Docsity
Docsity

Prepare for your exams
Prepare for your exams

Study with the several resources on Docsity


Earn points to download
Earn points to download

Earn points by helping other students or get them with a premium plan


Guidelines and tips
Guidelines and tips

Electric Heat ESCO - HVAC Excellence Exam Questions & 100% Verified Answers 2025/2026, Exams of Refrigeration and Air Conditioning

Electric Heat ESCO - HVAC Excellence Exam Questions & 100% Verified Answers | Latest Update | Already Graded A+

Typology: Exams

2024/2025

Available from 02/23/2025

tizian-kylan
tizian-kylan ๐Ÿ‡บ๐Ÿ‡ธ

2.7

(21)

3.8K documents

1 / 17

Toggle sidebar

This page cannot be seen from the preview

Don't miss anything!

bg1
1 | P a g e
Electric Heat ESCO - HVAC Excellence Exam
Questions & 100% Verified Answers | Latest
Update | Already Graded A+
Before working on an electric furnace the tech should
๐Ÿ—ธ๐Ÿ—ธ๐Ÿ—ธ: Review diagram, remove jewelry, and follow safety procedures. ALL OF THE
ABOVE.
A GFCI circuit breaker
๐Ÿ—ธ๐Ÿ—ธ๐Ÿ—ธ: detects current leaks to groound
the conductor in an electric heat element is usually made of
๐Ÿ—ธ๐Ÿ—ธ๐Ÿ—ธ: Nichrome
An example of resistive load is
๐Ÿ—ธ๐Ÿ—ธ๐Ÿ—ธ: crankcase heater
an example of an inductive load is
๐Ÿ—ธ๐Ÿ—ธ๐Ÿ—ธ: motor
pf3
pf4
pf5
pf8
pf9
pfa
pfd
pfe
pff

Partial preview of the text

Download Electric Heat ESCO - HVAC Excellence Exam Questions & 100% Verified Answers 2025/2026 and more Exams Refrigeration and Air Conditioning in PDF only on Docsity!

Electric Heat ESCO - HVAC Excellence Exam

Questions & 100% Verified Answers | Latest

Update | Already Graded A+

Before working on an electric furnace the tech should ๐Ÿ—ธ๐Ÿ—ธ๐Ÿ—ธ : Review diagram, remove jewelry, and follow safety procedures. ALL OF THE ABOVE. A GFCI circuit breaker ๐Ÿ—ธ๐Ÿ—ธ๐Ÿ—ธ : detects current leaks to groound the conductor in an electric heat element is usually made of ๐Ÿ—ธ๐Ÿ—ธ๐Ÿ—ธ : Nichrome An example of resistive load is ๐Ÿ—ธ๐Ÿ—ธ๐Ÿ—ธ : crankcase heater an example of an inductive load is ๐Ÿ—ธ๐Ÿ—ธ๐Ÿ—ธ : motor

an electric furnace is marked 208/230 single phase 60Hz A tech reads 200 vac at the power supply and determines ๐Ÿ—ธ๐Ÿ—ธ๐Ÿ—ธ : the voltage is too low voltage imbalance between any leg of 3 phase power supply may not exceed ๐Ÿ—ธ๐Ÿ—ธ๐Ÿ—ธ : 2% the limit switch on an electric furnace is a ๐Ÿ—ธ๐Ÿ—ธ๐Ÿ—ธ : Automatic reset switch the sequencer timers on electric heater will usually energize the 1st heating element after a time delay of ๐Ÿ—ธ๐Ÿ—ธ๐Ÿ—ธ : 1 to 30 sec the amount of btus produced by 1 watt of electricity is ๐Ÿ—ธ๐Ÿ—ธ๐Ÿ—ธ : 3.413 btus a tech reads 60 amps with a clamp on amp meter on a forced air furnace. the supply voltage is 230 volts AC, approx how many watts is the furnace using ๐Ÿ—ธ๐Ÿ—ธ๐Ÿ—ธ : 13, a furnace is using 15,500 watts approx Kw

the control that prevents duct heater from operating unless there is adequate supply air is ๐Ÿ—ธ๐Ÿ—ธ๐Ÿ—ธ : fan interlock the COP for electric resistance heat is ๐Ÿ—ธ๐Ÿ—ธ๐Ÿ—ธ : 1 to 1 what is the maximum kW element used on each contact of a residential heat sequencer ๐Ÿ—ธ๐Ÿ—ธ๐Ÿ—ธ : 5 kW electric heaters are generally rated at ____ volts ac for kW output ๐Ÿ—ธ๐Ÿ—ธ๐Ÿ—ธ : 240 the first stage of a sequencer usually has a set of contacts to ๐Ÿ—ธ๐Ÿ—ธ๐Ÿ—ธ : start the blower fan motor an automatic reset safety on a heater element generally opens at ____*F ๐Ÿ—ธ๐Ÿ—ธ๐Ÿ—ธ : 130 - 190 *F most heating elements are mounted on which type of insulator ๐Ÿ—ธ๐Ÿ—ธ๐Ÿ—ธ : mica or ceramic

