1. FDNY G60 Fire Guard exam study materials 2. How to prepare for FDNY G60 Fire Guard test 3. FDNY G60 Fire Guard exam practice questions 4. FDNY G60 Fire Guard certification requirements 5. FDNY G60 Fire Guard exam passing score 6. FDNY G60 Fire Guard exam scheduling process 7. FDNY G60 Fire Guard exam retake policy 8. FDNY G60 Fire Guard exam locations in NYC 9. FDNY G60 Fire Guard exam fees and payment options 10. FDNY G60 Fire Guard exam duration and format 11. FDNY G60 Fire Guard exam topics and syllabus 12. FDNY G60 Fire Guard exam online registration 13. FDNY G60 Fire Guard exam preparation courses 14. FDNY G60 Fire Guard exam sample questions PDF 15. FDNY G60 Fire Guard exam study guide download 16. FDNY G60 Fire Guard exam tips and tricks 17. FDNY G60 Fire Guard exam renewal process 18. FDNY G60 Fire Guard exam for non-English speakers 19. FDNY G60 Fire Guard exam accommodations for disabilities

Typology: Exams

2024/2025

Available from 06/09/2025

stacey-studyguide
stacey-studyguide 🇺🇸

509 documents

1 / 10

Toggle sidebar

This page cannot be seen from the preview

Don't miss anything!

bg1
1 / 5
FDNYC G60 Fire Guard For Torch Operations
1. The fire watch for torch operations carried out in construction sites, in any building or structure,
or on any rooftop shall be conducted by at least F-60 fire guard ANS 1
2. True or False? The COF holder must keep the certificate upon his or her person at all times
while conducting the fire watch ANS True
3. Portable LPG containers that are more than
oz. must not be stored, handled, or used indoors or
on the roof in the following occupancies: resi- dential, factory, industrial, educational and
institutional ANS 16.4
4. Portable CNG containers that are more than SCF must not be stored,
handled, or used indoors or on the roof in the following occupancies: resi- dential, factory,
industrial, educational and institutional ANS 8.7
5. What do LPG containers hold ANS Liquefied petroleum gas.
6. What do CNG containers hold ANS Compressed natural gas.
7. Torch operations are considered a type of work ANS Hot.
pf3
pf4
pf5
pf8
pf9
pfa

Partial preview of the text

Download FDNYC G60 Fire Guard For Torch Operations and more Exams Safety and Fire Engineering in PDF only on Docsity!

FDNYC G60 Fire Guard For Torch Operations

1. The fire watch for torch operations carried out in construction sites, in any building or structure,

or on any rooftop shall be conducted by at least F-60 fire guard ANS 1

2. True or False? The COF holder must keep the certificate upon his or her person at all times

while conducting the fire watch ANS True

3. Portable LPG containers that are more than oz. must not be stored, handled, or used indoors or

on the roof in the following occupancies: resi- dential, factory, industrial, educational and institutional ANS 16.

4. Portable CNG containers that are more than SCF must not be stored,

handled, or used indoors or on the roof in the following occupancies: resi- dential, factory, industrial, educational and institutional ANS 8.

5. What do LPG containers hold ANS Liquefied petroleum gas.

6. What do CNG containers hold ANS Compressed natural gas.

7. Torch operations are considered a type of work ANS Hot.

8. Storing, using or handling any flammable gas, oxidizing gas, or oxygen and a flammable gas

requires an FDNY ANS Permit.

9. Use of liquefied petroleum gas (LPG) on an occupied roof requires an affidavit from a licensed

professional stating the roof is constructed of material ANS Non-combustible.

10. Any single liquefied petroleum gas (LPG) container must not exceed

lbs in weight ANS 100

11. Any single compressed natural gas (CNG) container must not exceed

standard cubic feet (SCF) ANS 381

12. What are the 3 types of FDNY permits for operations using liquefied petroleum gases (LPG),

compressed natural gas (CNG), or other flammable gas ANS (1) Site-specific.

(2) Citywide.

(3) Transportation.

13. What is a site-specific permit ANS It authorizes the storage, handling or use of flammable gases and

torch operations at a specific premises or location.

