO detector. - CORRECT ANSWER D) CO detector."

"The MINIMUM width of stairways (not considering railings) is: A) 27 inches. B) 36 inches. C) 42 inches.

D) 44 inches. - CORRECT ANSWER B) 36 inches."

"Generally, which type of item is NOT included in a home inspection? A) Unsafe B) Defective C) Not present

D) Cosmetic - CORRECT ANSWER D) Cosmetic"

"Water is dripping from the cold water pipes above a gas water heater. This might be caused by: A) Exhaust spillage. B) Short cycling. C) A cold start.

D) Overfiring. - CORRECT ANSWER A) Exhaust spillage."

"A drainage tile can be recognized BEST as a: A) Curved clay-tile assembly installed along the headwall of a dormer in lieu of stepped flashing. B) Pipe set in gravel running continuously along the exterior of a building's foundation footings. C) Ceramic-tile washboard installed at a laundry sink to divert water into the sink.

"Which of the following is TRUE with regard to powder post beetles? A) They are normally detected by listening for the "clicking" sound they make when chewing on wood. B) Their presence is confirmed when shelter tubes are reconstructed after damage. C) They create exit holes which are approximately 1/16 inch in diameter.

D) They are known as "deathwatch" beetles. - CORRECT ANSWER C) They create exit holes which are

approximately 1/16 inch in diameter." "During your inspection you see small white insects. What do you say to your clients? A) Do not say anything. B) There are termites in this property. C) There is damage to the structure due to an insect infestation.

D) Suggest obtaining the services of a pest control operator. - CORRECT ANSWER D) Suggest obtaining

the services of a pest control operator." "All of the following statements make an assumption that can normally be determined by routine home inspection procedures EXCEPT the: A) Furnace was operated and found in normal working order. B) Siding was visually inspected, and no conditions requiring repair were noted. C) House is in sound structural condition.

D) House appears to have a dry basement. - CORRECT ANSWER C) House is in sound structural

condition." "You see during your inspection that the air conditioning system has supply registers in each bedroom, but only one large return register is located in the center hallway. Your FIRST course of action would be to: A) Recommend to your client that return ducts be installed in each bedroom. B) Check to see if the bedroom doors are undercut at the bottom. C) Report that the life of the A/C equipment will be reduced.

D) Report that the A/C system will not work well. - CORRECT ANSWER B) Check to see if the bedroom

doors are undercut at the bottom." "The MOST common cause of chimney flue liner deterioration is: A) Rust. B) Condensation. C) Bad cement.

D) High wind. - CORRECT ANSWER B) Condensation."

"Which of the following is a safety mandate in a remodeled home where a hydro-massage bathtub has been added? A) The faucets must be at the drain end. B) The tub area must have a venting fan. C) There must be a vacuum breaker.

D) There must be a ground fault circuit interrupter. - CORRECT ANSWER D) There must be a ground

fault circuit interrupter." "The following plumbing fixture valves should all be operated EXCEPT: A) Shut-off valves. B) Hose bibbs. C) Sink faucets.

D) Showers and tubs. - CORRECT ANSWER A) Shut-off valves."

"While inspecting the furnace you detect very high levels of carbon monoxide at the supply air registers. You should: A) Advise that everyone run out of the house for safety. B) Immediately shut off the main gas valve to disable the unit. C) Open windows, shut down systems, and advise immediate evaluation by an HVAC contractor.

D) Explain that the unit will need servicing in the future to prolong its life. - CORRECT ANSWER C)

Open windows, shut down systems, and advise immediate evaluation by an HVAC contractor." "To avoid scalding injuries, heating elements should be set to: A) 100°F. B) 110°F. C) 120°F.

D) 130°F. - CORRECT ANSWER C) 120°F."

"The proper slope on a drain line is: A) 1/4 inch to 1/2 inch per foot. B) Less than 1/4 inch per foot. C) 1 inch per foot.

D) No slope. - CORRECT ANSWER A) 1/4 inch to 1/2 inch per foot."

"You are inspecting a home built in 1996. In the garage you observe the walls are covered with 1/4 inch hardboard panels. You advise the client that: A) The walls do not meet crush resistance requirements and should be replaced.

"You are approached by a real estate agent/broker to advertise in their office brochure for a fee. In turn, they will promote your firm as a preferred vendor and recommend you. You should: A) Accept since it is an acceptable method of marketing. B) Accept only if there is nothing which precludes your responsibility to your clients. C) Refuse because such an arrangement may compromise your integrity.

D) Refuse since it is a violation of ethical practice. - CORRECT ANSWER D) Refuse since it is a violation

of ethical practice." "During an inspection of a gas dryer, you observe no exhaust vent. Your report should: A) Recommend installing a metal dryer duct vented to the exterior. B) Recommend installing a flexible plastic dryer duct vented to the exterior. C) Indicate a code violation and state that corrective action should be taken.

D) Indicate that this is not a problem because a stocking is placed above the opening to trap lint. -

CORRECT ANSWER A) Recommend installing a metal dryer duct vented to the exterior."

"Soil surface adjacent to the foundation should be: A) Sealed to prevent water entry. B) Compacted to provide foundation support. C) Covered by granular soil.

D) Sloped away to provide proper drainage. - CORRECT ANSWER D) Sloped away to provide proper

drainage." "