Study with the several resources on Docsity
Earn points by helping other students or get them with a premium plan
Prepare for your exams
Study with the several resources on Docsity
Earn points to download
Earn points by helping other students or get them with a premium plan
Community
Ask the community for help and clear up your study doubts
Discover the best universities in your country according to Docsity users
Free resources
Download our free guides on studying techniques, anxiety management strategies, and thesis advice from Docsity tutors
A comprehensive set of 200 questions and answers related to oil burner systems, covering topics such as fuel types, combustion, draft, ignition systems, and maintenance. It is a valuable resource for individuals studying or working in the field of oil burner technology.
Typology: Exams
1 / 28
This page cannot be seen from the preview
Don't miss anything!
In an electric circuit for the wattage to remain the same if the voltage drops, the amperage must - ANS:->>> Increase Atomizing type burners were designed to burn which type of fuel – ANS:->>> Type 2 fuel oil Pour point problems with outside above ground fuel tanks can be partially relieved by - ANS:->>> Reducing the pour point of No. 2 fuel oil by blending it with No. 1 fuel oil. A fuel oil storage tank cannot be installed - ANS:->>> In the furnace room with 5' of heating unit. The primary purpose of a fuel pump on a high-pressure burner is to - **ANS:-
Deliver oil at a constant and regulated pressure to the nozzle** If the vacuum reading is substantially above the calculated reading, (with the burner running) the cause may be - ANS:->>> Plugged fuel filter, Kinked oil supply line, Check valve sticking
With most new flame retention burners, the motor speed is - ANS:->>> 3450 To check for proper nozzle line cut-off, the pressure gauge is installed in the - ANS:->>> Nozzle Port Fuel units are generally set at the factory at - ANS:->>> 100psi The oil burner nozzle in a high-pressure burner performs the following functions
gauge in – ANS:->>> Inches of water column The most important draft measurement to be taken on any oil-fired unit is - ANS:->>> The draft at the breech The draft over the fire The proper location to install a draft inducer is - ANS:->>> •In the flue pipe between the draft regulator and the chimney Using combustion test instruments to measure the composition and temperature of the flue gas as they leave the heating unit will indicate the - ANS:->>> Steady state efficiency The holes that are provided in the flue pipe for combustion testing must be - ANS:->>> •Between the heating unit and the draft regulator When using a pump type smoke tester, ten full strokes are necessary to - ANS:-
•Draw the proper amount of flue gas past the paper The fluid in a CO2 tester is good for about how many tests? - ANS:->>> For about 400 tests When applying current through a conductor that is wound in coil, the magnetic lines of force created are used in - ANS:->>> •Solenoid valve
. Relay
ANS:->>> •a. Reduce the amount of air for combustion The fan-limit control on a warm air unit is used to: - ANS:->>> •Shut off the burner at a predetermined temperature
Line voltage and wired in series with the primary control Low voltage thermostats are more widely used than line voltage thermostats because - ANS:->>> They are more sensitive to ambient temperature When a thermostat appears to be out of calibration it is important to first - ANS:->>> Be sure the thermostat is level Check to see that the hole behind the thermostat is sealed off properly .Be sure that the thermostat is acclimated to the room temperature The primary control must be capable of - ANS:->>> •Reacting to the absence of flame
-. Controlling the ignition and motor
Short cycling of the burner can be caused by - ANS:->>> •The heat anticipator not set properly
Before lowering the temperature of a hot water boiler, consideration must be given to the - ANS:->>> Design of the heating The boiler or furnace is not the only source of heat loss. The heating system can lose heat through - ANS:->>> •insulated steam pipes
Drop and hold at 80% Power venters that are installed inside the structure should be - ANS:->>> Mounted as close to the outside as possible When the installation instructions call for a draft regulator with a power vent system, it should be installed - ANS:->>> •a. Between the boiler or furnace and the power venter
Which of the following is considered the better chimney? - ANS:-
•Galvanized flue pipe Air is composed of oxygen and nitrogen in what percentages? - ANS:->>> 21 and 79 Before installing a new nozzle, the service technician should - ANS:->>> •Flush out the nozzle line and adapter Pulsating oil pump pressure is caused by - ANS:->>> •Air leaks in the suction line
. Kinked oil supply line
Induce a current flow in the conductor When installing a power vent system, you must - ANS:->>> Follow the manufacturer's installation guide To test a stack mounted primary control safety you should - ANS:->>> Remove the unit from the flue pipe An advantage of power venting is - ANS:->>> •More positive control of draft What is the approximate safety timing of stack mounted primary controls - ANS:->>> 60 to 90 seconds The best way to adjust an oil burner is - ANS:- by combustion testing equipment What is the correct procedure for performing a combustion efficiency test? - ANS:->>> •Draft
What two major components make up fuel oil? - ANS:->>> hydrogen and carbon Incomplete combustion causes - ANS:->>> soot and smoke Poor efficiency Low CO
furnaces offer over older units: - ANS:->>> •Economical operation
The following are important factors that affect chimney performance: - ANS:->>> Wind Burner firing rate Air flows caused by house exhaust fan The flue connection from the outlet of the boiler or furnace to the chimney base should as a s possible to maintain good draft. - ANS:->>> short A common source of air leakage into the chimney is: - ANS:->>> Loose-fitting clean-out door at base of chimney What is the minimum net temperature needed at the breeching of an oil-fired appliance to prevent condensation problems - ANS:->>> 285F The main parts of the chimney venting system used in oil heated houses are: - ANS:->>> •Chimney
Draft proving switch In the "sealed and insulated venting system" the draft regulator is: - ANS:->>> Removed The post-purge control on power side wall venting systems is designed to - ANS:->>> • Prevent odors and nozzle fouling When installing a side wall venting system, the vent outlet must be at least above ground - ANS:->>> 1ft A "sealed and insulated chimney system" requires: - ANS:->>> The flue pipe be increased one size The draft inducer fan on a side wall venting system should be installed: - ANS:- Close to the outside wall Power chimney venting: - ANS:->>> •Uses the existing chimney