






Study with the several resources on Docsity
Earn points by helping other students or get them with a premium plan
Prepare for your exams
Study with the several resources on Docsity
Earn points to download
Earn points by helping other students or get them with a premium plan
Community
Ask the community for help and clear up your study doubts
Discover the best universities in your country according to Docsity users
Free resources
Download our free guides on studying techniques, anxiety management strategies, and thesis advice from Docsity tutors
A comprehensive overview of the fdnyc g60 practice exam, covering topics such as the requirements for a certificate of fitness, the proper handling and storage of flammable gases, fire safety protocols, and the responsibilities of a certificate of fitness holder. Detailed information on the types of fires, fire extinguishers, hot work permits, and the proper procedures for conducting torch operations. It also covers important safety considerations, such as the need for proper ventilation, the dangers of ice buildup on gas cylinders, and the importance of maintaining and inspecting equipment. This document would be highly valuable for individuals seeking to obtain a certificate of fitness or those who work with flammable gases and need to ensure compliance with fdny regulations.
Typology: Exams
1 / 11
This page cannot be seen from the preview
Don't miss anything!
All torch operators, an oxigen-fuel torch using any amount of oxigen and flamable gas and fire guards must have a current - 🔷ANSWERS 🖊✔✔ Certificate of Fitness The Certificate of Fitness holder - 🔷ANSWERS 🖊✔✔ must regulate the pressure and flow of oxygen and natural gas to each torch. if the torch operator for jewelry manufacture involves - 🔷ANSWERS 🖊✔✔ any oxygen with any fuel gas containers, the operator must be a C of F holder. A Certificate of Fitness Holder must keep his or her certificate - 🔷ANSWERS 🖊✔✔ on their person or otherwise readily available for inspection by any representative of the fire Department The easiest way to extinguish a fire caused by a leak is to - 🔷ANSWERS 🖊✔✔ close the shutoff valve Permits issued by the FDNY are required to conduct the following hot work: - 🔷ANSWERS 🖊✔✔ storing, using or handling oxygen and a flammable gas, storing, using or handling any flammable gas (e.g. LPG or CNG or acetylene) in excess of 400 SCF. Storing, using or handling any oxidizing gas (e.g. oxygen) in excess of 504 SCF. For LPG, 400 SCF is - 🔷ANSWERS 🖊✔✔ approximately 47 lbs the number of LPG containers for the storage, use, handling or transportation, requiring a permit - 🔷ANSWERS 🖊✔✔ 14.1 oz = 54 cont. 16.4 oz = 46 cont. 20 lbs = 3 cont.
33.5 lbs = 2 cont. 40 lbs = 2 cont. 100 lbs = 1 cont. Portable LPG containers that are more than 16.4 oz and CNG containers with a capacity greater than 8.7 SCF - 🔷ANSWERS 🖊✔✔ must NOT stored, handled, or used indoors in the following occupancies (as defined in the Building code): residential occupancies, factory and industrial occupancies; educational occupancies; institutional occupancies, except as the commissioner may authorize by rule. Site-specific permit - 🔷ANSWERS 🖊✔✔ may be a permanent permit or a temporary permit. Permanent permits are valid for 12 months only A city-wide permit is valid - 🔷ANSWERS 🖊✔✔ up to 30 days Permits shall be - 🔷ANSWERS 🖊✔✔ readily available on the premise for inspection by Fire Department representatives. Hot work authorization should be issued by the responsible person, and it - 🔷ANSWERS 🖊✔✔ must be available for inspection by any representative of the department during the performance of the work, and for 48 hours after the work is complete FDNY permits - 🔷ANSWERS 🖊✔✔ will be posted in a central location and recorded in a log book to assist in the coordination of construction related activities. CNG - 🔷ANSWERS 🖊✔✔ Compressed Natural Gas. For Citywide hot work operations, the Owner of the premises must be notified in writing at least _____ hours in advance prior to work beginning. - 🔷ANSWERS 🖊✔✔ 48 A class A fire extinguisher fights fires from - 🔷ANSWERS 🖊✔✔ Paper
