A set of review questions and answers for the ncleac advanced certification exam. It covers various topics related to contact lens fitting, including lens specifications, corneal conditions, and lid conditions. Designed to help students prepare for the exam by providing practice questions and explanations.
Typology: Exams
1 / 225
This page cannot be seen from the preview
Don't miss anything!
Course Title and Number: NCLEAC Advanced Certification Exam Exam Title: Advanced Certification Exam Exam Date: Exam 2025- 2026 Instructor: ____ [Insert Instructor’s Name] _______ Student Name: ___ [Insert Student’s Name] _____ Student ID: ____ [Insert Student ID] _____________
Time: - ____ Hours: ___ Minutes Instructions:
🤔Hit Me UP__ Inbox Open 24/7 – 365 …...!!!! 🤔 Chat with us here : 🤔 Hybridgrades101@gmail.com
Read All Instructions Carefully and Answer All the Questions Correctly Good Luck: -
🤔Hit Me UP__ Inbox Open 24/7 – 365 …...!!!! 🤔 Chat with us here : 🤔 Hybridgrades101@gmail.com When adding a spherical over-refraction to a bitoric lens, it must be added to both meridians Example: -1.00 / -4. -1.00 / -1. -2.00 / -5.
🤔Hit Me UP__ Inbox Open 24/7 – 365 …...!!!! 🤔 Chat with us here : 🤔 Hybridgrades101@gmail.com Dimple veil staining may occur when there is either a steeper or flatter than recommended lens to cornea relationship. Air bubbles become trapped in the excessive space and create dimples on the corneal surface. Antibiotics will not affect dimple veil staining, nor will lenticulating the edges. Re-evaluating the lens to cornea relationship will identify the problem and allow the fitter to change the base curve and/ or peripheral curves to eliminate the dimples.
🤔Hit Me UP__ Inbox Open 24/7 – 365 …...!!!! 🤔 Chat with us here : 🤔 Hybridgrades101@gmail.com
- =Answer>> Fleischer's Ring, (iron deposits at the
base of a cone) - =Answer>> comeal scarring due to rigid lens wear Need Writing 🤔Help? We've Got You Covered! ✍ 100% NO A I or Plagiarism Guaranteed🤔
🤔Hit Me UP__ Inbox Open 24/7 – 365 …...!!!! 🤔 Chat with us here : 🤔 Hybridgrades101@gmail.com
🤔Hit Me UP__ Inbox Open 24/7 – 365 …...!!!! 🤔 Chat with us here : 🤔 Hybridgrades101@gmail.com C. photorefractive keratectomy. D. photorefractive keratoplasty. C. photorefractive keratectomy. Ch11-13. Which of the following affects the successful outcome of a PRK procedure? A. Hydration of the corneal tissue B. Centration of the ablation zone C. Energy density of the laser beam D. All of the above. D. All of the above. Ch11-14. The main difference between PRK and PRKa is the A. fluence of the laser. B. asymmetric ablation. C. fixation of the pupil. D. method of removing the epithelium. B. asymmetric ablation. Ch11-15. ALK stands for which of the following is not important to document in medical records for contact lens patients? - =Answer>> Need Writing 🤔Help? We've Got You Covered! ✍ 100% NO A I or Plagiarism Guaranteed🤔
🤔Hit Me UP__ Inbox Open 24/7 – 365 …...!!!! 🤔 Chat with us here : 🤔 Hybridgrades101@gmail.com location at which the patient was originally taught insertion and removal which of the following will not increase the movement of a tight fitting rigid gas permeable lens? - =Answer>> enlarge the posterior optic zone After building up her wearing time, Jennifer returned for an afternoon recheck after eight hours of lens wear. The lenses moved <0.5 mm and her complaints were minimal except for late afternoon burning. Which would you suspect? - =Answer>> tight lens To correct a flat fitting rigid gas permeable lens you should: - =Answer>> Enlarge the optical zone IN order to create a smooth blend between the intermediate and peripheral curve of the following contact, which radius tool should be used? CPC 7.50 mm (45.00 D) IPC 8.50 mm PPC 10.50 mm - =Answer>> 9. which of the following polishing compounds should not be used with gas permeable lenses - =Answer>> Silvo To increase tear exchange with a rigid gas permeable lens what should be attempted? - =Answer>> Reduce the overall lens diameter, Flatten the peripheral curves, and decrease the optic zone Advantages of a myoflange versus a single cut high plus lens include: 1.) Reduce center thickness Need Writing 🤔Help? We've Got You Covered! ✍ 100% NO A I or Plagiarism Guaranteed🤔
