Docsity
Docsity

Prepare for your exams
Prepare for your exams

Study with the several resources on Docsity


Earn points to download
Earn points to download

Earn points by helping other students or get them with a premium plan


Guidelines and tips
Guidelines and tips

California C10 Electrical Exam with Questions and Answers, Exams of Electrical Engineering

California C10 Electrical Exam with Questions and Answers Min receptacles in a garage ANSWER✓✓ 1 Mobile home service equipment shall be line of sight and no more than ____ from the exterior wall of the home ANSWER✓✓ 30' If a service conductor is over 300V but less than 600V, what is the minimum clearance of that service conductor if it runs in residential and commercial areas that are not subject to traffic? ANSWER✓✓ 15' A power meter must be a minimum of ____ feet away from any door, gas meter, or window opening. ANSWER✓✓ 3 A rod-type grounding electrode should have a minimum diameter of ANSWER✓✓ 5/8" Conductors entering buildings shall be protected: ANSWER✓✓ To the point of entrance A grounding electrode must be in contact with soil a minimum: ANSWER✓✓ 8' If a raceway has various conductors coming from different systems, then you should group each system separately every: ANSWER✓✓ 6' What is the maximum distance a service conductor can run over a roof? ANSWER✓✓ 6

Typology: Exams

2024/2025

Available from 02/15/2025

school-inspector
school-inspector 🇺🇸

2

(1)

4.5K documents

1 / 5

Toggle sidebar

This page cannot be seen from the preview

Don't miss anything!

bg1
pf3
pf4
pf5

Partial preview of the text

Download California C10 Electrical Exam with Questions and Answers and more Exams Electrical Engineering in PDF only on Docsity!

California C10 Electrical Exam with Questions and Answers Min receptacles in a garage ANSWERV V | Mobile home service equipment shall be line of sight and no more than from the exterior wall of the home ANSWERV ¥ 30! If a service conductor is over 300¥V but less than 600V, what is the minimum clearance of that service conductor if it runs in residential and commercial areas that are not subject to traffic? ANSWERVV 15° A power meter must be a minimum of feet away from any door, gas meter, or window opening. ANSWERV V 3 A rod-type grounding electrode should have a minimum diameter of ANSWERV V 5/8" Conductors entering buildings shall be protected: ANS WERV ¥ To the point of entrance A grounding electrode must be in contact with soil a minimum: ANSWERVV 8' If a raceway has various conductors coming from different systems. then you should group each system separately every; ANSWERV ¥ 6' What is the maximum distance a service conductor can run over a roof? ANSWERV V 6'