California UST Service Technician Exam with Questions and Answers, Exams of Public Choice

California UST Service Technician Exam with Questions and Answers By December 22, 1998, all automatic line leak detectors installed on single-walled pressurized piping must be capable of: ANSWER✓✓ shutting down the pumping system An automatic tank gauge is capable of ________. ANSWER✓✓ Measuring diesel product temperature; Activating low level alarms for premium grade gasoline; Measuring product level of diesel product; When an automatic tank gauge is utilized for single-walled tank leak detection, it shall test the tank at least monthly after product delivery or when the tank is filled to within _____ percent of the highest operating level during the previous month. ANSWER✓✓ 10 When an automatic tank gauge is utilized for single-walled tank leak detection, it shall generate a post-test hard copy data report of the following information EXCEPT: ANSWER✓✓ outside air temperature Approved cathodic protection methodologies include: ANSWER✓✓ sacrificial anodes; impressed current

Typology: Exams

2024/2025

Available from 02/17/2025

school-inspector
school-inspector 🇺🇸

2

(1)

4.5K documents

1 / 15

Toggle sidebar

This page cannot be seen from the preview

Don't miss anything!

bg1
pf3
pf4
pf5
pf8
pf9
pfa
pfd
pfe
pff

Partial preview of the text

Download California UST Service Technician Exam with Questions and Answers and more Exams Public Choice in PDF only on Docsity!

By December 22, 1998, all automatic line leak detectors installed on single-walled pressurized piping must be capable of: ANSWERV ¥ shutting down the pumping system An automatic tank gauge is capable of . ANSWERY ¥ Measuring diesel product temperature; Activating low level alarms for premium grade gasoline; Measuring product level of diesel product; When an automatic tank gauge is utilized for single-walled tank leak detection, it shall test the tank at least monthly after product delivery or when the tank is filled to within percent of the highest operating level during the previous month. ANSWERV V 10 When an automatic tank gauge is utilized for single-walled tank leak detection, it shall generate a post-test hard copy data report of the following information EXCEPT: ANSWERYV ¥ outside air temperature Approved cathodic protection methodologies include: ANS WERV ¥ sacrificial anodes; impressed current systems The following product piping requires cathodic protection. ANSWERV ¥ single-walled steel Cathodic protection systems must be inspected by a certified cathodic protection tester within months of installation. ANSWERV ¥ 6