Fire Safety and Evacuation Procedures in Places of Assembly, Exams of Safety and Fire Engineering

A comprehensive overview of fire safety and evacuation procedures specifically designed for places of assembly. it details the roles and responsibilities of fire safety personnel, including pre-event inspections, emergency response protocols, and the importance of maintaining safe building conditions. The document also includes practical exercises and questions to test understanding of key concepts.

Typology: Exams

2024/2025

Available from 05/13/2025

mohh-wise
mohh-wise 🇺🇸

461 documents

1 / 15

Toggle sidebar

This page cannot be seen from the preview

Don't miss anything!

bg1
F-03 Fireguard-Answered-A+ Rated 2023
Place of assembly safety personnel
The name of the Certificate of Fitness that will be issued by the Fire Department to
those applicants that pass the exam is
Fire guards
In the past, the Fire Department has commonly referred to these type of individuals
as
manage the occupants in the event of a fire or other emergency
Place of asssmebly safety personnel are needed in certain in indoor and outdoor
places of assembly and public gatherings places primarily to
Occupants must know not only
where exits are, but also when and how to use them
moving them away from the hazard
The management of occupants is primarily involved with
a fire safety and evacuation plan that provides for the safety of building occupants
in the
event of fire or other emergency
Most assembly occupancies are required to have
pf3
pf4
pf5
pf8
pf9
pfa
pfd
pfe
pff

Partial preview of the text

Download Fire Safety and Evacuation Procedures in Places of Assembly and more Exams Safety and Fire Engineering in PDF only on Docsity!

F-03 Fireguard-Answered-A+ Rated 2023

Place of assembly safety personnel The name of the Certificate of Fitness that will be issued by the Fire Department to those applicants that pass the exam is Fire guards In the past, the Fire Department has commonly referred to these type of individuals as manage the occupants in the event of a fire or other emergency Place of asssmebly safety personnel are needed in certain in indoor and outdoor places of assembly and public gatherings places primarily to Occupants must know not only where exits are, but also when and how to use them moving them away from the hazard The management of occupants is primarily involved with a fire safety and evacuation plan that provides for the safety of building occupants in the event of fire or other emergency Most assembly occupancies are required to have

The number and capabilities of building occupants, the type, the location and arrangement of building exits; the fire and it's effects on the people and the building and the number The plan must consider interfere with the occupants ability to discern the path of egress travel. Lighting conditions in assembly spaces may 75 or more members may gather indoor or 200 or more may gather outdoors FDNY may require at least one place of assembly safety personnel in the premises where the certificate of occupancy indicates the number of the number of minimum safety personnel will be indicated in the TPA permit For the temporary place of assembly situations 1 hour prior to the events and stay until all audience members leave For the TPA events, the safety personnel are recommended to arrive at the premises at least keep the Certifiacte of Fitness The certificate of fitness holder must __________ upon his or her person, or otherwise readily available for inspection by any representative of the Department FSP Staff The individuals identified in a fire safety and evacuation plan as responsible for the implemenation of such plan

To be an effective place of assembly safety personnel, it is recommended that____________ orientation. Building owner. The personnel should be provided with an___________ from the the fire safety director/fire safety coordinator,___________ or other on-site personnel familiar with and responsible for the fire safety and evacuation plan before starting to perform their duties.

  1. All physical features are installed or arranged according to the approved place of assembly drawing
  2. Door hardware and physical components of the means of egress must be maintained in good working order at all times
  3. All requires means of egress and access to such including each exit, exit access and exit discharge, must be maintained free from obstructions and impediments to immediate use in the event of fire or other emergency.
  4. No storage of combustible material and combustible waste in corridors
  5. Maximum capacity posted (placecard required)
  6. Emergency exit lighting
  7. Exit signs and signs indicating the location of accessible means of egress are posted
  1. the seats should be securely fastened to the floors.
  2. A functioning fire alarm and sprinkler system, if available. If any defects are discovered, the building owner or the designated responsible person should be aware of it and should then make arrangements to have the defects corrected. The following safety requirements should be met: additional F-01 fire guard(s) If any required fire protection system is out of service, ___________ is/are required. Exits Storage Capacity Asisles Protection Emergency The acronym ESCAPE may be used as a reminder for doing the pre-event inspection: performing arts, motion picture theaters or other similar indoor public gatherings Safety personnel are required for __________ conduct the daily inspections The responsible person must ______________ in a performing arts or motion picture theater on any day on which the occupant is to be used and occupied for a performance or other audience event 1.Means of egress including exit access, exits and exit discharges, shall be inspected daily to ensure that they are unobstructed 2.Automatic fire doors shall be inspected to ensure that there are no obstructions to

