Docsity
Docsity

Prepare for your exams
Prepare for your exams

Study with the several resources on Docsity


Earn points to download
Earn points to download

Earn points by helping other students or get them with a premium plan


Guidelines and tips
Guidelines and tips

Fdnyc G60 Fire Guard tested questions with revised correct answers a+ guarantee), Exams of Safety and Fire Engineering

1. FDNY G60 Fire Guard exam study materials 2. How to prepare for FDNY G60 Fire Guard test 3. FDNY G60 Fire Guard exam practice questions 4. FDNY G60 Fire Guard certification requirements 5. FDNY G60 Fire Guard exam passing score 6. FDNY G60 Fire Guard exam scheduling process 7. FDNY G60 Fire Guard exam retake policy 8. FDNY G60 Fire Guard exam locations in NYC 9. FDNY G60 Fire Guard exam fees and payment options 10. FDNY G60 Fire Guard exam duration and format 11. FDNY G60 Fire Guard exam topics and syllabus 12. FDNY G60 Fire Guard exam online registration 13. FDNY G60 Fire Guard exam preparation courses 14. FDNY G60 Fire Guard exam sample questions PDF 15. FDNY G60 Fire Guard exam study guide download 16. FDNY G60 Fire Guard exam tips and tricks 17. FDNY G60 Fire Guard exam renewal process 18. FDNY G60 Fire Guard exam for non-English speakers 19. FDNY G60 Fire Guard exam accommodations for disabilities

Typology: Exams

2024/2025

Available from 06/09/2025

stacey-studyguide
stacey-studyguide šŸ‡ŗšŸ‡ø

509 documents

1 / 61

Toggle sidebar

This page cannot be seen from the preview

Don't miss anything!

bg1
1 / 30
FDNYC G60 FIRE GUARD STUDY QUESTIONS & ANSWERS
1. G-60
: Use of oxygen and flammable gasses, or LPG or CNG for any hot work
2. COF exception
: Torch operations for jewelry
3. FDNY permit
: Storing using or handling oxygen and flammable gas
in excess of 400scf (LPG, CNG or scetylene)
oxidizing gass in excess of 504scf
4. Portable LPG must not be stored when the capacity of the container is greater than
?: 16.4 oz
pf3
pf4
pf5
pf8
pf9
pfa
pfd
pfe
pff
pf12
pf13
pf14
pf15
pf16
pf17
pf18
pf19
pf1a
pf1b
pf1c
pf1d
pf1e
pf1f
pf20
pf21
pf22
pf23
pf24
pf25
pf26
pf27
pf28
pf29
pf2a
pf2b
pf2c
pf2d
pf2e
pf2f
pf30
pf31
pf32
pf33
pf34
pf35
pf36
pf37
pf38
pf39
pf3a
pf3b
pf3c
pf3d

Partial preview of the text

Download Fdnyc G60 Fire Guard tested questions with revised correct answers a+ guarantee) and more Exams Safety and Fire Engineering in PDF only on Docsity!

FDNYC G60 FIRE GUARD STUDY QUESTIONS & ANSWERS

1. G-

: Use of oxygen and flammable gasses, or LPG or CNG for any hot work

2. COF exception

: Torch operations for jewelry

3. FDNY permit

: Storing using or handling oxygen and flammable gas in excess of 400scf (LPG, CNG or scetylene) oxidizing gass in excess of 504scf

4. Portable LPG must not be stored when the capacity of the container is greater than

?: 16.4 oz

5. Portable CNG containers must not be stored then the capacity is greater than

?: 8.7 SCF

6. Single standard portable LPG containers must not exceed

?: 100LBs in weight

7. Single CNG containers must not exceed

?: 381 SCF

8. LPG

400 SCF is approximately : 47 lbs

9. Types of FDNY permits

: Site specific permits City wide permits Transportation permits

?: 5 gals gasoline 250 gals of flammable 300 gals combustible liquid

15. Transportation permit: FDNY approved inspected displayed on vehicle

16. Hot work authorization.: Required for any project with hot work operation but not issued by the FDNY

17. Responsible person: Must be available for inspection by any representative of fire department

during and 48 hours after the work is complete.