🤔Hit Me UP__ Inbox Open 24/7 – 365 …...!!!! 🤔 Chat with us here : 🤔 Hybridgrades101@gmail.com Rx -3.00 -1.00 x 170 Given the above Rx and K's, the following diagnostic toric soft lens was used: 8.8 -3.00 -1.00 x 180 During the diagnostic evalution, the above lens rotated 10 degrees clockwise. The lens ordered should have an axis of 180 degrees Once the correctly ordered lens has been dispensed, the rotational marks should settle at: - =Answer>> 10 degrees clockwise When there is slight pooling of fluorescein in the peripheral curve portion of a rigid lens, it indicates: - =Answer>> slight edge lift a rigid lens showing a band-shaped area of touch on the flattest meridian is an indication of: - =Answer>> An astigmatic fit a rigid lens showing central vaulting is indicative of: - =Answer>> Apical clearance fit contact lenses that have a non-spherical back surface are called: - =Answer>> Aspheric lenses A rigid lens showing excessive apical pooling is an indication of: - =Answer>> a steep fit A rigid lens showing apical touch is an indication of: - =Answer>> A flat fit Need Writing 🤔Help? We've Got You Covered! ✍ 100% NO A I or Plagiarism Guaranteed🤔
🤔Hit Me UP__ Inbox Open 24/7 – 365 …...!!!! 🤔 Chat with us here : 🤔 Hybridgrades101@gmail.com A patient with a high degree of a with-the-rule astigmatism fitted with a spherical rigid gas permeable lens will show touch: - =Answer>> on the horizontal meridian A soft contact lens that is too loose may show all of the following:? - =Answer>> edge stand off, excessive lens movement, distorted retinoscopy directly after blinking Among the following choices, which is the latest lens design for keratoconus? - =Answer>> Rose k design Which of the following could cause a patient's rigid contact lens to displace frequently and pop out without cause? 1.) Excessive posterior peripheral curve 2.) Insufficient peripheral curve 3.) Steep base curve relationship 4.) Flat base curve relationship - =Answer>> 1 and 4 excessive posterior peripheral curve and flat base curve relationship A normal fitting standard thickness soft contact lens will exhibit - =Answer>> three point touch (apex and periphery) When evaluating fluorescein patterns, a special filter must be used with: - =Answer>> Polymers with a UV blocker Causes of lens flexure may include: - =Answer>> Pressure exerted by the upper lid high dk lens material apical clearance lens design Need Writing 🤔Help? We've Got You Covered! ✍ 100% NO A I or Plagiarism Guaranteed🤔
🤔Hit Me UP__ Inbox Open 24/7 – 365 …...!!!! 🤔 Chat with us here : 🤔 Hybridgrades101@gmail.com A soft lens has edge lift when observed on cornea. How can this be corrected? - =Answer>> Steepen the base curve Corneal edema is observed inferiorly under a prism ballast toric soft lens what is the probable cause? - =Answer>> Prism thickness is too great Which type of slit lamp illumination will allow you to determine corneal thickening, thinning and distortion and depth of foreign bodies or opacities in the cornea? - =Answer>> Optic section Gross corneal edema, which manifests itself clinically as central corneal haze, is verified by the slit lamp using sclerotic scatter illumination. What specific technique does the examiner use to see this condition - =Answer>> the naked eye and an angle between the slit lamp beam and the eye of 90 degrees when inspecting the bend on the blend on bevel of an RGP lens: - =Answer>> An ideal blend should show a J- shaped or ski pattern in a smooth curve Diffuse central punctate staining is an indication of: - =Answer>> Tight lens Sandy returns to your office after being fit with soft contact lenses. She has complaints of the lenses becoming uncomfortable and burning as the day progresses. What might be the reason? - =Answer>> The lens is too tight Need Writing 🤔Help? We've Got You Covered! ✍ 100% NO A I or Plagiarism Guaranteed🤔