PASS stands for - 🔷ANSWERS 🖊✔✔ Pull, Aim, Squeeze, Sweep In the case of any fire, - 🔷ANSWERS 🖊✔✔ The FDNY must be notified For piped gas, - 🔷ANSWERS 🖊✔✔ the gas should be shut off first Oxygen cylinders are made of - 🔷ANSWERS 🖊✔✔ Steel A temporary permit to conduct torch operations is valid from - 🔷ANSWERS 🖊✔✔ 1 day to 12 months A hot work permit is required for - 🔷ANSWERS 🖊✔✔ welding A spark producing tool - 🔷ANSWERS 🖊✔✔ requires a Fire Guard Soldering and brazing temperatures are typically - 🔷ANSWERS 🖊✔✔ 840 degrees Fahrenheit Oxy-Acetylene can generate a temperature of up to - 🔷ANSWERS 🖊✔✔ 6000 degrees Fahrenheit An area exposed to sparks, hot slag, radiant heat, or convective heat as a result of welding is called a - 🔷ANSWERS 🖊✔✔ Hot Work Area A person holding a Certificate of Fitness who is trained and responsible for maintaining a fire watch is known as a - 🔷ANSWERS 🖊✔✔ Fire Guard Most fires are the result of - 🔷ANSWERS 🖊✔✔ sparks What should you do if ice buildup occurs on the gas cylinder itself? - 🔷ANSWERS 🖊 ✔✔call 911 immediately
If a Certificate of Fitness holder discovers that an oxygen regulator is defective, they should - 🔷ANSWERS 🖊✔✔ take it out of service If a gas container is unmarked, the certificate of fitness holder should - 🔷ANSWERS 🖊 ✔✔take the cylinder out of service What tank condition would be cause to remove it from service? - 🔷ANSWERS 🖊✔✔ the pressure relief valve shows visible damage A control valve should be - 🔷ANSWERS 🖊✔✔ opened by hand Persons conducting Torch Operations must possess a current - 🔷ANSWERS 🖊✔✔ G- Certificate of Fitness A rapid, persistent chemical reaction that releases heat and light, especially the burning of a combustible substance in the presence of oxygen. - 🔷ANSWERS 🖊✔✔ A Fire A class B fire extinguisher fights fires from - 🔷ANSWERS 🖊✔✔ oil A written statement issued by the commissioner certifying that the person to whom it is issued has passed an examination as to his or her qualifications or is otherwise deemed qualified to use or supervise the storage, handling and use of a material - 🔷ANSWERS 🖊✔✔ Certificate of Fitness What type of fire is a Class A fire extinguisher used on? - 🔷ANSWERS 🖊✔✔ cardboard An example of a flammable material would be - 🔷ANSWERS 🖊✔✔ kerosene Fire extinguishers must be maintained by a W-96 Certificate of Fitness holder every - 🔷ANSWERS 🖊✔✔ year
A Citywide permit is valid for up to - 🔷ANSWERS 🖊✔✔ 30 Days A hot work permit is required for - 🔷ANSWERS 🖊✔✔ Welding. A spark producing tool - 🔷ANSWERS 🖊✔✔ Requires a Fire Guard. To prevent injury hoses should be - 🔷ANSWERS 🖊✔✔ As short as practical. The oxygen cylinder - 🔷ANSWERS 🖊✔✔ is made of steel and contains 100% oxygen. A compressed gas container must - 🔷ANSWERS 🖊✔✔ Not be rolled on its side. An area exposed to sparks, hot slag, radiant heat, or convective heat as a result of welding is called a - 🔷ANSWERS 🖊✔✔ Hot work area. Fuel gas or oxygen containers in storage must be separated from any combustible materials by a minimum distance of - 🔷ANSWERS 🖊✔✔ 20 feet. Most fires are the result of - 🔷ANSWERS 🖊✔✔ Sparks. Sparks and pieces of hot metal are the source of ignition in about______ of fires in industrial occupancies. - 🔷ANSWERS 🖊✔✔ 60. Under no circumstances can hot work be performed within _____ feet of flammable or explosive materials. - 🔷ANSWERS 🖊✔✔ 35. If torch operation is to be discontinued for a period of ___________, the torch valve must be closed and the gas supply to the torch must be completely shut. - 🔷ANSWERS 🖊 ✔✔One hour or more. A torch should be ignited by using a - 🔷ANSWERS 🖊✔✔ Friction device.
