Docsity
Docsity

Prepare for your exams
Prepare for your exams

Study with the several resources on Docsity


Earn points to download
Earn points to download

Earn points by helping other students or get them with a premium plan


Guidelines and tips
Guidelines and tips

Heat Pump ESCO Questions and Answers: A Comprehensive Guide for HVAC Technicians, Exams of Refrigeration and Air Conditioning

A comprehensive set of questions and answers related to heat pump esco (energy savings contract) systems. It covers various aspects of heat pump operation, maintenance, and troubleshooting, including defrost cycles, balance points, and system efficiency. Designed to help hvac technicians understand the intricacies of heat pump technology and prepare for real-world scenarios.

Typology: Exams

2024/2025

Available from 02/23/2025

tizian-kylan
tizian-kylan ๐Ÿ‡บ๐Ÿ‡ธ

2.7

(21)

3.8K documents

1 / 17

Toggle sidebar

This page cannot be seen from the preview

Don't miss anything!

bg1
1 | P a g e
Heat Pump ESCO Questions & 100% Verified
Answers | Latest Update | Already Graded A+
An air-to-air heat pump has many of the same components as an air conditioning
system. The major difference is that a heat pump also has an
๐Ÿ—ธ๐Ÿ—ธ๐Ÿ—ธ: Reversing valve
What is the difference between "demand defrost" and "timed defrost"?
๐Ÿ—ธ๐Ÿ—ธ๐Ÿ—ธ: Demand defrost happens only when needed and timed defrost is based on
time/temperature.
The thermostat that controls the auxiliary electric heat according to the outdoor
temperature is called the;
๐Ÿ—ธ๐Ÿ—ธ๐Ÿ—ธ: Outdoor ambient thermostat
The outdoor temperature at which the heat pump provides the same amount of heat as
the heat loss of the conditioned space without an auxiliary heat is known as the;
๐Ÿ—ธ๐Ÿ—ธ๐Ÿ—ธ: Initial balance point
At what temperature is an outdoor ambient thermostat normally set?
๐Ÿ—ธ๐Ÿ—ธ๐Ÿ—ธ: Slightly above the initial balance point.
pf3
pf4
pf5
pf8
pf9
pfa
pfd
pfe
pff

Partial preview of the text

Download Heat Pump ESCO Questions and Answers: A Comprehensive Guide for HVAC Technicians and more Exams Refrigeration and Air Conditioning in PDF only on Docsity!

Heat Pump ESCO Questions & 100% Verified

Answers | Latest Update | Already Graded A+

An air-to-air heat pump has many of the same components as an air conditioning system. The major difference is that a heat pump also has an ๐Ÿ—ธ๐Ÿ—ธ๐Ÿ—ธ : Reversing valve What is the difference between "demand defrost" and "timed defrost"? ๐Ÿ—ธ๐Ÿ—ธ๐Ÿ—ธ : Demand defrost happens only when needed and timed defrost is based on time/temperature. The thermostat that controls the auxiliary electric heat according to the outdoor temperature is called the; ๐Ÿ—ธ๐Ÿ—ธ๐Ÿ—ธ : Outdoor ambient thermostat The outdoor temperature at which the heat pump provides the same amount of heat as the heat loss of the conditioned space without an auxiliary heat is known as the; ๐Ÿ—ธ๐Ÿ—ธ๐Ÿ—ธ : Initial balance point At what temperature is an outdoor ambient thermostat normally set? ๐Ÿ—ธ๐Ÿ—ธ๐Ÿ—ธ : Slightly above the initial balance point.

