Journeyman's Plumbing Exam: Comprehensive Guide to Standards & Practices, Exams of Engineering

A comprehensive overview of plumbing standards and practices, covering a wide range of topics, including backwater valves, sewage ejectors, macerating toilet systems, drainage connections, water heater installation, and sewer system requirements. It includes a series of questions and answers that can be used for studying and preparing for plumbing exams. Valuable for anyone seeking to learn about plumbing codes and regulations.

Typology: Exams

2024/2025

Available from 01/08/2025

Martin-Ray-1
Martin-Ray-1 🇺🇸

5

(8)

6.1K documents

1 / 36

Toggle sidebar

This page cannot be seen from the preview

Don't miss anything!

bg1
Journeyman's Plumbing Exam with
Answers A+ Graded.
20' - Answer: Underfloor clean-up shall not be located more than
_____ from an access door, trap door, or crawl hole
Back Water Valve - Answer: When plumbing fixtures are installed on
a floor level lower than the next upstream manhole cover of the
sewer, such drainage piping shall be protected from backflow of
sewage by a ____________
20 - Answer: Sewage ejectors receiving the discharge of water
closets or ruinals shall have a discharge capacity not less than ___
gallons per minute
2" - Answer: What is the minimum size discharge pipe for an ejector
installed in a single dwelling?
2" - Answer: The lowest inlet connected to the ejector pump shall
have a clearance of not less than ____ from the high water or
starting level of the sump.
Yes, with prior approval of the AHJ - Answer: Can macerating toilet
systems be installed instead of a sewage pump system
pf3
pf4
pf5
pf8
pf9
pfa
pfd
pfe
pff
pf12
pf13
pf14
pf15
pf16
pf17
pf18
pf19
pf1a
pf1b
pf1c
pf1d
pf1e
pf1f
pf20
pf21
pf22
pf23
pf24

Partial preview of the text

Download Journeyman's Plumbing Exam: Comprehensive Guide to Standards & Practices and more Exams Engineering in PDF only on Docsity!

Journeyman's Plumbing Exam with

Answers A+ Graded.

20' - Answer: Underfloor clean-up shall not be located more than _____ from an access door, trap door, or crawl hole

Back Water Valve - Answer: When plumbing fixtures are installed on a floor level lower than the next upstream manhole cover of the sewer, such drainage piping shall be protected from backflow of sewage by a ____________

20 - Answer: Sewage ejectors receiving the discharge of water closets or ruinals shall have a discharge capacity not less than ___ gallons per minute

2" - Answer: What is the minimum size discharge pipe for an ejector installed in a single dwelling?

2" - Answer: The lowest inlet connected to the ejector pump shall have a clearance of not less than ____ from the high water or starting level of the sump.

Yes, with prior approval of the AHJ - Answer: Can macerating toilet systems be installed instead of a sewage pump system

3/4" - Answer: What is the minimum size discharge pipe for a macerating toilet system

1/4" per foot - Answer: What is the minimum pitch required fora 2" horizontal drain?

Swing check valve - Answer: The discharge line from an ejector pump shall be provided with an accessible ___________ and gate or ball valve.

Downstream of the backwater valve - Answer: Where shall the gate valve be located on the discharge line on an ejector pump

8' - Answer: Drainage connections shall not be made into a drainage piping system within ________ of an vertical or horizontal change in direction of a stack containing suds producing fixtures.

10' Head of water for 15 minutes

5 psi for and air test - Answer: What are the requirements when testing the DWV system Water and Air?

When the dwelling is more than 200' away from the sewer. -

Answer: When is the public sewer considered not being available?

2' away from the building - Answer: At what point does the building sewer begin?

Owner or owners agent - Answer: Who is responsible for maintaining the plumbing and drainage system in a building?

Work or systems that have already been installed prior to the

effective date of the existing code. - Answer: What is meant by the term "existing work"?

Blockages or leaks - Answer: What type of work is exempt from a plumbing permit?

180 Days - Answer: If work is not started, how many days is a permit valid?

After it has been tested, inspected, and approved - Answer: When can plumbing work be covered and concealed?

Person with the permit, doing the work - Answer: Who notifies the authority have jurisdiction when plumbing work is ready for inspections?

Prevent siphonage - Answer: What is the purpose of a vacuum relief valve

To slow corrosion of the inside of the tank - Answer: What is the purpose of the anode rod?

