FDNYC F60 Fireguard Test tested questions with revised correct answers a+ guarantee, Exams of Safety and Fire Engineering

1. FDNY G60 Fire Guard exam study materials 2. How to prepare for FDNY G60 Fire Guard test 3. FDNY G60 Fire Guard exam practice questions 4. FDNY G60 Fire Guard certification requirements 5. FDNY G60 Fire Guard exam passing score 6. FDNY G60 Fire Guard exam scheduling process 7. FDNY G60 Fire Guard exam retake policy 8. FDNY G60 Fire Guard exam locations in NYC 9. FDNY G60 Fire Guard exam fees and payment options 10. FDNY G60 Fire Guard exam duration and format 11. FDNY G60 Fire Guard exam topics and syllabus 12. FDNY G60 Fire Guard exam online registration 13. FDNY G60 Fire Guard exam preparation courses 14. FDNY G60 Fire Guard exam sample questions PDF 15. FDNY G60 Fire Guard exam study guide download 16. FDNY G60 Fire Guard exam tips and tricks 17. FDNY G60 Fire Guard exam renewal process 18. FDNY G60 Fire Guard exam for non-English speakers 19. FDNY G60 Fire Guard exam accommodations for disabilities

Typology: Exams

2024/2025

Available from 06/09/2025

stacey-studyguide
stacey-studyguide 🇺🇸

509 documents

1 / 12

Toggle sidebar

This page cannot be seen from the preview

Don't miss anything!

bg1
1 / 6
FDNYC F60 Fireguard Test Questions And Answers (Verified)
1. The Certificate of Fitness holder must keep the Certificates of Fitness upon his or her person,
or otherwise for inspection by
any representative of the Department, at all times while conducting or supervising the material,
operation or facility for which the certificate is required.
: Readily Available
2. Permits issued by the FDNY are required to conduct the following hot work
:: 1)Storing, Using or Handling Oxygen and a Flammable gas
2) LPG or CNG or Acetylene in excess of 400 SCF
3) Any oxidizing gas in excess of 504 SCF
3. Portable LPG containers that are more than must NOT be
stored, handled, or used indoors
: 16.4 oz
4. CNG containers with a capacity greater than must NOT
stored, handled, or used on the roof
: 8.7 SCF
pf3
pf4
pf5
pf8
pf9
pfa

Partial preview of the text

Download FDNYC F60 Fireguard Test tested questions with revised correct answers a+ guarantee and more Exams Safety and Fire Engineering in PDF only on Docsity!

FDNYC F60 Fireguard Test Questions And Answers (Verified)

1. The Certificate of Fitness holder must keep the Certificates of Fitness upon his or her person,

or otherwise for inspection by any representative of the Department, at all times while conducting or supervising the material, operation or facility for which the certificate is required. : Readily Available

2. Permits issued by the FDNY are required to conduct the following hot work

:: 1)Storing, Using or Handling Oxygen and a Flammable gas

2) LPG or CNG or Acetylene in excess of 400 SCF

3) Any oxidizing gas in excess of 504 SCF

3. Portable LPG containers that are more than must NOT be

stored, handled, or used indoors : 16.4 oz

4. CNG containers with a capacity greater than must NOT

stored, handled, or used on the roof : 8.7 SCF

5. Use of LPG/Propane on an occupied roof requires an

from licensed professional stating the roof is constructed of : Affidavit, Ar- chitect or Engineer, non-combustible materials

6. Any single standard portable LPG container must not exceed

in weight : 100 LBS

7. Any single CNG container must not exceed SCF

8. Such permit authorizes the permit holder to store, handle, or use flamma- ble gases, or conduct

a torch operation at a specific premises or location called ?: Site-specific permit

9. A may be a permanent permit or a tem- porary

permit. : Site-specific permit

13. Such permit is valid to temporarily store, handle, use or sell hazardous materials or to

conduct an operation at one or more locations is called?: - Citywide permit

14. Citywide permit the duration of such activity at any individual location does not exceed

days: 30 calendar

15. Periods of activity in excess 30 calendar days at any one location shall require a : Site-

specific permit

16. What should be readily available on the premise for inspection by Fire Department

representatives?: Any and all permits

17. Hot work program authorization is NOT issued by the FDNY, it must be signed and issued by

the : Responsible person

18. Hot work shall be available for inspection by any representative for

after the work is completed: 48 hours

19. For hot work operation with citywide permit, the owner of the premises of the hot work

operation areas must be notified in writing by the citywide permit holder at least the hot work is to be started: 48 hours before

