Study with the several resources on Docsity
Earn points by helping other students or get them with a premium plan
Prepare for your exams
Study with the several resources on Docsity
Earn points to download
Earn points by helping other students or get them with a premium plan
Community
Ask the community for help and clear up your study doubts
Discover the best universities in your country according to Docsity users
Free resources
Download our free guides on studying techniques, anxiety management strategies, and thesis advice from Docsity tutors
HVACR gas heating esco Questions & 100% Verified Answers | Latest Update | Already Graded A+
Typology: Exams
1 / 11
This page cannot be seen from the preview
Don't miss anything!
using an ohmmeter, there is 120 VAC between high speed and ground wires, this indicates ๐ธ๐ธ๐ธ : open if temperature rise is too high... ๐ธ๐ธ๐ธ : increase fan speed how many of the 3 OSHA conditions defining confined spaces must be met ๐ธ๐ธ๐ธ : all 3 what causes the temperature limit safety switch to shut off the burner ๐ธ๐ธ๐ธ : fan motor failure flashback indicates ๐ธ๐ธ๐ธ : the gas is flowing slower than the speed at which burn is occurring what type of connector is used to control noise in ductwork
๐ธ๐ธ๐ธ : vibration eliminators if the main burner lights and after a minute the blower fan comes on but the burner flames waver in one corner... ๐ธ๐ธ๐ธ : there is faulty blower housing a burner orifice... ๐ธ๐ธ๐ธ : meters gas to the burner when lockout/tagout is used ๐ธ๐ธ๐ธ : there should be 1 key kept by the electrician the gas pressure is usually ๐ธ๐ธ๐ธ : 3. a spark igniter operates at ๐ธ๐ธ๐ธ : 7,500 vac a good thermocouple produces ๐ธ๐ธ๐ธ : 30 millivolts what must be present for combustion
to change cubic feet per minute delivered to a single speed belt driven blower, you should adjust ๐ธ๐ธ๐ธ : the motor pulley size nitrogen combines with oxygen to form... ๐ธ๐ธ๐ธ : NOX when the burners are ignited, the blower is delayed to... ๐ธ๐ธ๐ธ : allow the heat exchanger to warm up gas piping must be installed with a pitch of ๐ธ๐ธ๐ธ : 1/4 inch per 15 ft pipe joint compound should be applied to ๐ธ๐ธ๐ธ : the male threads, not last 2 threads if voltage is applied across 2 speed terminals on a fan motor at the same time, the motor ๐ธ๐ธ๐ธ : runs too fast what is the result of an oversized mid efficiency furnace
๐ธ๐ธ๐ธ : the heat exchanger corrodes what draft moves flue gas through the heat exchange ๐ธ๐ธ๐ธ : mechanical furnace designed with the blower motor under the heat exchange is the ๐ธ๐ธ๐ธ : upflow a gas furnace is installed in a garage, the burners are ๐ธ๐ธ๐ธ : 18 inches above floor a carryover on a gas burner.. ๐ธ๐ธ๐ธ : provides smooth lighting of all burners 100% shutoff means ๐ธ๐ธ๐ธ : gas to the pilot and manifold are shut off a limit switch deenergizes the ๐ธ๐ธ๐ธ : gas valve if it overheats what checks the pressure of a furnace ๐ธ๐ธ๐ธ : manometer
the volts of a hot surface igniter is ๐ธ๐ธ๐ธ : 120 volts thermostats contain 1+ sets of contacts to control heating, they are ๐ธ๐ธ๐ธ : thermally actuated adjustable shutters ๐ธ๐ธ๐ธ : mix primary and gas 60000 btu/h operating at 50% air ๐ธ๐ธ๐ธ : 600 cu ft vent stack temp on a natural draft furnace is ๐ธ๐ธ๐ธ : 350 - 450 f 1/2 and 3/4 black pipe is installed, cut how many threads ๐ธ๐ธ๐ธ : 10 - 12 a furnace with the blower motor above the heat exchanger is a ๐ธ๐ธ๐ธ : downflow ASHRAE specify how much CO
๐ธ๐ธ๐ธ : 9 ppm air mixed with natural gas is ๐ธ๐ธ๐ธ : primary air severity of shock is determined by ๐ธ๐ธ๐ธ : intensity of flow and path external static pressure is ๐ธ๐ธ๐ธ :. 2 -. 6 in WC condensing furnaces work at ๐ธ๐ธ๐ธ : 90% LP has a gravity og ๐ธ๐ธ๐ธ : 1.5-2. pressure drop in natural gas piping is due to ๐ธ๐ธ๐ธ : friction or resistance a cat 4 2 pipe vent system thru roof has an elbow that ๐ธ๐ธ๐ธ : points down
the pilot assembly orifice is clogged ๐ธ๐ธ๐ธ : replace natural gas consists of ๐ธ๐ธ๐ธ : methane gas burners change diameter, referred to as ๐ธ๐ธ๐ธ : ventiru defective heat exchanger ๐ธ๐ธ๐ธ : inform homeowner and turn off supply of gas to furnace LP gases are ๐ธ๐ธ๐ธ : propane, butane flue baffle ๐ธ๐ธ๐ธ : increases heat exchange ignition temp of natural gas ๐ธ๐ธ๐ธ : 1100 - 1200
to test flame rectification ๐ธ๐ธ๐ธ : placemeters in series with flame sensor to test DC microamps 0 ohms b/w common and low speed wirings, winding is ๐ธ๐ธ๐ธ : shorted igniter in a hot surface ignition furnace doesnt energize ๐ธ๐ธ๐ธ : check for voltage thru pressure switch if a furnace makes a loud bang upon ignition ๐ธ๐ธ๐ธ : check supply to gas pressure testing resistance of a hot surface igniter ๐ธ๐ธ๐ธ : allow igniter to cool constant airflow, torque, and speed are types of ๐ธ๐ธ๐ธ : ECM motors