To send cold water to the bottom of the tank - Answer: What is the purpose of the dip tube?

To prevent siphonage and back pressure on the dip tube. - Answer: What is the purpose of the anti-siphon hole?

When the water temperature drops below a set temperature the

immersion element turns on to reheat the water. - Answer: Explain how the electric immersion elements work on an electric water heater.

Ohms on a multimeter to check for continuity - Answer: How does a plumber check to see if an immersion element is good or bad

6" above the water heater on the cold water supply - Answer: Where shall the vacuum relief valve be located

fullway valve - Answer: What type of valve is required on the cold water supply to a water heater

18" - Answer: Pex tubing shall not be installed within the first ______ of the pitting connected to a water heater

24" - Answer: What is the maximum length flexible water heater connector allowed

210° - Answer: At what °F will the temperature and pressure valve relieve?

Iron Pipe Size - Answer: What does IPS stand for?

In any building in which plumbing fixtures are installed - Answer: When is a sewer required?

Ashes, Cinder, solids, rags, inflammable, poisonous or explosive

liquids, oils, grease - Answer: Name five materials that are prohibited from entering the drainage system or public sewer.

No - Answer: Can rainwater be discharged into the sanitary drainage system?

They must be moved or relocated to the proper location - Answer: What does the UPC 2009 code say in regard to the improper location of piping, fixtures, or equipment.

No, the section of pipe must be replaced - Answer: Can a plumber use plumbers epoxy to repair a crack in a cast iron soil stack?

They must be reamed - Answer: What shall be done to burred ends of pipe?

Double hub fittings

Single Tee Branch

Double Tee Branch

side inlet quarter bend

running thread bend

saddles - Answer: Name 4 prohibited fittings.

No - Answer: Can a plumber thread cast iron soil pipe?

No - Answer: Can a 2" vent stack be embedded in masonry wall?

12" - Answer: What is the minimum depth below the surface of the ground for a drainage pipe within a building?

No - Answer: Can a vent pipe be installed in an outside wall?

No - Answer: Can water pipes be installed in an outside wall?

With Flashing - Answer: How are vent pipes passing through the roof of a building be made water tight?

18 gauge nail guards must be installed on stud. - Answer: What has to be done with plastic and copper piping within 1" of exposed framing?

Gauge must be for the increment of 1/10 - Answer: A copper DWV system is to be tested with air to a pressure of 5 psi what are the requirements for the gauge to be used for this test?

4' - Answer: What is the maximum horizontal hangar spacing for sch. 40 PVC drainage system?

10' - Answer: What is the maximum horizontal hangar spacing for copper tubing?

-1/2"-1 1/2"

-2+"

32" - Answer: What is the maximum horizontal hanger pacing for pex tubing?

Closet bend flange - Answer: Floor mounted water closets shall be connected to the drainage systems by the means of an approved ____________.

80 - Answer: Threaded plastic pipe shall be schedule ________ minimum wall thickness

1st 3 male - Answer: When pipe joint material is used it shall be applied only on the ______________ threads

1 - Answer: How many traps are permitted on a trap arm?

1 - Answer: How many traps are required far a set of three lavatories that are within the maximum allowable code distance?

30" - Answer: What is the maximum distance that the waste outlets in question 2 can be apart?

Centrally under the middle sink. - Answer: Where shall the trap or traps be located on question 2?

24" - Answer: What is the maximum length for a tailpiece?

A fitting or device so designed and constructed as to provide, when properly vented, a liquid seal that will prevent the back passage of air without materially affecting the flow of sewage or wastewater

through it. - Answer: Define Trap

When the trap is within 2 pipe diameters of the vent stack which in

turn could cause quicker trap evaporation or blockages. - Answer: What does crown venting mean?

90° - Answer: A trap arm can change direction without the use of a cleat provided the change of direction does not exceed _________.

1 - Answer: How many pipe sizes can a trap arm and trap be increased?

S Trap, Bag Trap, J Trap, Bottle Trap, Crown vented trap - Answer: Name 3 prohibited traps.

What are the minimum and maximum trap liquid seal depths -

Answer: 2"-4"

Back Water Valve - Answer: Floor drains subject to reverse flow of sewage or liquid waste shall be equipped with an approved ____________.

