Docsity
Docsity

Prepare for your exams
Prepare for your exams

Study with the several resources on Docsity


Earn points to download
Earn points to download

Earn points by helping other students or get them with a premium plan


Guidelines and tips
Guidelines and tips

FLORIDA TERMITE EXAM VERSION 1 AND 2 EXAM 2025 WITH ACTUAL CORRECT QUESTIONS AND VERIFIE, Exams of Nursing

FLORIDA TERMITE EXAM VERSION 1 AND 2 EXAM 2025 WITH ACTUAL CORRECT QUESTIONS AND VERIFIED DETAILED ANSWERS |FREQUENTLY TESTED QUESTIONS AND SOLUTIONS 2025/2026

Typology: Exams

2024/2025

Available from 06/29/2025

drkingori
drkingori šŸ‡ŗšŸ‡ø

30 documents

1 / 62

Toggle sidebar

This page cannot be seen from the preview

Don't miss anything!

bg1
FLORIDA TERMITE EXAM VERSION 1
AND 2 EXAM 2025 WITH ACTUAL
CORRECT QUESTIONS AND VERIFIED
DETAILED ANSWERS |FREQUENTLY
TESTED QUESTIONS AND SOLUTIONS
2025/2026
1. _______ or below should be used when
trenching and treating with liquid
termiticides?ANSWER25 psi
2. ________ and _______ are both non repellent
insecticides?ANSWERneonicotinoids,
phenylpyrazole
3. ________ is the active ingredient that is a
repellentANSWERCypermethrin
4. according to the industry Baseline practices
what is the minimum opening size through the
truss webbing in the Attic?ANSWER22" x 48"
5. according to the industry Baseline practices,
what is the minimum opening size for an attic
entrance?ANSWER20" x 20"
pf3
pf4
pf5
pf8
pf9
pfa
pfd
pfe
pff
pf12
pf13
pf14
pf15
pf16
pf17
pf18
pf19
pf1a
pf1b
pf1c
pf1d
pf1e
pf1f
pf20
pf21
pf22
pf23
pf24
pf25
pf26
pf27
pf28
pf29
pf2a
pf2b
pf2c
pf2d
pf2e
pf2f
pf30
pf31
pf32
pf33
pf34
pf35
pf36
pf37
pf38
pf39
pf3a
pf3b
pf3c
pf3d
pf3e

Partial preview of the text

Download FLORIDA TERMITE EXAM VERSION 1 AND 2 EXAM 2025 WITH ACTUAL CORRECT QUESTIONS AND VERIFIE and more Exams Nursing in PDF only on Docsity!

AND 2 EXAM 2025 WITH ACTUAL

CORRECT QUESTIONS AND VERIFIED

DETAILED ANSWERS |FREQUENTLY

TESTED QUESTIONS AND SOLUTIONS

  1. _______ or below should be used when trenching and treating with liquid termiticides?ANSWER25 psi
  2. ________ and _______ are both non repellent insecticides?ANSWERneonicotinoids, phenylpyrazole
  3. ________ is the active ingredient that is a repellentANSWERCypermethrin
  4. according to the industry Baseline practices what is the minimum opening size through the truss webbing in the Attic?ANSWER22" x 48"
  5. according to the industry Baseline practices, what is the minimum opening size for an attic entrance?ANSWER20" x 20"

AND 2 EXAM 2025 WITH ACTUAL

CORRECT QUESTIONS AND VERIFIED

DETAILED ANSWERS |FREQUENTLY

TESTED QUESTIONS AND SOLUTIONS

  1. _______ or below should be used when trenching and treating with liquid termiticides?ANSWER25 psi
  2. ________ and _______ are both non repellent insecticides?ANSWERneonicotinoids, phenylpyrazole
  3. ________ is the active ingredient that is a repellentANSWERCypermethrin
  4. according to the industry Baseline practices what is the minimum opening size through the truss webbing in the Attic?ANSWER22" x 48"
  5. according to the industry Baseline practices, what is the minimum opening size for an attic entrance?ANSWER20" x 20"

AND 2 EXAM 2025 WITH ACTUAL

CORRECT QUESTIONS AND VERIFIED

DETAILED ANSWERS |FREQUENTLY

TESTED QUESTIONS AND SOLUTIONS

an infestation that is included under a retreatment provision Within ______ of written notification by the property owner or agent?ANSWER30 days

