Docsity
Docsity

Prepare for your exams
Prepare for your exams

Study with the several resources on Docsity


Earn points to download
Earn points to download

Earn points by helping other students or get them with a premium plan


Guidelines and tips
Guidelines and tips

BICSI Technician HW #2: Telecommunications Cabling and Infrastructure, Exams of Telecommunications Engineering

A series of questions and answers related to bicsi technician hw #2, focusing on telecommunications cabling and infrastructure. It covers topics such as backbone cabling, patch cords, horizontal structured cabling, telecommunications spaces, and cable management. Useful for students preparing for the bicsi technician certification exam.

Typology: Exams

2024/2025

Available from 02/27/2025

tizian-kylan
tizian-kylan 🇺🇸

2.7

(21)

3.8K documents

1 / 7

Toggle sidebar

This page cannot be seen from the preview

Don't miss anything!

bg1
BICSI Technician HW #2 Questions &
Answer, 100% Correct 2025/2026
Grade A+
The function of which type of cable is to provide interconnections between equipment rooms and
telecommunications rooms?
: Backbone cable
The main components of backbone cabling are cabling pathways, cables, miscellaneous support
facilities and which of the following?
: Connection hardware
What is the maximum length of a patch cord?
: 16.4'
You are installing horizontal structured cabling in an open office environment with modular
furniture. You are using category 6A cabling. You have to terminate 22 cabling runs in each modular
furniture cluster of 11 units, and you are using MUTOAs. How many MUTOAs are required for this
application.
: 1
1
pf3
pf4
pf5

Partial preview of the text

Download BICSI Technician HW #2: Telecommunications Cabling and Infrastructure and more Exams Telecommunications Engineering in PDF only on Docsity!

BICSI Technician HW #2 Questions &

Answer, 100% Correct 2025/

Grade A+

The function of which type of cable is to provide interconnections between equipment rooms and telecommunications rooms? ✔: Backbone cable The main components of backbone cabling are cabling pathways, cables, miscellaneous support facilities and which of the following? ✔: Connection hardware What is the maximum length of a patch cord? ✔: 16.4' You are installing horizontal structured cabling in an open office environment with modular furniture. You are using category 6A cabling. You have to terminate 22 cabling runs in each modular furniture cluster of 11 units, and you are using MUTOAs. How many MUTOAs are required for this application. ✔: 1

How many transition points can you install in a horizontal cabling run? ✔: 1 What color represents 1st level backbone cross-connect in a telecommunications room? ✔: White What color represents the horizontal cabling cross-connect in a telecommunications room? ✔: Blue Which class of administration of a SCS addresses infrastructure with multiple sight or campuses? ✔: 4 You are installing an outside plant cable into a building entrance. The customer is not concerned about aesthetic appearance. They just want the cheapest and most easily maintained option. What type of cable entrance would you use? ✔: Aerial The main difference between an entrance facility and this room is that this room is generally considered to be floor-serving as opposed to building serving facilities. ✔: TR

✔: All Where should conduit ends be placed when a single piece of plywood is used as a backboard? ✔: On the left side The size of one rack unit is ✔: 1.75" The maximum length of flexible conduit is ✔: 20' The largest hand bender is what size? ✔: 1 - 1/4 trade size It is suggested that open cable supports be used for no more than how many cables? ✔: 50 What is the initial fill ratio factor of conduits when installing 2 cables? Assume straight runs with now degrees of bend. ✔: 31%

Open top cable supports should be installed to maintain a minimum of inches above ceiling tiles ✔: 3 What is the point where the service provider network ends and the customer network begins? ✔: Demarcation Point What is the maximum allowable horizontal cable length? ✔: 295' Which structured cabling topology places all network devices on one length of cable? ✔: Bus What type of system is used to extend cellular coverage into a building to provide adequate coverage throughout the inside of the building? ✔: DAS Which cable provides an interconnections between Telecommunications spaces? ✔: Backbone Cable

✔: Yellow Plywood SHOULD be installed on at LEAST walls in a TR ✔: 2 Plywood should be painted with at least coat/s of fire retardant paint. ✔: 2 If toggle bolts are used to hang plywood backboard, they should be spaced apart. ✔: 24" What are the common depths of equipment racks? ✔: 4" and 6" What type of conduit should not be used inside commercial buildings? ✔: PVC