Experimental analysis of a flat plate solar collector with integrated latent heat thermal storage
Typology: Essays (university)
1 / 6
This page cannot be seen from the preview
Don't miss anything!
2017 , Volume 1 , Number 3 , pages 7 – 12
(^1) Mechanical Engineering Department, Universidad del Norte, Colombia (^2) Faculty of Mechanical and Industrial Engineering, Universidad Pontificia Bolivariana, Colombia (^3) Mechanical Engineering Department, Universidad de Córdoba, Colombia (^1) E mail: mycarmona@uninorte.edu.co , 2 E mail: mario.palaciov@upb.edu.co
https://doi.org/10.25034/ijcua.2018.36zd www.ijcua.com Copyright © 2017 Contemporary Urban Affairs. All rights reserved.
1. Introduction Solar energy is the most widely available energy source in the world. However, it presents some obstacles to its implementation such as sensitivity to climatic conditions and intermittency. Therefore, it is necessary to develop technologies that allow storing solar energy for the periods in which it is not available, or its power is low. Two common methods of storing solar thermal energy are sensible and latent heat storage. While sensible heat is more common in practical applications, latent heat storage provides higher storage density, with narrow temperature variation. (Abhat, 1983) reported one of the earliest reviews on latent heat thermal storage. (Zalba et al. , 2003) reviewed thermal
Article history: Received 2 August 2017 Accepted 10 August 2017 Available online 12 October 2017 Keywords: Solar collector; Thermal storage; Latent heat storage.
energy storage with PCM and its heat transfer analysis and applications. (Farid et al. , 2004; Kenisarin and Mahkamov, 2007; Nkwetta and Haghighat, 2014; Sharma et al., 2009) reviewed solar energy storage using phase change materials. (Chandel and Agarwal, 2017) Reviewed the current state of research on energy storage, toxicity, health hazards and commercialization of phase changing materials. (Pandey and Chaurasiya, 2017) reviewed the analysis and development of solar flat plate collectors. Although numerous works on latent heat storage, no commercial solar heaters with built- in PCM storage have been reported. However, preliminary studies in laboratory prototypes have shown considerable increases in efficiency and supply capacity. (Kürklü et al., 2002) found a large difference between ambient temperature and water temperature both at day and at night. With the experimental techniques used, it was not possible to determine the phase change point at least in a general approach. No performance comparison is made against traditional devices. However they showed that its prototype has advantages in manufacturing cost and total weight for commercial devices, although it does not include an energy analysis. In countries with tropical climates, no scientific references have been found in studies of this kind of technology, in spite of the great capacity of available solar energy, quite possibly due to the lack of suitable commercial PCMs for this application. (Mehling et al., 2003) presented experimental results and numerical simulation of a water tank with a PCM module using an explicit finite-difference method. Experiments and simulations indicated an increase in energy density of the tank of 20% to 45%. (Canbazoglu et al ., 2005) Analyzed experimentally the time variations of the water temperatures at the midpoint of the heat storage tank of a solar heating system with sodium thiosulfate pentahydrate as PCM. It was obtained an increase in the produced hot water mass and total heat accumulated approximately 2.59– 3.45 times of the conventional solar water- heating system. (Cabeza et al., 2006) constructed an experimental solar pilot plant to test the PCM behavior in real conditions. It was obtained a discharge temperature stabilization near to 54 1C for a period of time between 10 and 12 h. (Mettawee and Assassa, 2006) performed parametric studies of different operating conditions, concluding that as the material melts, the heat transfer by convection increases the speed of the accumulation process. (Koca et al., 2008) performed an analysis of energy and exergy a latent heat storage system with phase change material (PCM) for a flat-plate solar collector. The obtained experimental data showed that exergy efficiencies of latent heat storage systems with PCM are very low. However, the area of collector surface was smaller than that of the PCM surface area. As a result of this, the cost of the latent heat storage system was high and outlet temperature obtained was low. (Bouadila et al., 2014) have developed an experimental study on a solar flat plate water heater with an accumulation of thermal energy in the collector using a PCM. Experimental measurements ascertain that the outlet temperature was not affected by the severe global solar radiation fluctuations. The solar collector remains a uniform useful heat around 400W during 5 h after sunset. (Serale et al., 2014) present an approach to increase the performance of flat collectors based on the exploitation of the latent heat of the heat carrier fluid. The aim of this paper is to analyze experimentally the performance of a lab-scale solar collector built with commercial features and a latent heat storage unit inside it.