  1. altriset is in which chemical class?ANSWERdiamide
  2. Ambrosia Beetle galleries are formed in the?ANSWERsapwood
  3. Ambrosia beetles leave a dark stain in the wood which is caused by?ANSWERfungus
  4. ArborealANSWERliving in trees. (cone head termite)
  5. as part of the wdo inspection, evidence of a wood destroying organism would not include?ANSWERAmbrosia Beetle stains

AND 2 EXAM 2025 WITH ACTUAL

CORRECT QUESTIONS AND VERIFIED

DETAILED ANSWERS |FREQUENTLY

TESTED QUESTIONS AND SOLUTIONS

  1. attic openings for inspection should be a minimum size of?ANSWER20 in by 20 in
  2. bait station should be installed _____? away from structure and ____? away from each other?ANSWER18 in 20 ft
  3. bark beetles attack green logs and firewood for how many seasons following cuttingANSWER 1 - 2
  4. BASF has developed a treatment method, referred to as EP/LI, which is designed to be non-invasive. It involves a continuous treated Zone along the exterior of the structure and interior treatments only where termites are?ANSWERobserved

AND 2 EXAM 2025 WITH ACTUAL

CORRECT QUESTIONS AND VERIFIED

DETAILED ANSWERS |FREQUENTLY

TESTED QUESTIONS AND SOLUTIONS

  1. hexaflumuron is a _______ termiticide?ANSWERinsect growth regulator
  2. horizontal pre-construction soil treatments are applied at what rate?ANSWER1 gallon per 10 square feet
  3. how do termite alates differ from ants?ANSWERwaist, Wings, exoskeleton
  4. how do you determine an infestation of powder-post termites?ANSWERpellets
  5. how do you treat bark Beetle infested wood?ANSWERburn it
  6. how do you treat foamboard insulation with closed-cell consistency that doesn't allow penetration from surface

AND 2 EXAM 2025 WITH ACTUAL

CORRECT QUESTIONS AND VERIFIED

DETAILED ANSWERS |FREQUENTLY

TESTED QUESTIONS AND SOLUTIONS

application?ANSWERinjection and surface spray

  1. how much damage do carpenter bees cause?ANSWERseldom extensive
  2. how should you minimize termiticide running down slope trenches?ANSWERsteppe the trench
  3. how would you calibrate your application equipment?ANSWERmeasure how much you collect in 1 minute in a graduated container
  4. if you do not properly check any boxes in Section 3 (obstructions and inaccessible areas) on form 13645, then you have indicated that?ANSWERthe area was inspected and considered accessible

AND 2 EXAM 2025 WITH ACTUAL

CORRECT QUESTIONS AND VERIFIED

DETAILED ANSWERS |FREQUENTLY

TESTED QUESTIONS AND SOLUTIONS

  1. Longhorned Beetle
  2. (old house borer)ANSWERCerambycidae
  3. Lyctid beetles do not infest softwood because they lack?ANSWERpores
  4. Pest Control means?ANSWERidentifying pest , mitigate, curb or eradicate any pest
  5. premise is in which chemical class?ANSWERneonicotinoid
  6. recruit HD and trelona baits are in which chemical class?ANSWERchitin synthesis inhibitor
  7. restricted use pesticides are classified as such because?ANSWERthey have the potential to cause harm to humans or the environment, even when used according to the label

AND 2 EXAM 2025 WITH ACTUAL

CORRECT QUESTIONS AND VERIFIED

DETAILED ANSWERS |FREQUENTLY

TESTED QUESTIONS AND SOLUTIONS

  1. Termidor is in which chemical class?ANSWERphenylypyrazole
  2. The eastern sub termite belongs to what family?ANSWERRhinotermitidae
  3. the following are examples of above ground application equipment accepting?ANSWERsub- slab injector
  4. the most likely or common treatment for ppb maybe?ANSWERreplacement of damaged wood
  5. the Old House Borer is a example of?ANSWERLonghorned wood borer
  6. the purpose of the wdo inspection report is to communicate information about the presence