The outdoor coil is frozen solid on a "no heat" service call. The most likely reason is; ๐Ÿ—ธ๐Ÿ—ธ๐Ÿ—ธ : The outdoor fan is inoperative. In order to determine a heat pumps' balance point, you must first calculate; ๐Ÿ—ธ๐Ÿ—ธ๐Ÿ—ธ : The building's heat load. When a heat pump is used for heating and cooling, the system is sized by the; ๐Ÿ—ธ๐Ÿ—ธ๐Ÿ—ธ : Cooling load. A high efficiency heat pump system designed to function from high to low ambient conditions below 10*F, may have? ๐Ÿ—ธ๐Ÿ—ธ๐Ÿ—ธ : Two outdoor coils with each one incorporating a dual stage compressor. Room thermostats for heat pumps should be installed; ๐Ÿ—ธ๐Ÿ—ธ๐Ÿ—ธ : As near to the main return air grill as possible. When the heat pump compressor has malfunctioned, the customer has the option to switch the system into; ๐Ÿ—ธ๐Ÿ—ธ๐Ÿ—ธ : Emergency heat mode. Start up with a night set back digital thermostat requires the technician to always;

๐Ÿ—ธ๐Ÿ—ธ๐Ÿ—ธ : The system will not properly remove the humidity from the conditioned space. The most preferred method of charging any system in the field is; ๐Ÿ—ธ๐Ÿ—ธ๐Ÿ—ธ : By weight. What is the industry standard for deep vacuum? ๐Ÿ—ธ๐Ÿ—ธ๐Ÿ—ธ : Maintain 500 microns for 15 minutes. Good service practice for installation of a reversing valve includes; ๐Ÿ—ธ๐Ÿ—ธ๐Ÿ—ธ : Use heat paste and wet rags while brazing in the new valve. Off-cycle crankcase heat is provide by; ๐Ÿ—ธ๐Ÿ—ธ๐Ÿ—ธ : A small amount of current is passed through the start capacitor to start the heat winding. You are checking for proper airflow in CFM on a three ton heat pump system. The system has one return grill measuring 24"X24", which has a net free area of 3.4 square feet. You measure air velocity and calculate an average of 400 FPM. From this information you can conclude that; ๐Ÿ—ธ๐Ÿ—ธ๐Ÿ—ธ : Airflow in CFM is below normal range. What control operates the 1st stage of secondary heat?

๐Ÿ—ธ๐Ÿ—ธ๐Ÿ—ธ : The second heating stage of the indoor thermostat. What is the industry standard for maximum duration for defrost? ๐Ÿ—ธ๐Ÿ—ธ๐Ÿ—ธ : A maximum of 10 minutes. What is the recommended CFM across the evaporator cool of a heat pump? ๐Ÿ—ธ๐Ÿ—ธ๐Ÿ—ธ : 400 to 450 CFM If manufacturer specifications are not available, a good way to calculate cubic feet per minute through a coil is to; ๐Ÿ—ธ๐Ÿ—ธ๐Ÿ—ธ : Use temperature rise on emergency heat mode. What type of defrost is employed on this heat pump? ๐Ÿ—ธ๐Ÿ—ธ๐Ÿ—ธ : Time or temperature initiation, time and temperature termination. Which component is responsible for energizing auxiliary heat during the defrost cycle? ๐Ÿ—ธ๐Ÿ—ธ๐Ÿ—ธ : The defrost relay. When this unit switches to the heat mode, select the sequence of events which will take place. ๐Ÿ—ธ๐Ÿ—ธ๐Ÿ—ธ : The RVR coil is energized through TH-1. The CR coil is energized through the RVR contacts.

An R410A heat pump operating in the heating mode has a suction pressure 50 PSIG and head pressure of 285 PSIG has a compression ratio of; ๐Ÿ—ธ๐Ÿ—ธ๐Ÿ—ธ : 4.6: Which type of heat pump does not require a defrost cycle? ๐Ÿ—ธ๐Ÿ—ธ๐Ÿ—ธ : Water source. An R-410A heat pump operating in the cooling mode has a suction pressure of 131 PSIG. Adding 2 PSIG for pressure drop in the coil, the true outlet pressure is 131 PSIG. The temperature of the suction line at the outlet of the evaporator is 57ยฐ F. What is the superheat? ๐Ÿ—ธ๐Ÿ—ธ๐Ÿ—ธ : 12 Degrees On a time initiation/temperature termination defrost, the defrost time clock has one N.O. And N.C. switch. When do the positions of these switches change? ๐Ÿ—ธ๐Ÿ—ธ๐Ÿ—ธ : Every 30 or 90 minutes, depending on the cam installed in the timer. What would be the result of closing registers in rooms that are uninhabited while operating in the heating mode? ๐Ÿ—ธ๐Ÿ—ธ๐Ÿ—ธ : The discharge pressure and temperature will rise decreasing the life span of the unit.