2. Method and materials It was designed and constructed a flat plate solar collector prototype with a cavity to place macro-encapsulated PCM under the absorber plate. A schematic representation of the prototype is shown in Fig. 1. Further details of the collector are presented in Fig. 2 and described in Table 1. The PCM was microencapsulated in 4 rectangular steel containers of 4000 X 4000 X 30 mm. Each container was filled with 3.35 kg of semi refined paraffin wax with a nominal melting point between 58-60 °C. Figure 1. Schematic representation of the Solar Collector.
with high radiation the highest efficiency values were obtained during medium radiation values. Figure 2. Experimental results by day. Table 2. Results of the tests and weather conditions. Exp. Campaign Days in Figure X Weather Average Acc.rad [kWh/day] Rad. Std. dev [kWh/day] Average Efficiency [%] Oct 01 - 20 Rainy 4.45 1.33 20. Dec 21 - 40 Scattered 5.22 0.41 27. Feb 41 - 60 Clear 6.16 0.51 24. Total - 5.27 1.10 24. The following graphs present the behavior of the collector on March 12, 2017. Figure 3 and Figure 4 shows respectively the solar radiation and wind speed measured by the weather station. This day has a high incidence of solar radiation with an accumulated radiation of 5.27 kWh. Figure 5 shows that the outlet temperature did not decrease too much during the cloudiness events of 11:00 and 15:00 which shows that the thermal energy storage system provides stability to the water supply. Figure 3. Solar radiation Figure 4. Wind speed 0 5 10 15 20 25 30 35 40 0 1 2 3 4 5 6 7 8 0 10 20 30 40 50 60 Efficiency [%] Accumulated Energy [kWh/day] Day Acumulated radiation Useful Heat Efficiency day 0 200 400 600 800 1000 1200 Solar radiation [W/m^2] 6 8 10 12 14 16 18 20 22 24 Time [H] 0 1 2 3 4 5 0 2 4 6 8 10 12 14 16 18 20 22 24 Wind Speed [m/s] Time [H]
Figure 5. Temperatures of absorber plate, water inlet, and water outlet Figure 6. PCM Temperature and ambient temperature Figure 7. Temperature of air gap and glass cover Figure 8. Useful Heat. It can be observed in Figure 6 that the PCM containers store heat energy by sensible heat until 14:00, from where the temperature at container’s top (T.PCMU) remains at 60°C until 16:00, indicating storage by latent heat. However, it should be noted in Figure 5 that the temperature of the absorber plate reaches the melting point of the PCM only for 2 hours, in many experimental tests the phase change temperature is never reached. This gives a short time to the PCM to accumulate energy by latent heat resulting in a PCM discharging process at a non-constant temperature. On the other hand, it can be seen in Figure 6 an asymmetric charge/discharge process. Despite the proper charging process during the morning the storage system was unable to provide thermal energy to the working fluid after 18:00 as can be seen in Figure 8 This may be due to an excess of PCM in the solar collector. In fact, Figure 6 shows that, although the upper part of the PCM reaches the phase change temperature, the lower part never reaches it and even its maximum temperature is reached about 2 hours later. Therefore, it can be inferred that during the night the molten PCM transfers heat to the solid PCM layers instead of the working fluid.
4. Conclusions In this paper, an experimental analysis was carried out to evaluate the performance of a flat plate solar collector with integrated microencapsulated PCM as latent heat storage system. The highest efficiency of the prototype was obtained at accumulated radiation of 5. kWh/day. Values above or below this amount of radiation resulted in lower efficiency values. Asymmetric PCM charge/discharge process was observed. Therefore, reduce the PCM mass is recommended to avoid upper layers discharge thermal energy to lower layers instead of the absorber plate. It was obtained that the PCM modules provided stability to the outlet temperature against strong fluctuations in solar radiation. However, it was unable to supply thermal energy to the working fluid during the night. The short time the absorber plate reached the melting point of the PCM may be a cause of this. Thus, experimental analysis and simulation with PCM with lower phase change temperature is recommended. Acknowledgments This investigation has been partially funded by the Colombian Administrative Department of Science, Technology, and Innovation- COLCIENCIAS, through the program “es Tiempo 0 10 20 30 40 50 60 70 6 8 10 12 14 16 18 20 22 24 Temperature [C] Time [H] T.in T.out T.plate 0 10 20 30 40 50 60 70 6 8 10 12 14 16 18 20 22 24 Temperature [C] Time [H] T.PCMU T.PCML T.amb 0 10 20 30 40 50 60 70 6 8 10 12 14 16 18 20 22 24 Temperature [C] Time [H] T.air T.glass 0 50 100 150 200 250 6 8 10 12 14 16 18 20 22 24 Heat flux [W] Time [H]