🤔Hit Me UP__ Inbox Open 24/7 – 365 …...!!!! 🤔 Chat with us here : 🤔 Hybridgrades101@gmail.com With a rigid contact lens in place, a fluorescein pattern shows a concentration of fluorescein inferiorly and superiorly beneath the lens. Which one of the following types of astigmatism is represented by this pattern? - =Answer>> With-the-rule astigmatism Mary is swearing rigid gas permeable lens with a base curve of 43.50 D and a power +2.75 D. She requires a - 0.75 D sphere over this lens. If you wish to order her a new lens a curve of 43.00 D, what will the new power be? - =Answer>> +2.50 D FDA Group 1 soft lenses - =Answer>> have a water content lower than 50% and a non-ionic surface Which of the following modifications to a rigid gas permeable lens can not be made in the office - =Answer>> changing the base curve In-office polishing of the anterior surface of rigid gas permeable lens surface of a rigid gas permeable lens surface will provide many benefits to the patient. Which of the following is not a benefit of polishing the lens in the office - =Answer>> Thinner lens edge What is the most important feature of an in-office modification unit? - =Answer>> variable speed motor If a patient with exophthalmic eyes due to thyroid disease requires a topic lens:
🤔Hit Me UP__ Inbox Open 24/7 – 365 …...!!!! 🤔 Chat with us here : 🤔 Hybridgrades101@gmail.com Use of Wratten #12 or Tiffen yellow filter is important in evaluating the fluorescein pattern of patients with RGP lenses because: - =Answer>> Many patients are wearing lenses containing UV inhibitors that block fluorescein If fluorescein evaluation reveals apical staining, it could be due to: - =Answer>> a lens that is too flat and loose, a lens that is too steep and tight, corneal edema Newly fitted extended wear patients should have their first recheck in: - =Answer>> 24 hours If an adapted contact lens wearer complaints of a sudden onset of discomfort, the technical should suspect: - =Answer>> a damaged contact lens If an RGP lens fails to provide acceptable visual acuity, the fitter should first: - =Answer>> have a sphero- cylindrical over-refraction performed to see if the reduced acuity is due to residual astigmatism According to the FDA, disposable contact lenses that are removed nightly, should be discarded after: - =Answer>> 2 weeks Three and nine o'clock staining in RGP lens wears can best be eliminated by: - =Answer>> Reducing center and edge thickness and teaching the patient to blink completely Circumcorneal injection in a soft lens wearer may be sign of: - =Answer>> Tight lens syndrome, solution sensitivity, keratitis Need Writing 🤔Help? We've Got You Covered! ✍ 100% NO A I or Plagiarism Guaranteed🤔
🤔Hit Me UP__ Inbox Open 24/7 – 365 …...!!!! 🤔 Chat with us here : 🤔 Hybridgrades101@gmail.com A technical can perform a preliminary evaluation of soft contact lens movement by: A. Observing the movement of the lens edge in relation to the position of a conjunctival vessel B. Having the patient look up and blink C. observing movement and lens lag in upward and lateral gaze with a penlight D. all of the above - =Answer>> D. all of the above The purpose of a combination wetting/soaking RGP solution is to: - =Answer>> maintain lens surface wettability, disinfect the lens, cushion the lens during insertion Enzymatic cleaning of soft lenses is important in: A. preventing the development of GPC B. Preventing the lens from shrinking and tightening C. Maintaining the hydration of the lens D. All of the above - =Answer>> D. All of the above Which of the following statements about eye make-up is correct? A. Eyeliner should be applied to the inner margin of the eyelids behind the layers B. Eyeliner and mascara should be replaced every 3 to 6 months to avoid contamination C. Mascara should be applied to the base of the lashes only D. Eye make-up should be applied before inserting contact lens - =Answer>> B. Eyeliner and mascara should be replaced every 3 to 6 months to avoid contamination Need Writing 🤔Help? We've Got You Covered! ✍ 100% NO A I or Plagiarism Guaranteed🤔