A comprehensive overview of fire sprinkler systems, covering their operation, maintenance, and regulations. It delves into various types of sprinkler systems, including wet pipe, dry pipe, preaction, and deluge systems, explaining their unique features and applications. The document also outlines the responsibilities of building owners and managers in ensuring the proper functioning of sprinkler systems, including regular inspections, testing, and maintenance. It emphasizes the importance of compliance with fire codes and regulations, highlighting potential consequences of non-compliance. This document serves as a valuable resource for understanding the intricacies of fire sprinkler systems and their role in fire safety.
Typology: Exams
1 / 32
This page cannot be seen from the preview
Don't miss anything!
normally on exterior of building... FDNY can pump supplemental water into the sprinkler system, standpipe, or other system furnishing water for fire extinguishment to supplement existing water supplies. system control valve valve controlling flow to water-based fire protection systems. fire command center Designated room or area in a structure where the status of the fire detection, alarm, and protection systems is displayed and the systems can be manually controlled. Fire pump, automatic standpipe. A fire pump located at or below street level that supplies the lower 300 feet (91.4 m) of a standpipe system or a combined standpipe and sprinkler system. tags on closed section valves serving affected areas: area affected, brief description, occupancy classification, c of f number, estimated time until operational Green tag no impairment found in entire system- main control valve red tag place on main control valve if FULLY out of service... put sprinkler company name, date of removal from service and anticipated time to operational
blue disk partially out of service- on all fire department connections water storage tank Collects cooled water OS & Y valve indicating type of control valve used for fire sprinkler system deluge valve water supply control valve intended to be operated by actuation of an automatic detection system that is installed in the same area as the discharge devices. INTENDED USE IS MANUAL AND AUTO deluge sprinkler system employing open sprinklers that are attached to a piping system that is connected to a water supply through a valve that is opened by the operation of a detection system installed in the same areas as the sprinklers. WHEN IT OPENS, water flows into the piping system and discharges from all sprinklers attached. Early suppresion fast response sprinklers fast response sprinkler that is listed for its capability to provide fire suppression of specific high challenge fire hazards