Why should oil or grease not be used near oxygen? - 🔷ANSWERS 🖊✔✔ It might cause an explosion. How long is a site permanent specific permit to store flammable gases valid for? - 🔷ANSWERS 🖊✔✔ 30 days How many Fire Guards are required on a job site that has 3 torches in operation? - 🔷ANSWERS 🖊✔✔ One per torch and additional one stationed on the floor below. Portable LPG containers greater than ______ must not be stored in residential occupancies. - 🔷ANSWERS 🖊✔✔ 16.4 oz. An oxygen cylinder may store gas at pressure up to - 🔷ANSWERS 🖊✔✔ 2200 psi. A Responsible Person is one who is - 🔷ANSWERS 🖊✔✔ trained in the fire safety hazards associated with hot work, and in the necessary and appropriate measures to minimize those hazards, who is designated by the owner of a premises to authorize the performance of hot work at the premises. A designated Hot Work area must be at least_______ feet away from combustible materials. - 🔷ANSWERS 🖊✔✔ 35. For all Hot Work, inspections must be completed_______ after completion of torch operations. - 🔷ANSWERS 🖊✔✔ 30 minutes. A minimum ___________ rating Fire Extinguisher must be readily accessible within ________ of the hot work location for torch operations. - 🔷ANSWERS 🖊✔✔ 2-A:20-B:C, 30 feet. For a Torch-applied Roof System, a minimum ___________ rating Fire Extinguisher must be readily accessible within ________. - 🔷ANSWERS 🖊✔✔ 3-A: 40-B:C, 30 feet.
Double Action fire alarm pull station - 🔷ANSWERS 🖊✔✔ Double Action fire alarm pull station- requires the user to take two steps in order to activate the alarm such as lifting a cover and then pulling a lever. This type of alarm is commonly used outside. All gas containers and the related equipment - 🔷ANSWERS 🖊✔✔ must be protected from extreme temperature and physical damage. Any single standard portable LPG container must not exceed - 🔷ANSWERS 🖊✔✔ 100 lbs in weight. Any single CNG container must not exceed - 🔷ANSWERS 🖊✔✔ 381 SCF. Permits shall be readily available on the premise for inspection by - 🔷ANSWERS 🖊 ✔✔Fire Department representatives. NFPA stands for - 🔷ANSWERS 🖊✔✔ National Fire Protection Association. Most common fuel gases used in blowtorches are - 🔷ANSWERS 🖊✔✔ LPG (e.g. butane, propane), natural gas (methane) (either CNG or piped natural gas). A fire guard is responsible for - 🔷ANSWERS 🖊✔✔ overseeing torch operations. The pre-hot work check must be conducted by - 🔷ANSWERS 🖊✔✔ the responsible person before hot work is authorized and at least once per day. The check reports must be kept at the work site - 🔷ANSWERS 🖊✔✔ maintained on the premises for a minimum of 48 hours after work is complete. Exhaust fans - 🔷ANSWERS 🖊✔✔ may be used to draw the fumes away from the work area
The workers should - 🔷ANSWERS 🖊✔✔ wear flame resistant gloves and aprons and should not be worm Clothing with pockets or cuffs