Docsity
Docsity

Prepare for your exams
Prepare for your exams

Study with the several resources on Docsity


Earn points to download
Earn points to download

Earn points by helping other students or get them with a premium plan


Guidelines and tips
Guidelines and tips

LIVE FIRE INSTRUCTOR TEST 2025 | ALL QUESTIONS AND CORRECT ANSWERS | VERIFIED ANSWERS, Exams of Safety and Fire Engineering

LIVE FIRE INSTRUCTOR TEST 2025 | ALL QUESTIONS AND CORRECT ANSWERS | VERIFIED ANSWERS | ALREADY GRADED A+ | NEWEST EXAM (JUST RELEASED)

Typology: Exams

2024/2025

Available from 03/25/2025

essay-writers
essay-writers 🇺🇸

3.8

(91)

1.9K documents

1 / 20

Toggle sidebar

This page cannot be seen from the preview

Don't miss anything!

bg1
LIVE FIRE INSTRUCTOR TEST 2025 | ALL QUESTIONS
AND CORRECT ANSWERS | VERIFIED ANSWERS |
ALREADY GRADED A+ | NEWEST EXAM (JUST
RELEASED)
The _________ shall provide for rest and rehab of members operating at
the scene; including any necessary medical evaluations and treatment;
food and fluid replenishment, and relief from climactic conditions ---------
CORRECT ANSWER-----------------Instructor in Charge
In non gas fired training center buildings the engineer shall core solid
structural concrete slabs and walls that have been exposed to
temperatures in excess of __________ to check for hidden delaminatins
and to test compressive strength ---------CORRECT ANSWER-----------------
300 degrees F.
All _______ shall be restricted to an area outside the operations area
perimeter established by the safety officer ---------CORRECT ANSWER------
-----------spectators
The evacuation signal must be: ---------CORRECT ANSWER-----------------
Demonstrated to all participants
Remote fuel shut offs on props that use pressure to move fuel should be
placed so that the operator is: ---------CORRECT ANSWER-----------------
within eye sight of the prop
pf3
pf4
pf5
pf8
pf9
pfa
pfd
pfe
pff
pf12
pf13
pf14

Partial preview of the text

Download LIVE FIRE INSTRUCTOR TEST 2025 | ALL QUESTIONS AND CORRECT ANSWERS | VERIFIED ANSWERS and more Exams Safety and Fire Engineering in PDF only on Docsity!

LIVE FIRE INSTRUCTOR TEST 2025 | ALL QUESTIONS

AND CORRECT ANSWERS | VERIFIED ANSWERS |

ALREADY GRADED A+ | NEWEST EXAM (JUST

RELEASED)

The _________ shall provide for rest and rehab of members operating at the scene; including any necessary medical evaluations and treatment; food and fluid replenishment, and relief from climactic conditions --------- CORRECT ANSWER-----------------Instructor in Charge In non gas fired training center buildings the engineer shall core solid structural concrete slabs and walls that have been exposed to temperatures in excess of __________ to check for hidden delaminatins and to test compressive strength ---------CORRECT ANSWER----------------- 300 degrees F. All _______ shall be restricted to an area outside the operations area perimeter established by the safety officer ---------CORRECT ANSWER------ -----------spectators The evacuation signal must be: ---------CORRECT ANSWER----------------- Demonstrated to all participants Remote fuel shut offs on props that use pressure to move fuel should be placed so that the operator is: ---------CORRECT ANSWER----------------- within eye sight of the prop

There are utility services adjacent to the live burn site that can not be removed you must. ---------CORRECT ANSWER-----------------protect the utility services The ________ provides the authorization to qualify the fire instructors used in live fire evolutions ---------CORRECT ANSWER-----------------AHJ (authority having jurisdiction) Fireground communications shall be established so: ---------CORRECT ANSWER-----------------External requests for assistance can be made The __________ of the live fire evolution shall determine, prior to each specific evolution, the number of training attack lines and backup lines that are necessary ---------CORRECT ANSWER-----------------Instructor in Charge All of the following shall be secured from the owner of the structure in order for the fire department to conduct live fire training evolutions within the aquired building except ---------CORRECT ANSWER-----------------birth certificate A fire department wants to use your computer controlled gas-fired burn prop, the following personnel should be available ---------CORRECT ANSWER-----------------qualified operator A_______ plan shall be prepared and utilized during the briefing sessions prior to ignition ---------CORRECT ANSWER-----------------Preburn