AND 2 EXAM 2025 WITH ACTUAL

CORRECT QUESTIONS AND VERIFIED

DETAILED ANSWERS |FREQUENTLY

TESTED QUESTIONS AND SOLUTIONS

  1. under the definitions as they pertain to wdo inspections, structures would include all of the following but not?ANSWERdetached private fences
  2. under which circumstances may I termite warranty be void?ANSWERconducive conditions not corrected by notified property owner
  3. vertical soil treatments are applied to critical areas at what rate?ANSWER4 gallons per 10 linear feet per foot of depth
  4. what are above ground termite bait stations made of?ANSWERplastic box, bait Matrix, gasket, cover
  5. what class / type of termiticide is Altriset?ANSWERDiamide

AND 2 EXAM 2025 WITH ACTUAL

CORRECT QUESTIONS AND VERIFIED

DETAILED ANSWERS |FREQUENTLY

TESTED QUESTIONS AND SOLUTIONS

  1. what is least likely point of entry for subterranean termites in a house?ANSWERfascia
  2. what is one of the disadvantages of pyrethroid termiticides?ANSWERthey have limited stability in sunlight
  3. what is the advantage of using a soil injection system?ANSWERuse of water readily at site
  4. what is the basic reason to use foam instead of a liquid termiticideANSWERfoam flows around pipes and other debris
  5. what is the difference between restricted and general use pesticides?ANSWERrestricted use products can only be applied by people certified and licensed

AND 2 EXAM 2025 WITH ACTUAL

CORRECT QUESTIONS AND VERIFIED

DETAILED ANSWERS |FREQUENTLY

TESTED QUESTIONS AND SOLUTIONS

  1. what year was the Federal Insecticide Fungicide and rodenticide act enacted?ANSWER 1947
  2. when are you most likely to be exposed two harmful amounts of pesticides?ANSWERmixing and loading
  3. when arriving at a job for a pretreat, who is responsible for notifying the foreman that treatment is going to begin?ANSWERapplicator
  4. When comparing termites to ants for ID you should look for differences in?ANSWERWings, waist, antenna
  5. when doing a termite inspection which is considered a live infestation?ANSWERactual observation of live organisms

AND 2 EXAM 2025 WITH ACTUAL

CORRECT QUESTIONS AND VERIFIED

DETAILED ANSWERS |FREQUENTLY

TESTED QUESTIONS AND SOLUTIONS

  1. when driving to a pre-construction treatment, what should you have with you?ANSWERproduct label
  2. when forced to rod the soil around a structure Rod holes should be?ANSWERno more than 12 in apart
  3. when making termiticide applications in Florida, you must follow which of the following Regulatory Agencies?ANSWERfifra, fdacs, and DEP
  4. When must you use a form 13645 inspection report?ANSWERFor real estate transactions,
  5. and for real estate transactions when a written report is requested
  6. when treating for subterranean termites at a property with an accessible crawl space, where

AND 2 EXAM 2025 WITH ACTUAL

CORRECT QUESTIONS AND VERIFIED

DETAILED ANSWERS |FREQUENTLY

TESTED QUESTIONS AND SOLUTIONS

  1. which agency established regulations for Pest and rodent controlANSWERfifra
  2. which are considered part of a structureANSWERhousehold contents
  3. which are defined as wdo by state statutes? FS 482ANSWERtermites, powder post beetles, old house borers, wood decaying fungi
  4. which are neonicotinoid pesticides?ANSWERImidacloprid, thiamethoxam
  5. which are the two categories of application equipment used for subterranean termites soil treatments?ANSWERabove-ground and below- ground

AND 2 EXAM 2025 WITH ACTUAL

CORRECT QUESTIONS AND VERIFIED

DETAILED ANSWERS |FREQUENTLY

TESTED QUESTIONS AND SOLUTIONS

  1. which are the two documents that can give you guidance on completing a form 13645 inspection report?ANSWERThe industry baseline practices and the guidelines for the use and completion of the form 13645
  2. which area would be most susceptible to termites entering the structure?ANSWERadjoining slab
  3. which Beatle prefers high moisture or poor ventilation?ANSWERanobiid
  4. which best describes drywood termites?ANSWERgalleries Underwood surface
  5. which describes a spot treatment?ANSWERtreatment of specific areas