18. Fire guard: Cof holder who is trained in and responsible for maintaijjng a fire watch.

19. Fire watch: Survailance of an area Detect

signs of early fire Raise alarms Notify department

20. Pre hot work check must be conducted by the responsible person before hot work is

authorized at least?: Once per day

21. Pre hot work check daily and must very the following: Equipment working in order

Hot work is clear of combistibles and flammable solids Combustible and non combustible are protected Fire watch personel are assigned Fire extinguisher available

22. Fire watch: A fire watch must be maintained during any hot work operation.

23. The person conducting a fire watch shall: Not have other duties

24. Fire watch

At least one portable fire extinguisher with a: Minimum 2-A:20-B:C rating shall be accessible within 30ft from hot work

Buildings and structures Rooftops

27. Fire watch must continue for: 30 minutes after the conclusing of the work.

28. Time and record keeping requirements

CNG or LPG torch operations inspections: First shall be conducted 30minute after completion Second inspection 1 hour after completion

29. The inspection report must be available: 48 hours after work is complete for fire department

representative to look over.

30. Oxygen cylinder is made of: Steel and contains 100% oxygen

31. Oxy propane degrees: 1,500 degrees

32. Acetylene degrees: 3000 degrees

33. Oxy-acetylene degrees: 6000 degrees

34. Brazing and soldering temperatures: Typically 840 degrees

35. Oxy-fuel torch

Oxygen storage pressures up to: 2200 PSI (pounds per square inch)

36. Oxy-fuel torch

Dangerous fuel gas pressures: Above 15 psi especially for acetylene

37. Gas torches also have applications and additions like: For burning weeds Melting ice

Applying tar/asphalt

38. Backfire: Flame on torch goes out unexpectedly

A loud snap or pop may occur when the flame goes out.

39. Flashback: Cutting or welding flame burns inside the torch or the hoses. It is usually accompanied by

a whistling or hissing noise.

40. Frayed clothing: Susceptible to ignition and burning, should not be worn.

51. oxygen-fuel gas torches have two separate containers:: a pressurized fuel gas container and a

pressurized oxygen container.

52. The oxygen cylinder: made of steel and contains 100% oxygen.

53. A mixture of oxygen and a fuel gas is used to: generate a flame

54. oxygen intensifies: the burning of the fuel gas.

55. Oxy-propane torches can produce about degrees Fahrenheit high- er than

the air-propane torch can generate: 1,

56. Acetylene is used because: compared to the other fuel gases it creates the greatest amount of heat

when burned (i.e. 3,000 degrees Fahrenheit higher than an air-propane torch)

57. Both gas containers have control valves on the of the container.: top

58. The valves control the: discharge of gas from the containers

59. Gas containers also have a: protective cap or protective collar.

60. when the cylinders are not in use: The caps should be screwed on over the valve

61. The oxygen is stored at pressures up to: 2200 psi

62. The fuel gas is stored at higher pressures to keep: sufficient amount of fuel available for torch

operations

63. it is dangerous to use the fuel gas at pressures above psi, especially for

: 15, acetylene.

64. The regulator makes sure that: fuel is discharged from the gas container at a safe pressure range

65. The two gases, and the , are mixed inside the torch: -

oxygen, fuel gases

66. Adjusting the valves controls:: the shape and intensity of the flame.

67. Welding involves: joining two or more pieces of metal together to form a single piece.

68. cutting processes involve: separating or severing a piece of metal through intense heat generated