For Live fire evolutions in a gas fired faciltiy the pre burn briefing session shall cover ---------CORRECT ANSWER-----------------pre-burn plan including all features of the training area and structure you have determined that your live fire training could cause visibility hazard to motorists, you should: ---------CORRECT ANSWER-----------------eliminate that hazard utilizing warning signs or possibly blocking the street The fire shall be ignited by __________in the presence of and under the direct supervision of the ---------CORRECT ANSWER-----------------ignition officer; safety officer The structural integrity of the non-gas fired training building shall be evaluated and documented ________yrs by a licensed professional engineer with burn building experienece and expertise ---------CORRECT ANSWER-----------------5 years Structure acquired by the AHJ from a property owner for the purpose of conducting live fire training or rescue training evolutions is a(an) --------- CORRECT ANSWER-----------------Acquired Structure Debris found in or around the structure that could burn in unanticipated ways, react violently , or create environmental or health hazards, shall be. - --------CORRECT ANSWER-----------------removed or stored in a protected area

Additional ____________ shall be designated when factors such as extreme temperatures or large groups are present, and classes of long durations are planned ---------CORRECT ANSWER-----------------instructors When should extreme weather conditions be considered? --------- CORRECT ANSWER-----------------when there is a risk of injury or illness to the participants The definition according to NFPA 1403, for an act of showing a skill is: ------ ---CORRECT ANSWER-----------------demonstration When using exterior props:there should be sufficient space for --------- CORRECT ANSWER-----------------all attack and backup lines to operate freely Prior to exposing students to live flames in a gas fired facility, instructors should ---------CORRECT ANSWER-----------------run the system Which of the following is incorrect regarding the requirement to breathe from a SCBA air supply ---------CORRECT ANSWER-----------------When the atmosphere contains a 20.5% oxygen atmosphere When considering two seperate sources and using a public water supply system, two pumpers on ___________should be used ---------CORRECT ANSWER-----------------two different hydrants

delivery valves to prevent fuel from flowing without confirmed pilot flames presence A oxygen deficient atmosphere is what % of oxygen? ---------CORRECT ANSWER-----------------19. Structure designed for conducting live fire training on a repetitive bases is? ---------CORRECT ANSWER-----------------training center burn building An individual qualified as an instructor and designated by the AHJ to be in charge is considered what? - --------CORRECT ANSWER----------------- Instructor in charge The structure integrity of exterior props shall be inspected how often? ------- --CORRECT ANSWER-----------------Annually The safety of visitor/spectators is whose responsibility? ---------CORRECT ANSWER-----------------Safety officer An individual qualified by the AHJ to deliver firefighting training and supervise students is an? ---------CORRECT ANSWER----------------- Instructor Linoleum can contribute to unexpected fire intensity how? --------- CORRECT ANSWER-----------------It's been preheated by repeated fire exposures

Who may play the role of a victim in a live fire scenario? ---------CORRECT ANSWER-----------------No one Indivudual appointed by the AHJ as qualified to maintain a safe working environment is? ---------CORRECT ANSWER-----------------Safety officer Metal fires should have an adequate back up supply of how much extinguishing agent? ---------CORRECT ANSWER-----------------150% reserve NFPA 1403 identifies the minimum level of training required to participate in a live fire training as? ---------CORRECT ANSWER-----------------NFPA 1001, Firefighter 1 Adjacent properties that could be effected by smoke should be notified what? ---------CORRECT ANSWER-----------------The exact day and time of training If the evolution involves the failure of a safety feature of fuel, the failed part shall be located _________ from the properly functioning safety feature. ---- -----CORRECT ANSWER-----------------downstream When must students wear an SCBA?/ participants must be breathing from a SCBA when? ---------CORRECT ANSWER-----------------When the atmosphere is suspected of containing containments

The _____ has Authority regardless of rank to intervene and stop a training evolution. ---------CORRECT ANSWER-----------------Safety officer To combat flashover or backdraft scenarios you must? or to avoid uncontrolled flashover or backdraft you must: ---------CORRECT ANSWER- ----------------limit fuel load to provide realistic training students should be advised of what? --------- CORRECT ANSWER-----------------Possible victims in the structure; be advised that there may be possible victims How often should the burn building evaluation include the removal and reinstallation of representative area of thermal linings to inspect hidden conditions behind the linings ---------CORRECT ANSWER----------------- Every 5 years You acquired a structure and the stairs do not have stair treads, what must you do? ---------CORRECT ANSWER-----------------Repair or preplace treads A search of the structure for unauthorized people should be conducted before? ---------CORRECT ANSWER-----------------Ignition ________ are allowed within operation perimiters, and shall be escorted at all times. ---------CORRECT ANSWER-----------------visitors

