This standard shall apply to ______ intended to carry water for fire service
mains - correct answers Combined Service Mains
Working plans shall be submitted for approval to the _____ before any
equipment is installed or remodeled. - correct answers AHJ
____ shall not be used - correct answers Pressure-Regulating devices
______ shall not be installed in the piping from the fire department
connection to the fire service main - correct answers Control Valves
_____ shall be permitted in the system downstream of the fire department
connection - correct answers Control Valves
When more than one water supply exists, a ___________ shall be installed
in each connection - correct answers Check Valve
All check valves shall have a ________ installed upstream and downstream
of the check valve. - correct answers Control Valve
pf3
pf4
pf5

Partial preview of the text

Download NFPA 24 Test (TFM10) Exam Questions and Answers (Latest Update 2023-2024) (30 Qs) and more Exams Nursing in PDF only on Docsity!

(Latest Update 2023-2024) (30 Qs)

This standard shall apply to ______ intended to carry water for fire service mains - correct answers ✅Combined Service Mains Working plans shall be submitted for approval to the _____ before any equipment is installed or remodeled. - correct answers ✅AHJ ____ shall not be used - correct answers ✅Pressure-Regulating devices ______ shall not be installed in the piping from the fire department connection to the fire service main - correct answers ✅Control Valves _____ shall be permitted in the system downstream of the fire department connection - correct answers ✅Control Valves When more than one water supply exists, a ___________ shall be installed in each connection - correct answers ✅Check Valve All check valves shall have a ________ installed upstream and downstream of the check valve. - correct answers ✅Control Valve

(Latest Update 2023-2024) (30 Qs)

A post indicator valve installed not less than____ from the building - correct answers ✅40 ft Where post indicator valves are used, they shall be set so that the top of each post is _______ above final grade - correct answers ✅32-40 inches Supervision of underground gate valves with roadway boxes shall ____________ - correct answers ✅not be required The connection from the hydrant to the main shall ___________ - correct answers ✅not be less than 6 inches Hydrants shall be located _________ from the buildings to be protected - correct answers ✅not less than 40 ft Hydrants shall be installed on __________ - correct answers ✅flat stones, concrete slabs, or other approved material

(Latest Update 2023-2024) (30 Qs)

Private fire service mains installed under driveways or roadways shall be buried at a ______________ - correct answers ✅minimum depth of 36 inches Where private fire mains extend more than 10 ft into the building, they shall be ___________ - correct answers ✅run in a covered trench Thrust blocks shall be concrete of a mix not leaner than ______________ - correct answers ✅1 part cement, 2 1/2 parts sand, and 5 parts stone Rods shall be _____________ - correct answers ✅not less than 5/8 in diameter After installation, rods, nuts, bolts, washers, clamps, and other restraining devices _____________________ - correct answers ✅shall be cleaned and thoroughly coated with a bituminous or other acceptable corrosion- retarding material Pipe shall be _____________________ - correct answers ✅restrained at the bottom of a hill and at any lateral or vertical turns

(Latest Update 2023-2024) (30 Qs)

Bell ends shall be __________ - correct answers ✅facing uphill The flushing operation shall continue until water flow is verified to be ___________ - correct answers ✅clear of debris The installing contractor shall be responsible for _______________________

  • correct answers ✅completing and signing the contractors material and test certificates All piping shall be hydrostatically tested at ____________________________
  • correct answers ✅gauge pressure of 200 psi or 50 psi above working pressure for 2 hours Flow required to produce velocity of __________ in pipes - correct answers ✅10 ft/sec ______________ do not include drain valves, check valves, or relief valves - correct answers ✅control valves