All areas of the theater, including the ____________ near the fresh air intakes for the buildings ventilation system, shall be inspected Manual fire alarm boxes. the central station ___________ locates on the stage of performing arts theaters shall be _____________. Prior notification shall be made to _______________ monitoring the fire alarm system. event coordinator, 10 minutes, location of the exits During the performance, the ____________ should make an audio announcement not more than ______________ to the start of each performance or program informing the occupants of the _____________ to be used in case of an emergency commissioner The ______________ may grant an exception if the occupancy has at least one exit clearly visible from every seat or standing area

  1. The prohibition against smoking in performing arts, motion picture theaters or other similar indoor public gatherings.
  2. All proscenium wall doors in a performing art theater are kept closed
  3. Aisles must be unobstructed During the performance, as a place of assembly safety personnel, you should verify if the following requirements are complied with:

rope, tape, barriers, barricades, fencing or other suitable materials at a height of not less than 3 feet nor more than 4 feet above the floor The space to be occupied by standing audience members must be separated from the space to be left clear for passage by a__________ durable markings on the floor Standing areas must be clearly demarcated by _________ indicating he boundaries of the standing area. one row of persons For standing in balconies, only____________ shall be allowed to stand in balconies 6 feet, 16 feet deep, 6 feet, four rows If the passageway is more than ________ and less than ________, persons may stand therein, provided an unobstructed passageway of at least _______ in depth is left open, and there are no more than ________ of persons standing. 16 feet, 10 feet If the passageway is more than __________, any number of persons or rows of persons may stand therein, provided that an unobstructed passageway of at least _______ in depth is left open 6 feet or less in depth, two rows

  1. the limitation of the number of occupants 4.the concessionaires and the nature of the activity they will conduct and the associate risks
  2. the locations of fire extinguishers 6.if there is a dedicated telephone line to the fire department shall be available for an emergency As a safety personnel, you should know two way radio every safety personnel should be equipped with an____________ at every exit scanner, hand held counter every safety personnel should be equipped with________ at every entrance your supervisor or other responsible person The pre event inspections should be conducted by__________ before the area is used or occupied Compressed Natural Gas The storage, handling and use of ___________ are prohibited at outdoor public gatherings
  3. Prevent overcrowding by monitoring the amount of people in your area of assembly
  4. Monitor the areas and confirm that the exit paths are always staying clear.
  1. you should look for situations that could lead to challenges in the event of emergency During the event, as safety personnel, you should_____ unobstructed, not be allowed Required aisles must be__________. People should _____________ to stand, in or at the head of an aisle telephone call After manual pull station has been used, a __________ must always be made to 911 or the Fire Department dispatcher the exits Fire alarm pull stations shall be located near __________ most effective way Activating the pull station is the ______________to notifythe building occupants in case of a fire emergency Approved plastic covers _____________ are permitted to protect fire alarm manual pull stations and provide relief from false alarms Single action and double action Two types of fire alarm pull stations are indoors, office buildings

standpipe and sprinkler systems can provide automatic or manual sprinklers as well as connection points for ____________ that they are always filled with water Wet systems are charged meaning ________ hospitals, universities The fire alarm systems are required in the following buildings___________ automatic, manual or borh A fire alarm system is classified as phone Notifying by _______ is the most direct and effective way to notify the Fire Departmemt pull station Activating the ________ is the most effective way to notify the building occupants in case of a fire emergency a flashlight, two way radio and cell phone The FDNY highly recommends that you should be equipped with ________ be calm and move quickly to the nearest exit in an orderly manner During an emergency, occupants must be instructed to _________ the designated person In the case of injury or some other medical emergency, inform__________

emergency health care facility With the attendance of over 5,000 people, an on site ___________ may he provided call 911 and also follow the medical emergency reporting protocols If there is no on site emergency health care facility, the safety personnnel should_________ Avoid, Run, Barricade If an active shooter incident occurs inside the building, three tactics should be followed wood paper Class A Fires are caused by flammable liquid Class B fires are cause by electrical equipment Class C fires are caused by metals Class D fires are caused by kitchen oils Class K fires are causes by what kind of fires the extinfuishers may be used on