What is the most common complaint from a customer changing from gas heat to a heat pump? ๐Ÿ—ธ๐Ÿ—ธ๐Ÿ—ธ : Cold air at high velocities coming out of the registers. When a heat pump is operating in the heat mode, the suction line at the compressor; ๐Ÿ—ธ๐Ÿ—ธ๐Ÿ—ธ : Cold and sweaty The use of a scroll type compressor on a heat pump can eliminate the need for a; ๐Ÿ—ธ๐Ÿ—ธ๐Ÿ—ธ : Suction line accumulator. A heat pump operates satisfactorily in the cooling mode, but not in the heat mode. This could be caused by; ๐Ÿ—ธ๐Ÿ—ธ๐Ÿ—ธ : A stuck check valve or clogged TXV screen. It is not always a good idea to immediately connect a standard gauge manifold set and hoses to a heat pump when a problem is suspected because; ๐Ÿ—ธ๐Ÿ—ธ๐Ÿ—ธ : The charge is critical, sometimes to 1/2 oz. refrigerant. Which component is responsible for changing the direction of the flow of refrigerant? ๐Ÿ—ธ๐Ÿ—ธ๐Ÿ—ธ : Reversing valve. Some heat pump systems use a ______________ as a metering device.

Because of the possibility of liquid flood-back, a heat pump that uses a reciprocating compressor should be equipped with a; ๐Ÿ—ธ๐Ÿ—ธ๐Ÿ—ธ : Suction Accumulator. A scroll type compressor; ๐Ÿ—ธ๐Ÿ—ธ๐Ÿ—ธ : is less susceptible to damage from liquid flood-back. On a split system heat pump. A "no heat/no cooling" service call, you turn the thermostat to the fan on/ cont position and the indoor fan operates. This action verifies that; ๐Ÿ—ธ๐Ÿ—ธ๐Ÿ—ธ : The transformer is functioning. On most air-to-air heat pumps; ๐Ÿ—ธ๐Ÿ—ธ๐Ÿ—ธ : The indoor and outdoor coils are the same size and physical capacity. A heat pump system, operating at 45ยฐF ambient, may be _______ efficient than electric resistance heat ๐Ÿ—ธ๐Ÿ—ธ๐Ÿ—ธ : 3 to 4 times more. Since electric resistance heat produces 1 watt of usable heat for each watt of energy purchased, electric resistance heat has a COP of; ๐Ÿ—ธ๐Ÿ—ธ๐Ÿ—ธ : 1:

As outdoor ambient air temperature decreases, a heat pump's COP; ๐Ÿ—ธ๐Ÿ—ธ๐Ÿ—ธ : Decreases. During the defrost cycle, the system switches to the ___________ Mode. ๐Ÿ—ธ๐Ÿ—ธ๐Ÿ—ธ : Cooling. During the heating mode, the refrigerant in the indoor coil is under; ๐Ÿ—ธ๐Ÿ—ธ๐Ÿ—ธ : High pressure. What three things happen in most air-to-air heat pump during defrost? ๐Ÿ—ธ๐Ÿ—ธ๐Ÿ—ธ : The reversing valve must switch to cooling mode, the outdoor fan shuts off and auxiliary heat is energized. High suction pressure and low discharge pressure on a heat pump system operating in either the heating or cooling mode can be an indication of; ๐Ÿ—ธ๐Ÿ—ธ๐Ÿ—ธ : Compressor inefficiency. The preferred method to preform adjustments to the refirgerant charge in a heat pump system is in the ________ more. ๐Ÿ—ธ๐Ÿ—ธ๐Ÿ—ธ : Cooling. You answer a service call for insufficient heat. You find the suction pressure is higher and discharge pressure is lower than normal. Using a digital thermometer, you measure