a 10 kW electric heater operating at 240 v draws 42 amps, what will a 10 kW heater wired to 480 volts draw ๐Ÿ—ธ๐Ÿ—ธ๐Ÿ—ธ : 21 amps the purpose of a sequencer is to ๐Ÿ—ธ๐Ÿ—ธ๐Ÿ—ธ : avoid a sudden power load two major factors in determining the temp rise of an electric furnace are ๐Ÿ—ธ๐Ÿ—ธ๐Ÿ—ธ : furnace KW and CFM a major cause of electrical heat element burn out ๐Ÿ—ธ๐Ÿ—ธ๐Ÿ—ธ : low airflow a tech is checking the resistance on delta wired 3 phase 240 v 15 kW electic duct heater if one element is open he would read ๐Ÿ—ธ๐Ÿ—ธ๐Ÿ—ธ : L 1 to L 2 22 Ohm L 1 to L 3 22 ohm L 2 to L 3 infinity the purpose of setting a heat anticipator properly is to ๐Ÿ—ธ๐Ÿ—ธ๐Ÿ—ธ : control cycling time a 10 kW heater installed in a 2 ton central air conditioning heating furnace should have an air flow of _____ CFM

A tech is checking the output of a 5 kW supplemental heater used with a heat pump. The heating element is controlled by what stage of the thermostat ๐Ÿ—ธ๐Ÿ—ธ๐Ÿ—ธ : Auxiliary heating To measure supply grill air speed, the tech should use an ๐Ÿ—ธ๐Ÿ—ธ๐Ÿ—ธ : anemometer when installing a rooftop heating and cooling unit, to prevent condensate pan problems you should ๐Ÿ—ธ๐Ÿ—ธ๐Ÿ—ธ : trap the drain line the contact points of a sequencer on a live heater may be checked by using this meter ๐Ÿ—ธ๐Ÿ—ธ๐Ÿ—ธ : voltmeter when removing any high voltage component for safety the tech should ๐Ÿ—ธ๐Ÿ—ธ๐Ÿ—ธ : lock out/tag out power panel the best method to install a flexible duct to a metal collar is to ๐Ÿ—ธ๐Ÿ—ธ๐Ÿ—ธ : tie wrap and mastic the inner and outer liners

most residential AC and electric heating system will have a fan system rated for a maxium total pressure loss of ๐Ÿ—ธ๐Ÿ—ธ๐Ÿ—ธ : 0.40 - 0.50 WC (inches of water column) to adjust the airflow on a heater with a belt driven blower you should ๐Ÿ—ธ๐Ÿ—ธ๐Ÿ—ธ : adjust the motor pulley the driven belt width used on fractional HP motor is ๐Ÿ—ธ๐Ÿ—ธ๐Ÿ—ธ : A typical RPM of residential direct driven blower is ๐Ÿ—ธ๐Ÿ—ธ๐Ÿ—ธ : 1000 - 1200 RPM turning vanes are added to sheet metal elbows to ๐Ÿ—ธ๐Ÿ—ธ๐Ÿ—ธ : increase air velocity the maximum recommended return air velocity of a residential filter ๐Ÿ—ธ๐Ÿ—ธ๐Ÿ—ธ : 400 fpm a rigid residential duct system should be desgined for a maxium trunk velocity of ____ FPM ๐Ÿ—ธ๐Ÿ—ธ๐Ÿ—ธ : 700 - 1,

๐Ÿ—ธ๐Ÿ—ธ๐Ÿ—ธ : 15 to 25 amps a tech checks a fan motor run capacitor to ground with an analog ohmeter what resistance scale should be used ๐Ÿ—ธ๐Ÿ—ธ๐Ÿ—ธ : r X 10 K a tech is checking the ressitance of a multi speed blower motor the reading are high to common 10 med to common 12 low to common 14 start to common infinity these reading indicate ๐Ÿ—ธ๐Ÿ—ธ๐Ÿ—ธ : the motor has an open start winding the heating elements in a single phase 15 kW heater are usually wired in ๐Ÿ—ธ๐Ÿ—ธ๐Ÿ—ธ : parallel this type of switch is used to detect supply airflow ๐Ÿ—ธ๐Ÿ—ธ๐Ÿ—ธ : pressure differential the contact points on a de-energized heater relay are checked by using this meter ๐Ÿ—ธ๐Ÿ—ธ๐Ÿ—ธ : ohmeter

