FDNYC G60 Practice Exam tested questions with revised correct answers, (a+ guarantee), Exams of Safety and Fire Engineering

1. FDNY G60 Fire Guard exam study materials 2. How to prepare for FDNY G60 Fire Guard test 3. FDNY G60 Fire Guard exam practice questions 4. FDNY G60 Fire Guard certification requirements 5. FDNY G60 Fire Guard exam passing score 6. FDNY G60 Fire Guard exam scheduling process 7. FDNY G60 Fire Guard exam retake policy 8. FDNY G60 Fire Guard exam locations in NYC 9. FDNY G60 Fire Guard exam fees and payment options 10. FDNY G60 Fire Guard exam duration and format 11. FDNY G60 Fire Guard exam topics and syllabus 12. FDNY G60 Fire Guard exam online registration 13. FDNY G60 Fire Guard exam preparation courses 14. FDNY G60 Fire Guard exam sample questions PDF 15. FDNY G60 Fire Guard exam study guide download 16. FDNY G60 Fire Guard exam tips and tricks 17. FDNY G60 Fire Guard exam renewal process 18. FDNY G60 Fire Guard exam for non-English speakers 19. FDNY G60 Fire Guard exam accommodations for disabilities

Typology: Exams

2024/2025

Available from 06/09/2025

stacey-studyguide
stacey-studyguide ๐Ÿ‡บ๐Ÿ‡ธ

509 documents

1 / 14

Toggle sidebar

This page cannot be seen from the preview

Don't miss anything!

bg1
1 / 7
FDNYC G60 Practice Exam Questions And Answers
(Verified Answers)
1. All torch operators, an oxigen-fuel torch using any amount of oxigen and flamable gas and fire
guards must have a currentโœ”โœ”โœ” Certificate of Fitness
2. The Certificate of Fitness holderโœ”โœ”โœ” must regulate the pressure and flow of oxygen and
natural gas to each torch.
3. if the torch operator for jewelry manufacture involvesโœ”โœ”โœ” any oxygen with any fuel gas containers,
the operator must be a C of F holder.
4. A Certificate of Fitness Holder must keep his or her certificateโœ”โœ”โœ” on their person or otherwise
readily available for inspection by any representative of the fire Department
5. The easiest way to extinguish a fire caused by a leak is toโœ”โœ”โœ” close the shutoff valve
6. Permits issued by the FDNY are required to conduct the following hot workโœ”โœ”โœ”โœ”โœ”โœ” storing,
using or handling oxygen and a flammable gas, storing, using or handling any flammable gas (e.g. LPG
or CNG or acetylene) in excess of
400 SCF. Storing, using or handling any oxidizing gas (e.g. oxygen) in excess of 504 SCF.
7. For LPG, 400 SCF isโœ”โœ”โœ” approximately 47 lbs
pf3
pf4
pf5
pf8
pf9
pfa
pfd
pfe

Partial preview of the text

Download FDNYC G60 Practice Exam tested questions with revised correct answers, (a+ guarantee) and more Exams Safety and Fire Engineering in PDF only on Docsity!

FDNYC G60 Practice Exam Questions And Answers

(Verified Answers)

1. All torch operators, an oxigen-fuel torch using any amount of oxigen and flamable gas and fire

guards must have a current โœ”โœ”โœ” Certificate of Fitness

2. The Certificate of Fitness holder โœ”โœ”โœ” must regulate the pressure and flow of oxygen and

natural gas to each torch.

3. if the torch operator for jewelry manufacture involves โœ”โœ”โœ” any oxygen with any fuel gas containers,

the operator must be a C of F holder.

4. A Certificate of Fitness Holder must keep his or her certificate โœ”โœ”โœ” on their person or otherwise

readily available for inspection by any representative of the fire Department

5. The easiest way to extinguish a fire caused by a leak is to โœ”โœ”โœ” close the shutoff valve

6. Permits issued by the FDNY are required to conduct the following hot work โœ”โœ”โœ”โœ”โœ”โœ” storing,

using or handling oxygen and a flammable gas, storing, using or handling any flammable gas (e.g. LPG or CNG or acetylene) in excess of 400 SCF. Storing, using or handling any oxidizing gas (e.g. oxygen) in excess of 504 SCF.

7. For LPG, 400 SCF is โœ”โœ”โœ” approximately 47 lbs

8. the number of LPG containers for the storage, use, handling or transporta- tion, requiring a

permit โœ”โœ”โœ” 14.1 oz = 54 cont. 16.4 oz = 46 cont. 20 lbs = 3 cont. 33.5 lbs = 2 cont. 40 lbs = 2 cont. 100 lbs = 1 cont.

9. Portable LPG containers that are more than 16.4 oz and CNG containers with a capacity greater

than 8.7 SCF โœ”โœ”โœ” must NOT stored, handled, or used indoors in the following occupancies (as defined in the Building code)residential occu- pancies, factory and industrial occupancies; educational occupancies; institutional occupancies, except as the commissioner may authorize by rule.

10. Site-specific permit โœ”โœ”โœ” may be a permanent permit or a temporary permit. Permanent

permits are valid for 12 months only

11. A city-wide permit is valid โœ”โœ”โœ” up to 30 days

12. Permits shall be โœ”โœ”โœ” readily available on the premise for inspection by Fire Department

representatives.