When a trap is at risk of losing its seal doe to SAMOBECLP - Answer: When are trap primers required?

Must be vented to prevent back pressure on the inlet side, and must

have a readily accessible cleanout. - Answer: The AHJ has approved the plumber to install building trap. What are the two requirements to be met when installing the building trap?

6" - Answer: Interceptors for sand are required to have a water seal not less than ____________.

When a fixture is draining grease or some other substance that is

hazardous to the sanitary sewer. - Answer: When are grease interceptors required?

individually trapped and vented - Answer: Each fixture discharging into a grease interceptor shall be _______________ and ________________?

food particles will cause blockages in the line - Answer: Why is it not legal for a food waste disposal system to discharge into a grease interceptor?

Flotation, Sedimentation, Neutralization - Answer: What are the three methods for intercepting and treating wastes?

Vented flow control - Answer: Plumbing fixtures or equipment must discharge through an approved type of ___________ before connecting to a hydromechanical grease interceptor.

125 - Answer: A hydromechanical grease interceptor is rated for 50 gallons per minute. What is the total capacity in gallons of fixtures discharging into the interceptor allowed by code?

2 1/2 - Answer: The total capacity in gallons of fixtures discharging into a hydromechanical interceptor shall not exceed ___________ times the certified gym flow rate of the interceptor.

No it must be connected upstream of the disposal - Answer: Is it legal to connect the drain from a dishwasher on the discharge side of a food waste disposal unit?

Yes with the approval of the AHJ - Answer: Can a chemical toilet be installed in a building?

Caulk to create a watertight seal - Answer: When a fixture comes in contact with a wall or floor what must a plumber do?

Brass or a non corrosive material - Answer: What material would meet UPC 2009 requirement for screws or bolts when securing floor mounted fixtures

15" - Answer: What is the minimum side clearance allowed by code from the center of a bidet to a side wall?

30" - Answer: What is the minimum center-to-center distance required by code for a water closet set side-by-side?

24" - Answer: What is the minimum clear space required by code in front of a water closet?

24" - Answer: What are the minimum clearances required by code for a urinal?

from side wall to center? _____ from center-to-center of two urinals set side-by-side?__

elongated bowls - Answer: Water closets for public use shall be of the ___________ type.

open front - Answer: Water closet seats for public use shall be of the _________ type.

Name four allowable materials for closet flanges - Answer: DWV Brass, DWV Copper, DWV PVC, Cast Iron

2" minimum depth - Answer: What is the minimum depth for a caulked-on closet flange?

Vacuum Breaker - Answer: The water supply to a urinal shall be protected by an approved-type _______________ ______________.

1 - Answer: Manually operated flushometers shall be used to control not more than _____ urinal(s).

Toilet rooms, laundry rooms, commercial kitchen - Answer: Name 3 locations floor drains are required by code.

Bidet - 110° - Answer: What is the maximum temperature in F° for hot water to be delivered to:

public lavatory:

bathtub:

shower:

bidet:

1024 square inches - Answer: Shower compartments regardless of shape, shall have a minimum finished interior of _____________.

Lav, WC, Bath/shower, Kitchen sink, Laundry hookup - Answer: List the minimum fixtures required by code for a single family dwelling.

2' - Answer: The non-absorbent wall and floor materials surrounding a urinal shall extend

_______ in front of urinal lip;

_______ above the floor;

_______ to each side of the urinal.

No - Answer: Are trough urinals approved to be installed per UPC 2009?

1" of water column - Answer: The vent system seal be designed to prevent trap seal from being exposed to a pressure differential that exceeds.

Intercepter acts as a primary settling tank and discharges through a

secondary interceptor that is properly trapped and vented - Answer: When can vent piping be omitted on an interceptor?

No, as long as said sinks discharge indirectly into a floor skin or

approved receptor - Answer: Are vents required for traps serving sinks that are part of equipment of bars, soda fountains, and counters?

Sch 40 PVC, Sch 40 ABS, Copper, no hub - Answer: Name four allowable materials for vent piping above ground.

Yellow - Answer: What color marking is used to identify type DWV copper tubing

1 1/4" - Answer: What is the minimum individual vent size allowed by code?

4 - 2" Vent Pipes - Answer: A building requires a 4" building sewer; the plumber wants to use 2" vent pipes though the buildings roof. How many 2" vent pipes are required to meet code?