๐Ÿ—ธ๐Ÿ—ธ๐Ÿ—ธ : Time and temperature. The defrost cycle can be terminated by; ๐Ÿ—ธ๐Ÿ—ธ๐Ÿ—ธ : Time/temperature Movement of the piston in the reversing valve is accomplished by; ๐Ÿ—ธ๐Ÿ—ธ๐Ÿ—ธ : Bleeding pressure from one side of the piston to the suction side of the compressor. Some close coupled (package unit) heat pumps use an electronic expansion valve is; ๐Ÿ—ธ๐Ÿ—ธ๐Ÿ—ธ : Electronic expansion valves can meter refrigerant in either direction. Liquid line filter-driers that are used on heat pump system; ๐Ÿ—ธ๐Ÿ—ธ๐Ÿ—ธ : Must be a bi-flow design if used without check valves. When installing the heat pump outdoor unit, care should be taken to provide for drainage during the ________ cycle. ๐Ÿ—ธ๐Ÿ—ธ๐Ÿ—ธ : Defrost. The indoor coil is usually mounted in the air stream _______ the auxiliary electric heat strips. ๐Ÿ—ธ๐Ÿ—ธ๐Ÿ—ธ : Before.

On Dual Fuel Systems, the indoor coil must be located; ๐Ÿ—ธ๐Ÿ—ธ๐Ÿ—ธ : After the heat exchanger. Air-to-air heat pumps are most practical to operate in areas where the lowest winter temperature does not go below ______ *F ๐Ÿ—ธ๐Ÿ—ธ๐Ÿ—ธ : + 10 Air-to-air heat pumps, operating without auxiliary heat, provide air to the registers that is approximately _______ *F or less. ๐Ÿ—ธ๐Ÿ—ธ๐Ÿ—ธ : 100 The most common method of defrosting the outdoor coil on an air source heat pump is; ๐Ÿ—ธ๐Ÿ—ธ๐Ÿ—ธ : Reverse cycle defrost. COP is the abbreviation for; ๐Ÿ—ธ๐Ÿ—ธ๐Ÿ—ธ : Coefficient of performance. At temperatures above 45 degrees *F, the heat pump refrigeration cycle permits the; ๐Ÿ—ธ๐Ÿ—ธ๐Ÿ—ธ : Condenser to release 3 to 4 times more heat than it takes in electrical energy to drive the compressor.

A heat pump has a thermostatic expansion valve (TEV) and a check valve at each coil. When the modes are reversed; ๐Ÿ—ธ๐Ÿ—ธ๐Ÿ—ธ : Refrigerant will bypass the TEV on the coil serving as the condenser. Mechanically troubleshooting a reversing valve can be done by; ๐Ÿ—ธ๐Ÿ—ธ๐Ÿ—ธ : By checking the temperature differential between the connection serving the low side. Compressors designed for heat pumps differ from compressors designed for A/C in that; ๐Ÿ—ธ๐Ÿ—ธ๐Ÿ—ธ : It is designed to operate at high compression ratios. One of the most important devices to insure the longevity of a heat pump's reciprocating compressor is the; ๐Ÿ—ธ๐Ÿ—ธ๐Ÿ—ธ : Crankcase heater. A heat pump can be difficult to charge properly because; ๐Ÿ—ธ๐Ÿ—ธ๐Ÿ—ธ : Heat pumps can only be charged in the cooling mode. High efficient heat pump systems charged with R-410A refrigerant normally use a; ๐Ÿ—ธ๐Ÿ—ธ๐Ÿ—ธ : Fixed orifice metering device for the heating cycle and a TXV for the cooling cycle.

When a heat pump is operating in the cooling mode, the; ๐Ÿ—ธ๐Ÿ—ธ๐Ÿ—ธ : Indoor metering device is metering refrigerant and the outdoor check valve is open. When in the cooling mode, the low pressure refrigerant vapor leaves the reversing valve and tracked to the; ๐Ÿ—ธ๐Ÿ—ธ๐Ÿ—ธ : Accumulator and then to the compressor.