22. Fire extinguishers must be inspected once every โœ”โœ”โœ” Month

23. A work area should be โœ”โœ”โœ” Well Ventilated

24. A type C fire involves โœ”โœ”โœ” Live electrical equipment

25. Automatic sprinkler heads should be โœ”โœ”โœ” covered by a damp cloth and removed after hot work

26. A permit is required for storing a flammable gas in excess of โœ”โœ”โœ” 400 scf

27. Acetylene burns at โœ”โœ”โœ” 3000 degrees Fahrenheit

28. It is dangerous to use fuel gas at pressures above โœ”โœ”โœ” 15 psi

29. A fire extinguisher must be mounted โœ”โœ”โœ” so that the top is not more than 5 feet off the floor

30. To extinguish a fire โœ”โœ”โœ” Always approach the fire from upwind

31. PASS stands for โœ”โœ”โœ” Pull, Aim, Squeeze, Sweep

32. In the case of any fire, โœ”โœ”โœ” The FDNY must be notified

33. For piped gas, โœ”โœ”โœ” the gas should be shut off first

34. Oxygen cylinders are made of โœ”โœ”โœ” Steel

35. A temporary permit to conduct torch operations is valid from โœ”โœ”โœ” 1 day to 12 months

50. A class B fire extinguisher fights fires from โœ”โœ”โœ” oil

51. A written statement issued by the commissioner certifying that the per- son to whom it is

issued has passed an examination as to his or her quali- fications or is otherwise deemed qualified to use or supervise the storage, handling and use of a material โœ”โœ”โœ” Certificate of Fitness

52. What type of fire is a Class A fire extinguisher used on? โœ”โœ”โœ” cardboard

53. An example of a flammable material would be โœ”โœ”โœ” kerosene

54. Fire extinguishers must be maintained by a W-96 Certificate of Fitness holder every โœ”โœ”โœ” year

55. A type D fire involves โœ”โœ”โœ” Combustible Metals

56. A type of clothing that should not be worn when performing torch oper- ations is โœ”โœ”โœ” Frayed

Clothing.

57. A flame going out unexpectedly and creating a popping sound is known as โœ”โœ”โœ” Backfire.

58. When a cutting or welding flame burns inside a torch is known as โœ”โœ”โœ” Flash- back.

59. To check for a leak one should โœ”โœ”โœ” Use a soap and water solution.

60. A work area should be โœ”โœ”โœ” Well ventilated.

61. To extinguish a fire โœ”โœ”โœ” Always approach the fire from upwind.

62. How should a gas cylinder be stored? โœ”โœ”โœ” Upright and not on shelves.

63. In the case of any fire, โœ”โœ”โœ” The FDNY must be notified.

64. Acetylene valves should not be opened more than โœ”โœ”โœ” 1 1/2 turns

65. "SCF" stands for โœ”โœ”โœ” Standard Cubic Feet

66. A Certificate of Fitness Holder must keep his or her certificate โœ”โœ”โœ” On their person.

67. A Citywide permit is valid for up to โœ”โœ”โœ” 30 Days

68. A hot work permit is required for โœ”โœ”โœ” Welding.

69. A spark producing tool โœ”โœ”โœ” Requires a Fire Guard.

70. To prevent injury hoses should be โœ”โœ”โœ” As short as practical.

71. The oxygen cylinder โœ”โœ”โœ” is made of steel and contains 100% oxygen.

78. If torch operation is to be discontinued for a period of ,

the torch valve must be closed and the gas supply to the torch must be completely shut. โœ”โœ”โœ” One hour or more.

79. A torch should be ignited by using a โœ”โœ”โœ” Friction device.

80. Why should oil or grease not be used near oxygen? โœ”โœ”โœ” It might cause an explosion.

81. How long is a site permanent specific permit to store flammable gases valid for? โœ”โœ”โœ” 30 days

82. How many Fire Guards are required on a job site that has 3 torches in operation? โœ”โœ”โœ” One

per torch and additional one stationed on the floor below.

83. Portable LPG containers greater than must not be stored in

residential occupancies. โœ”โœ”โœ” 16.4 oz.

84. An oxygen cylinder may store gas at pressure up to โœ”โœ”โœ” 2200 psi.

85. A Responsible Person is one who is โœ”โœ”โœ” trained in the fire safety hazards associated with hot

work, and in the necessary and appropriate measures to minimize those hazards, who is designated by the owner of a premises to authorize the performance of hot work at the premises.

86. A designated Hot Work area must be at least feet away from

combustible materials. โœ”โœ”โœ” 35.

87. For all Hot Work, inspections must be completed after completion of

torch operations. โœ”โœ”โœ” 30 minutes. .

88. Empty compressed gas cylinders โœ”โœ”โœ” Should be handled in the same manner as full ones.

89. Panic Bar โœ”โœ”โœ” A device fitted on the inside of a door that would allow a person to push against a

door to open it.

90. A type of valve typically used in sprinkler systems โœ”โœ”โœ” OS & Y Valve- Outside Screw and Yoke

Valve.

103. NFPA stands for โœ”โœ”โœ” National Fire Protection Association.

104. Most common fuel gases used in blowtorches are โœ”โœ”โœ” LPG (e.g. butane, propane), natural

gas (methane) (either CNG or piped natural gas).

105. A fire guard is responsible for โœ”โœ”โœ” overseeing torch operations.

106. The pre-hot work check must be conducted by โœ”โœ”โœ” the responsible person before hot work is

authorized and at least once per day.

107. The check reports must be kept at the work site โœ”โœ”โœ” maintained on the premises for a

minimum of 48 hours after work is complete.

108. Exhaust fans โœ”โœ”โœ” may be used to draw the fumes away from the work area

109. The workers should โœ”โœ”โœ” wear flame resistant gloves and aprons and should not be worm Clothing

with pockets or cuffs