NERC Certification Exam Questions | Actual Questions and Answers Latest Updated 2024/2025 (Graded A+) Which of the following represents a virtual tie-line updated in real time? - ✔✔pseudo-tie Balancing Areas shall analyze forecasted generation availability and reserve levels, and inform their reliability coordinators of actual or potential generation deficiencies each: - ✔✔day Balancing authorities that share jointly owned generation must include their share of the uni

Typology: Exams

2024/2025

Uploaded on 06/11/2025

Intellvision
Intellvision 🇺🇸

5

(21)

3.7K documents

1 / 2

Toggle sidebar

This page cannot be seen from the preview

Don't miss anything!

bg1
NERC Certification Exam Questions | Actual Questions and Answers Latest
Updated 2024/2025 (Graded A+)
Which of the following represents a virtual tie-line updated in real time? - ✔✔pseudo-tie
Balancing Areas shall analyze forecasted generation availability and reserve levels, and inform their
reliability coordinators of actual or potential generation deficiencies each: - ✔✔day
Balancing authorities that share jointly owned generation must include their share of the unit governor
droop response into their respective frequency bias setting if the energy is scheduled as a: - ✔✔dynamic
schedule
A balancing authority's frequency bias contribution is 30 MW / 0.1 Hz. What is the balancing authority's
frequency response due to the external loss of 1,000 MW generator which causes system frequency to
decline to 59.95 Hz? - ✔✔15 MW
A system operator experiences a system failure of AGC and ACE functions. The operator's first priority
should be to: - ✔✔manually calculate ACE and adjust generation to maintain scheduled interchange
Interruptible loads may be dispatched to alleviate: - ✔✔capacity deficiency
Telecommunication facilities that link with interconnected systems should be available to the system
operator: - ✔✔on a continuous basis
Initial response to frequency decline occurs from what source? - ✔✔frequency response characteristic
One way to obtain load relief during a capacity emergency would be to: - ✔✔reduce voltage
1
pf2

Partial preview of the text

Download NERC Certification Exam Questions | Actual Questions and Answers Latest Updated 2024/2025 and more Exams Engineering in PDF only on Docsity!

NERC Certification Exam Questions | Actual Questions and Answers Latest

Updated 2024/2025 (Graded A+)

Which of the following represents a virtual tie-line updated in real time? - ✔✔pseudo-tie Balancing Areas shall analyze forecasted generation availability and reserve levels, and inform their reliability coordinators of actual or potential generation deficiencies each: - ✔✔day Balancing authorities that share jointly owned generation must include their share of the unit governor droop response into their respective frequency bias setting if the energy is scheduled as a: - ✔✔dynamic schedule A balancing authority's frequency bias contribution is 30 MW / 0.1 Hz. What is the balancing authority's frequency response due to the external loss of 1,000 MW generator which causes system frequency to decline to 59.95 Hz? - ✔✔15 MW A system operator experiences a system failure of AGC and ACE functions. The operator's first priority should be to: - ✔✔manually calculate ACE and adjust generation to maintain scheduled interchange Interruptible loads may be dispatched to alleviate: - ✔✔capacity deficiency Telecommunication facilities that link with interconnected systems should be available to the system operator: - ✔✔on a continuous basis Initial response to frequency decline occurs from what source? - ✔✔frequency response characteristic One way to obtain load relief during a capacity emergency would be to: - ✔✔reduce voltage

When a system's anticipated operating conditions threaten the reliability of the interconnection, the system strength should be examined and: - ✔✔other systems informed through predetermined communication paths