20. Before hot work is authorized and at least while the

authorization is in effect, the hot work area shall be inspected by the respon- sible person: once per day

21. The pre-hot work check must be conducted by the be-

fore hot work is authorized and at least : responsible person, once per day

22. Hot work area must be kept feet away from any combustible materials

and combustible waste: 35 feet

23. All other hot work operations shall be conducted at least

feet away from any combustible materials and combustible waste: 25 feet

24. Sprinkler system protection while hot

work is performed.: must not be shut off or impaired

25. Gas Torch Operation Precautions: Each person must operate only one torch at a time and such

torch must not be left unattended while ignited

26. Protection of Combustibles: Areas designed for hot work operations shall have floors with

noncombustible surface

39. Torch Applied Roof-System: Bituminous roofing systems using membranes that are adhered by

heating with a torch and melting asphalt back coating instead of mopping hot asphalt for adhesion.

40. Under Time and Record keeping for any CNG or LPG torch operation timing, : the first

inspection shall be conducted 30 minutes after completion of torch operations; the second inspection 1 hour after completion of torch operations

41. The fire guards or fire watch personnel must complete a signed inspec- tion report (or the log

book). This report must be submitted to and retained by the person in charger of the torch operations. The log book should be : maintained on the premises for 48 hours after work is complete

42. Under Gas Welding and Cutting Precautions - The torch valves shall be closed and the gas

supply to the torch completely shut off when hot work operations are discontinues for a period of or more: 1 hour

43. Tests for suspected leaks in piping equipment and systems shall be made using : soapy water

44. Emergency notification: -fire guard can use wireless phone to make emer- gency notifications (make

sure that battery is charged to last the entire shift)-noti- fying FDNY by phone is the most direct and effective way to make notification of an emergency

45. Fire Detection System: fire watch for impairment must be provided when the alarm system is offline

46. A portable fire extinguisher with at least 2-A:20--B:C rating...: must be readily accessible within

30 feet of the location where hot work is performed and where the fire guards are positioned -in case of fire, 911 must be called

47. In event of a fire extinguisher has been discharged...: a fully charged replace meant is

required before work can resume

48. Portable fire extinguishers are important in?: -preventing a small fire from growing into a larger

one -not intended to fight large or spreading fire

49. The C of F holder should only consider extinguishing a fire when?: they are limited in size and

spread such that they can be readily extinguished using a portable fire extinguisher

50. P.A.S.S.: Pull, Aim, Squeeze, Sweep

51. All fire extinguishers installed so that?: the top of the extinguisher is not more than 5 ft above the

floor and the clearance between the bottom of the extinguisher and the floor is less than 4in.-in other

52. Where to point the extinguisher to extinguish a fire...: the dry chemical stream must be

directed toward the point where the flame begins

  • DO NOT direct the chemical stream at the center of the flame, this will not extinguish the fire

53. Extinguishing a gas fire caused by a leak...: -easiest way to extinguish this fire is to shut off by

using the emergency shut off valve until the flame is extinguished

54. Extinguished piped gas: -for piped gas, the gas supply must be shut off first then call 911

-never attempt to extinguish the flame unless the gas supply is shut -when not possible to shut off the gas supply (e.g. the fire is near the control valve or the shut-off valve) and the gas supply is limited (e.g. it is from a cylinder) allow the flame to burn itself out and call 911-in meantime, prevent fire spreading to the surrounding materials

55. Class A fire: -Fires caused by ordinary combustibles such as wood, paper, cloth, and plastic fires

-to extinguish a class A fire, these extinguishers utilize either the heat -absorbing effects of water or the coating effects of certain dry chemicals

56. Class B Fire: -fires are caused by flammable or combustible liquids and gases such as oil, gasoline,

etc. -to extinguish..the blanket-smothering effect of oxygen excluding media such as CO2, dry chemical or foam is most effective

57. Class C Fire: -fires that involve electrical equipment-these fires must be fought with extinguishers that

do not conduct electricity -foam and water type extinguishers must not be used to extinguish electrical fires -after shutting off the electrical equipment, extinguishers for Class A or B fires may be used

58. Class D Fire: -fires caused by ignitable metals, such as magnesium, titanium, and metallic sodium, or

metals that are combustible under certain conditions, such as calcium, zinc, and aluminum -generally, water should not be used to extinguish these fires

59. Fire extinguisher inspections: -must be done monthly

-owner of premises is responsible to designate a person to perform a monthly inspection -"quick check"

60. CNG: compressed natural gas