a multi speed PSC motor has a start winding and ๐Ÿ—ธ๐Ÿ—ธ๐Ÿ—ธ : a run capacitor a grounding strap must always be used with this motor mount ๐Ÿ—ธ๐Ÿ—ธ๐Ÿ—ธ : resilient motor the best description of a fuse link safety is ๐Ÿ—ธ๐Ÿ—ธ๐Ÿ—ธ : a one time device a megger meter is used to check motors for ๐Ÿ—ธ๐Ÿ—ธ๐Ÿ—ธ : winding insulation quality a tech takes the temp rise of an electric furnace what is being measured ๐Ÿ—ธ๐Ÿ—ธ๐Ÿ—ธ : sensible heat only a typical electronic air cleaner will trap ____ % of air particulates ๐Ÿ—ธ๐Ÿ—ธ๐Ÿ—ธ : 95 - 100% which one of the following filters will create the highest static pressure drop ๐Ÿ—ธ๐Ÿ—ธ๐Ÿ—ธ : pleated fiberglass

๐Ÿ—ธ๐Ÿ—ธ๐Ÿ—ธ : glass enclosed what type of safety is recommended for use with baseboard electric heat ๐Ÿ—ธ๐Ÿ—ธ๐Ÿ—ธ : limit switch to determine the proper heat anticipator setting ๐Ÿ—ธ๐Ÿ—ธ๐Ÿ—ธ : measure the total current in the 24v circuit that passes through the thermostat control bulb and heat anticipator duct heatesr are used generally for ๐Ÿ—ธ๐Ÿ—ธ๐Ÿ—ธ : auxiliary heaters a tech is using an extension ladder to work on roof top unit the top of the ladder should extend ____ beyond the support point ๐Ÿ—ธ๐Ÿ—ธ๐Ÿ—ธ : 3 feet a good description of how a sequencer operates the blower motor on an electric furnace is ๐Ÿ—ธ๐Ÿ—ธ๐Ÿ—ธ : time on - time off a BTU is the amount of heat required to raise the temp of one pound of water ๐Ÿ—ธ๐Ÿ—ธ๐Ÿ—ธ : one degree F

an installed furnace should have a minimum of ____ inches for service access ๐Ÿ—ธ๐Ÿ—ธ๐Ÿ—ธ : 30 what instrument would a tech use to calculate return airflow to a furnace ๐Ÿ—ธ๐Ÿ—ธ๐Ÿ—ธ : velometer the auxiliary terminals on an electric sequencer is normally rated at ๐Ÿ—ธ๐Ÿ—ธ๐Ÿ—ธ : 24 v. 5 amps you are installing 2 sections of a rectangular sheet metal duct to main supply line what connectors are used to secure sections of the trunk line ๐Ÿ—ธ๐Ÿ—ธ๐Ÿ—ธ : S connectors and drive clips metal ductwork tends to transmit noise and fan vibrations to conditioned spaces in residential installations. what types of connectors are specified to control this ๐Ÿ—ธ๐Ÿ—ธ๐Ÿ—ธ : flex connectors fiberglass duct wrap is used to insulate round metal ducts. what is the apporx R - value for 1 inch of this insulation ๐Ÿ—ธ๐Ÿ—ธ๐Ÿ—ธ : between r- 3 & 4

a furnace blower motor is rated at 230 v what would be in the allowable voltages variance ๐Ÿ—ธ๐Ÿ—ธ๐Ÿ—ธ : +- 10% the first stage of the most electric heat sequencers in residential furnace turns on the_____ ๐Ÿ—ธ๐Ÿ—ธ๐Ÿ—ธ : 1 st stage elements or blower and the 1 st stage elements the formula (x = sensible heat BTU/h / (1.08 X TD) ๐Ÿ—ธ๐Ÿ—ธ๐Ÿ—ธ : CFM A tech needs to run thermostat wire 90 ft. to keep voltage drop at a minimum the tech should use ๐Ÿ—ธ๐Ÿ—ธ๐Ÿ—ธ : 16 AWG When measuring the temperature split for an electronic furnace, make sure the temperature probe is not what? ๐Ÿ—ธ๐Ÿ—ธ๐Ÿ—ธ : affected by radiant heat Which type of heat will make items in a room warm to the touch? ๐Ÿ—ธ๐Ÿ—ธ๐Ÿ—ธ : Radiant heating panels

How many amps are used for each 5 kW of heat? ๐Ÿ—ธ๐Ÿ—ธ๐Ÿ—ธ : 15 Amps Which of the following is used in heating doorways, inside, or outside work areas? ๐Ÿ—ธ๐Ÿ—ธ๐Ÿ—ธ : Radiant spot heating