14. What are the 2 types of site-specific permits ANS (1) Permanent; valid for 12 months only.

21. A transportation permit must be displayed on the ANS Vehicle.

22. All permits shall be readily available on the premises for inspection by who ANS The FDNY.

23. What is a hot work program ANS A program implemented by the responsible person to oversee

hot work for the purpose of preventing fire.

24. What is a hot work program authorization ANS A document signed and issued by the responsible

person allowing hot work to be performed at the premises. It must be available for inspection by the FDNY during the work and for 48 hours after the work is completed.

25. What is hot work ANS Cutting, welding, brazing, soldering, grinding, thermal spraying, thawing

pipe, cadwelding, etc.

26. What is a hot work area ANS The area exposed to sparks, hot slag, radiant heat, or convective heat

as a result of hot work.

27. What is a fire guard ANS A COF holder trained to conduct a fire watch and perform fire safety

duties.

28. What is a fire watch ANS Temporary surveillance of a particular area for the purpose of detecting and

preventing fire hazards, raising alarms and notifying the FDNY.

29. What is hot work equipment ANS Electric or gas welding or cutting equipment used for hot work.

30. Who is the NFPA ANS National Fire Protection Association.

31. What is a responsible person ANS A person designated by the premises owner who is trained in hot

work safety and can authorize hot work performance.

32. What is a torch-applied roof system ANS Bituminous roofing systems using membranes that are

adhered by heating with a torch and melting asphalt back coating instead of mopping hot asphalt for adhesion.

33. What is the source of ignition in about 60% of all fires in industrial occupancies ANS

Sparks and hot metal.

34. For hot work operations with a citywide permit, the premises owner must be notified in writing

by the permit holder at least hours before hot work begins ANS 48

35. For all hot work operations, the premises owner must designate a .-

: Responsible person.

36. Hot work operations must be conducted under the general supervision of the ANS

Responsible person.

37. Before hot work is authorized and at least per day, the hot work area shall

be inspected for safety by the responsible person ANS Once.

38. Hot work inspection reports must be available at the premises for inspec- tion by the FDNY, and

for at least hours after hot work is complete ANS 48

39. What is the 35 feet rule ANS Hot work involving cutting or welding shall be conducted at least

35 feet from combustible materials.

43. Whenever the hot work area is accessible to persons other than the hot work operators, visible

hazard identification must be posted ANS Signs.

44. How many torches can be operated by an individual at one time ANS 1

45. Areas designed for hot work operations shall have floors with

surfaces ANS Non-combustible.

46. The use of a torch within a repair garage where a motor-fuel dispensing facility is situated

must be conducted within a enclosure ANS Fire-rated.

47. True or False? A fire watch must be maintained during any hot work operation ANS True

48. True or False? The person conducting a fire watch shall not have other duties ANS True

49. All hot work authorizations must be returned to the upon completion of

the work ANS Responsible person.

50. All original hot work authorizations must be filed with hot work

permit section ANS The FDNY.

51. At least one portable fire extinguisher with a minimum 2-A:20-B:C rating must be accessible

within feet of the location where hot work is per- formed ANS 30

52. There must be at least one portable fire extinguisher with a minimum 3-A 40-B:C rating for

operations utilizing heat-producing systems or other ignition sources ANS Roofing.

53. The difference between a fire watch and a fire guard is that not all individuals responsible to

maintain a fire watch must possess ANS An F- 60 COF.

54. At a construction site and torch-applied roofing system operation, every torch operator must

have ANS An F-60 COF holder performing a fire watch, unless the 2nd torch operation is not more than 50 feet away from the fire guard.

55. An additional F-60 fire guard is required to perform fire watch on the floor

if the torch operation is being conducted in a way that allows sparks and slag to travel there ANS Below.

56. How much longer after the conclusion of hot work must the fire watch continue his job ANS

30 minutes. This time may be extended depending on the possible hazards.

been ANS Shut off.

70. What should you do for a piped gas leak fire when it is not possible to shut off the gas supply

and the gas supply is limited ANS Allow the flame to burn itself out and call 911.

71. The COF holder should only consider extinguishing fires when they are

in size ANS Small.