Docsity
Docsity

Prepare for your exams
Prepare for your exams

Study with the several resources on Docsity


Earn points to download
Earn points to download

Earn points by helping other students or get them with a premium plan


Guidelines and tips
Guidelines and tips

FDNYC G60 Practice Exam tested questions (latest 2025 / 2026) with verified answers, Exams of Safety and Fire Engineering

FDNYC G60 Practice Exam tested questions (latest 2025 / 2026) with verified answers FDNY G60 fire guard test questions G60 fire guard exam answers 2025 FDNY fire guard test prep 2026 latest G60 fire guard practice questions verified G60 fire guard answers FDNY G60 exam study guide G60 fire guard certification test 2025 G60 fire guard questions and answers FDNY G60 fire guard exam help G60 fire guard test preparation New York G60 fire guard sample test FDNY G60 fire guard training materials G60 fire guard licensing exam questions 2026 FDNY G60 fire guard test latest G60 fire guard exam prep fire guard test FDNY G60 questions FDNY fire guard G60 exam tips G60 fire guard test practice 2025 best G60 fire guard study resources FDNY G60 exam practice questions

Typology: Exams

2024/2025

Available from 02/25/2025

smartdove-1
smartdove-1 🇺🇸

2

(2)

1.3K documents

1 / 8

Toggle sidebar

This page cannot be seen from the preview

Don't miss anything!

bg1
1 / 3
FDNYC G60 Practice Exam Questions and Answers
(Verified Answers)
1. The pre-hot work check must be conducted by the responsible person...-
ANS Once per day
2. Piped gas lines should be... ANS Shut off if there is a fire
3. Don't aim the fire extinguisher at... ANS center of the flame
4. When it is not possible to shut off a gas supply and the gas supply
is limited, you should.... ANS allow the fire to burn itself out and call
911
5. Trained Certificate of Fitness holders should only attempt to
extinguish fires that are.... ANS limited in size and can be readily
pf3
pf4
pf5
pf8

Partial preview of the text

Download FDNYC G60 Practice Exam tested questions (latest 2025 / 2026) with verified answers and more Exams Safety and Fire Engineering in PDF only on Docsity!

FDNYC G60 Practice Exam Questions and Answers

(Verified Answers)

1. The pre-hot work check must be conducted by the responsible person...- ANS Once per day

  1. Piped gas lines should be... ANS Shut off if there is a fire
  2. Don't aim the fire extinguisher at... ANS center of the flame
  3. When it is not possible to shut off a gas supply and the gas supply is limited, you should.... ANS allow the fire to burn itself out and call 911
  4. Trained Certificate of Fitness holders should only attempt to extinguish fires that are.... ANS limited in size and can be readily

extinguished

  1. Class A fire are caused by... ANS ordinary combustible materials
  2. Class B fire are caused by... ANS flammable or combustible liquids
  3. Class C fires are caused by... ANS electrical equipment
  4. Class D fires are caused by... ANS ignitable metals
  5. Flames must be approached from a position. ANS upwind
  6. Never approach a flame from a position. ANS downwind
  7. Never point a fire extinguisher at the... ANS center of the flame
  8. You must point a fire extinguisher at where... ANS the flame begins
  1. The use of nonmetallic pipe tubing, or hose for permanently interconnect- ing gas containers is. ANS prohibited
  2. Generally speaking, nonmetallic pipe, tubing and components for any in- stallation, appliance or equipment using LPG or CNG is prohibited. However, nonmetallic hose may be allowed at. ANS construction sites
  3. Hoses must be protected from and no hose is allowed to exceed feet. ANS physical damage, 30
  4. What is Flashback? ANS when a flame burns inside a torch or hose
  5. When Flashback happens and there is a hissing/whistling noise, what should you do? ANS close control valves, close gas container
  6. What is Backfire? ANS when the flame on a torch goes out unexpectedly
  1. An Acetylene container valve must not be turned more than turns. ANS 1 ½
  2. Soldering and Brazing temperatures are typically F ANS 840 28. For any CNG or LPG torch operation, the first inspection shall be conduct- ed minutes after completion of torch operations; the second inspection hour after completion of torch operations. ANS 30, 1
  3. For any CNG or LPG torch operation, the FIRST inspection shall be conducted minutes after completion of torch operations ANS 30
  4. For any CNG or LPG torch operation, the SECOND inspection shall be conducted hour after completion of torch operations ANS 1
  5. The inspection report must be made available to any representative of the Fire Department and should be maintained on the premises for... ANS 48 hours
  6. Torch Applied Roof-System ANS Bituminous roofing systems using membranes that are adhered by heating with a torch and melting asphalt back coating instead of mopping hot asphalt for adhesion.
  7. It shall be unlawful to install any roofing material using a torch on a
  1. The pre-hot work check must be conducted by the before hot work is authorized and at least once per day. ANS responsible person
  2. A pre-hot work check must be conducted at least per day ANS once
  3. What is hot work? ANS Cutting, welding, thermit welding, brazing, soldering, grinding, thermal spraying, thawing pipe, cadwelding, installation of torch-applied system, or any other similar operation or activity.
  4. What is a Fire Guard? ANS A person holding a Certificate of Fitness for such purposes, who is trained in and responsible for maintaining a fire watch and performing such fire safety duties as may be prescribed by the commissioner.
  5. What is a Fire Watch? ANS A temporary measure intended to ensure continuous and systematic surveillance of a building or portion thereof by one or more qualified individuals for the purposes of identifying and controlling fire hazards, detecting early signs of fire, raising an alarm of fire, and notifying the department.
  6. What does NFPA stand for and what does it do? ANS National Fire Protection Association. NFPA develops, publishes, and disseminates more than 300 consen- sus codes and standards intended to minimize the

possibility and effects of fire and other risks.