Student is injured, when is a report needed? ---------CORRECT ANSWER-- ---------------Always fuel loading in a room being used for live fire training includes all except? -- -------CORRECT ANSWER-----------------removal of floor coverings Any peron present at a live fire evolution for training is a what? --------- CORRECT ANSWER-----------------Student Which safety devises should be check prior to the evolution? --------- CORRECT ANSWER-----------------All safety devises The ________ of the live fire evolution shall determine all specifics of the training evolution ---------CORRECT ANSWER-----------------Instructor in charge To confirm ownership of the acquired structure you must? --------- CORRECT ANSWER-----------------Contact your organizations legal counsel the fire shall be ignited by the _________ in the presence and supervision of __________. ---------CORRECT ANSWER-----------------Ignition officer, safety officer

water supple for attack lines and backup lines must come from where? ----- ----CORRECT ANSWER-----------------two separate sources When igniting the fuel load, what must the ignition office have? --------- CORRECT ANSWER-----------------charged hose line Fire control team Is how many people? ---------CORRECT ANSWER--------- --------2 minimum The Ignition officer is apart of what team? ---------CORRECT ANSWER------ -----------Fire control team Who lights the fire? ---------CORRECT ANSWER-----------------Ignition officer EMS with transport capabilities needs to be on scene when? --------- CORRECT ANSWER-----------------Acquired structure evolution Who determines water supply for training evolution? ---------CORRECT ANSWER-----------------Instructor in charge, safety officer NFPA 1403? ---------CORRECT ANSWER-----------------Standard on live fire training

NFPA 1981 ---------CORRECT ANSWER-----------------Standard on SCBA NFPA 1982 ---------CORRECT ANSWER-----------------Standard on PASS system NFPA 1041 ---------CORRECT ANSWER-----------------Standard for Fire Service Instructor NFPA 1500 ---------CORRECT ANSWER-----------------Standard on Fire Department Safety NFPA 1001 ---------CORRECT ANSWER-----------------Standard for Fire Fighter Professional Qualifications Fuel materials for live fire? ---------CORRECT ANSWER-----------------Wood products Can Flammable liquids be used to in live fire? ---------CORRECT ANSWER- ----------------No What flash point does liquid combustibles have to be above? --------- CORRECT ANSWER----------------- 100

Pre-burn briefing shall be conducted by ____________ with the __________. ---------CORRECT ANSWER-----------------Instructor in charge, safety officer Closed vessels that cannot be removed shall be _______ to prevent explosion? ---------CORRECT ANSWER-----------------vented Utilities should be what during live fire scenario? ---------CORRECT ANSWER-----------------disconnected How should flammable gas fires NOT be ignited? ---------CORRECT ANSWER-----------------manually At least once every ________ years GAS fired live fire training structure shall be evaluated and documented by a LICENSED PROFESSIONAL. ---- -----CORRECT ANSWER----------------- 10 Live fire training structures shall be evaluated by the AHJ or BUILDING OWNER how often? ---------CORRECT ANSWER-----------------Annually Calcium aluminate concrete shall be inspected every ______ years? --------

  • CORRECT ANSWER----------------- 3

You must remove and reinstall a area of thermal linings every ______ years in order to check? ---------CORRECT ANSWER-----------------10, hidden conditions behind the linings NON-GAS live fire training structures should be tested how when? --------- CORRECT ANSWER-----------------5 years NON-GAS live fire training structures thermal linings should be replaced and check how often? and for what? ---------CORRECT ANSWER------------- ----5 years, hidden conditions What should the AHJ create for multiple sequence burns? --------- CORRECT ANSWER-----------------A burn sequence matrix chart What is on a burn sequence matrix chart? ---------CORRECT ANSWER------ -----------1. Max fuel load per evolution

  1. maximum number of sequential evolutions Max fuel load and number of sequential evolutions shall not be _______ under any circumstances. ---------CORRECT ANSWER----------------- exceeded Exterior live fire props shall be inspected and documented how often? ------ ---CORRECT ANSWER-----------------annually

Which of the following is true regarding the availability of EMS? --------- CORRECT ANSWER-----------------They should be onsite A system that defines the roles and responsibilities to be assumed by personnel and the operating procedures to be used in the management and direction of emergency operations is called ---------CORRECT ANSWER-----------------Incident Management System When can a student function as the ignition officer ---------CORRECT ANSWER-----------------They can not function in this capacity at any time The Two desired environments for the conduct of a live fire program is ------ ---CORRECT ANSWER-----------------safe and controlled _______ fire at a time shall be permitted within the aquired structure --------- CORRECT ANSWER-----------------One (1) In relation to determining what constitutes valid separate sources and using tankers or folding tank, how many pumpers should be used to supply the attack and backup lines. ---------CORRECT ANSWER-----------------Two (2) After participants have entered the aquired structure, you light a fire in the doorway to simulate fire extension. This practice is? ---------CORRECT ANSWER-----------------not acceptable since it is blocking an exit

when using flammable or combustible liquids ---------CORRECT ANSWER-- ---------------runoff should be prevented from contaminating the surrounding area