73. PERMITS SHALL BE READILY AVAILABLE ON THE FOR IN-

SPECTION BY FIRE DEPARTMENT REPRESENTATIVES.: PREMISES

74. HOT WORK PERMITS SHALL BE AVAILABLE FOR INSPECTION BY ANY REPRESENTATIVE

FORAFTER THE WORK IS COMPLETE.: 48 HOURS

75. FOR , THE OWNER OF THE HOT WORK OPERATION AR- EAS MUST BE

NOTIFIED IN WRITING BY THE CITYWIDE PERMIT HOLDER AT LEAST 48 HOURS BEFORE HOT

WORK IS TO BE STARTED.: CITYWIDE HOT WORK OPERATIONS

76. PRE-HOT WORK CHECKS MUST BE CONDUCTED BEFORE HOT WORK IS AUTHORIZED AND

AT LEAST .: ONCE PER DAY

77. FIRE WATCH WILL BE PROVIDED FOR A MINIMUM OF AFTER

WORK IS COMPLETE.: 30 MINUTES

78. HOT WORK AREAS MUST BE KEPT FEET AWAY FROM ANY

COMBUSTIBLE MATERIAL.: 35

79. PAPER, WOOD SHAVINGS, STRAW AND FABRIC ARE EXAMPLES OF

.: COMBUSTIBLE MATERIAL

80. THE ENTIRE WORK AREA SHOULD BE CHECKED AFTER COMPLETION OF HOT WORK FOR

.: FIRES

81. A MINIMUM RATING FIRE EXTINGUISHER MUST BE READILY

ACCESSIBLE.: 2-A:20-B:C

82. THE FIRE EXTINGUISHER MUST BE ACCESSIBLE WITHIN

FEET OF HOT WORK LOCATION AND FIRE GUARD.: 30

83. FOR TORCH-APPLIED ROOF SYSTEMS, A MINIMUM RAT-

ING FIRE EXTINGUISHER MUST BE READILY ACCESSIBLE.: 3-A: 40-B:C

84. PROTECTION SYSTEMS SHALL NOT BE SHUT OFF WHILE HOT WORK IS

PERFORMED.: AUTOMATIC SPRINKLER

85. COMPRESSED GAS CONTAINERS MUST BE REPLACED WHEN

.: THEY ARE EMPTY

86. EMPTY CONTAINERS MUST BE HANDLED IN THE SAME MANNER AS

.: FULL ONES

87. A MUST NOT BE ROLLED ON ITS SIDE OR ITS RIM.: COM- PRESSED GAS

CONTAINER

.: ONCE PER YEAR

100. Certificate of Fitness: fire watch for torch operations conducted at the following three

locations shall be conducted by at least one F-60 fire guard: 1- construction sites

2-in any building or structure, when the torch operation is conducted by a person holding a citywide permit

for torch operations

3-on any rooftop, or in connection with any torch-applied roofing system operation

101. Certificate of fitness holder must...: Keep the certificate of fitness upon his or her person, or

otherwise readily available for inspection by any representative of the department, at all times while conducting or supervising the material, operation or facility for which the certificate is required

102. The F-60 Certificate of Fitness holder is required to comply with the following FDNY cod

and rules section:: -Welding and other hot work -Fire prevention during welding, cutting and other hot work -liquefied petroleum gases -compressed natural gasses

103. FDNY permits 3 of the following: 1- storing, using or handling oxygen and a flammable gas, or

2- storing, using or handling any flammable gas in excess of 400 SCF or

3- storing, using or handling any oxidizing gas (ex. oxygen) in excess of 504 SCF

104. LPG - 400 SCF is how many pounds?: 47 lbs.

105. List of the number of LPG containers for storage, use, handling or transportation,

requiring a permit: 14.1 oz= 54 16.4 oz = 46 20 lbs = 3 33.5 lbs = 2 40 lbs = 2 100 lbs = 1

106. LPG: portable LPG containers that are more than 16.4 oz and CNG con- tainers with a capacity

greater than 8.7 SCF must NOT stored, handled, or used indoors/roof in the following occupancies.... -residential areas -factory and industrial occupancies -educational occupancies -institutional occupancies except as the commissioner may authorize by rule

107. Use of LPG/Propane on an occupied roof requires...: An affidavit from a licensed professional

(Architect or Engineer) stating the roof is constructed of non-combustible material(s)

-temporary are good anywhere from 1 day to 12 months depends on the construc- tion/operation needed

111. City-Wide Permit: -authorizes the permit holder to store, handle, use or sell hazardous materials, or

conduct an operation on a citywide basis

112. CityWide Permits are valid to temporarily store, handle, use, or sell haz- ardous materials or to

conduct an operation at one or more locations subject to the following restrictions:: -the duration of such activity at any individual location does not exceed 30 calendar days and all hazardous materials associated with such activity are removed from the location at the end of the workday. Periods of activity in excess of 30 calendar days at one location shall require a site-specific permit the quantity of hazardous materials being temporarily stored and used foes not exceed 5 gallons of gasoline, or 250 gallons of any other flammable liquid, and 300 gallons of any combustible liquid. Storage or use of hazardous materials in quantities exceeding these amounts requires a site-specific permit for each location at which such storage or use occurs

113. Transportation permit: -authorizes the permit holder to transport, pick up and deliver hazardous

materials. Any person who transports any hazardous mater- ial in the quantity of requiring a FDNY permit has to apply for a FDNY transportation permit. -The FDNY transportation permit sticker must be displayed on the vehicle

114. Permits: -not all are transferable

-any change in occupancy, operation, tenancy or ownership requires that a new permit be issued -The certificate of fitness holder is responsible for making sure that all fire safety regulations and procedures are obeyed on the premises

115. What should be readily available on the premise for inspection by fire department

representatives..?: Any and all permits

116. Hot work authorization (hot work program permit): -required for any pro- ject conducted on

premises involving hot work operations -not issued by FDNY -must be signed and issued by the responsible person and must be available for inspection by any representative of the fire department during the performance of the work and for 48 hours after the work is complete

  • this should not be issued unless the individuals conducting such operations are capable of performing such operations safely